Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP22-0013
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/28/2022 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 04/14/2022 | JVINCEN1 | FIRE | REVIEW | Approved | |
| 04/15/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: Lamplighter Chabad Day School Development Package (2nd Review) DP22-0013 TRANSMITTAL DATE: April 15, 2022 DUE DATE: April 22, 2022 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is January 31, 2023 2-06.3.0 FORMAT REQUIREMENTS CONTENT REQUIREMENTS 1. This comment was not addressed correctly, the north section line is at Grant not Pima. COMMENT: 2-06.4.4.C – The section corners labeled on the location map are not correct. The north section line should be at Grant, the east section line should be at Alvernon and the west should be at Country Club. 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. 2-06.4.7.A - Zoning and Land Use Notes 2. This comment was not fully addressed. Per UDC TABLE 4.8-4: PERMITTED USES - COMMERCIAL AND MIXED USE ZONES, C-2 Zone, Civic Land Use Group With Land Use Class/Type: Educational Use: Elementary and Secondary is subject to Use Specific Standard 4.9.3.D.1 – 7. Per AM Section 2-06.4.7.A.4 provide the Use Specific Standard with Zoning Note 3. COMMENT: 2-06.4.7.A.4 Zoning Note 3 clarify what the proposed use is. Based on the vehicle parking space requirements you are proposing two (2) separate uses, daycare and education. Also depending on the using provide all applicable Use Specific Standards that apply. 2-06.4.8 - Existing Site Conditions The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 3. This comment was not addressed. The alley that you reference in your comment response was abandoned, see Assessor’s Record Map found at: https://www.asr.pima.gov/ParcelData/Map/Arm/MP04/M04095_B15.PDF. If you are going to access this parking across the adjacent parcel provide a recorded document, easement or agreement that allows this access. COMMENT: 2-06.4.9.H.5 – Clearly demonstrate that at a minimum a 20’-0” wide two-way access lane is maintained that provides access to the southwest parking area. 4. This comment was not addressed. There is nothing shown on the plan. COMMENT: 2-06.4.9.H.5 – Demonstrate that the requires of UDC Article 7.4.6.H.1 are maintained around the proposed playground. If you have any questions about this transmittal, please contact Nicholas Ross at Nocholas.Ross@tucsonaz.gov. To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 04/15/2022 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | Email from: COTDSDPermits To: Rhonda Fri 4/15/2022 3:23 PM REVIEW NOTICE Returned for Corrections: DP22-0013 DESCRIPTION: Site - Lamplighter Chabad Day School. New classrooms in existing building, wall. 3830 E BELLEVUE ST Fee Balance: $0 (zero) Thank you for the payment. YOUR NEXT STEPS 1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab to see different sections - Reviews section - click on REVIEW DETAILS - Documents section - click on VIEW 2. Title your THIRD submittal documents accordingly, example: 3_Comment Response Letter 3. UPLOAD A RESUBMITTAL to Filedrop: 1) Comment Response Letter (your response to REQUIRES CHANGE comments) 2) Plan Set (all pages, full set, even if no changes were made) 3) Any other documents requested by review staff - FILEDROP: https://docs.tucsonaz.gov/Forms/tucsonpermitapp - "Existing Application" - "Permit Number" field: enter the number (and any notes for our staff) - Select "PLANS" for all documents Thank you. Sharon Beasley, Certified Permit Specialist City of Tucson, Planning and Development Services Email: COTDSDpermits@TucsonAz.gov |