Permit Number: DP22-0005
Parcel: 11306150E

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP22-0005
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/08/2022 SBEASLE1 START PLANS SUBMITTED Completed
08/12/2022 AWARNER1 LANDSCAPE REVIEW Reqs Change CDRC TRANSMITTAL
TO: Planning and Development Services Department, Plans Coordination
FROM: Anne Warner, RLA
PDSD Landscape/Native Plant Preservation Section

PROJECT: Salad & Go
ACTIVITY NO: DP22-0005, 2nd submital
Address: 1919 E Ft Lowell Rd
Zoning: C-1/2
Existing Use: Car wash, vacant lot
Proposed Use: Food Service

TRANSMITTAL DATE: August 12, 2022
DUE DATE: August 31, 2022
COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Landscape Review Section comments were addressed.
This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting.
1. The landscape and water harvesting plans are not readable, there are many graphic conflicts. Please simplify plans by screening back or turning off layers for readability
2. The landscape plan and the site plan base do not match. It is difficult to tell what is proposed versus what is in the future. Please revise.
3. The grading limits on the site plan are incorrect if there are water harvesting basins proposed along Campbell and Ft. Lowell.
4. If construction is proposed along Campbell and Ft. Lowell, in this case detention basins, then a 10’ landscape border is also required along the streets.
5. Please add a note to landscape plans that if landscape and water harvesting in the future right of way must be removed because of road improvements, a new 10’ landscape border and water harvesting is required along Campbell Ave.
6. Please revise maintenance reference on landscape plan to the correct page number.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package

YOUR NEXT STEPS: Submit documents to the Filedrop
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
Select "Existing Application"
1) Comment Response Letter (your response to
the reviewer's Requires changes comments)
2) Plan Set (or individual sheets)
3) Any other items requested by review staff

If you have any questions, please contact me at anne.warner@tucsonaz.gov
09/12/2022 SBLOOD1 ENGINEERING REVIEW Reqs Change 1. See previous comment 1 - The way we have been interpreting the new retention/detention manual is as such: when a site like this one is redeveloped and the existing structure demolished and site is regraded and repaved then we consider the pre-development conditions as vacant/undisturbed. Please revise the detention calculations to reflect this. Note - the retention and water harvesting look good now.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
09/15/2022 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change email from: COTDSDPermits
to: lisa bowers
Sept. 15, 2022

Returned for Corrections: DP22-0005
Site/Grading - Salad and Go. Restaurant.

Fee Balance: $0 (zero)

YOUR NEXT STEPS
1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on the blue tab
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

2. Title your FOURTH submittal documents accordingly, example: 4_Comment Response Letter

3. UPLOAD documents to Filedrop:
- Comment Response Letter (your response to REQUIRES CHANGE comments)
- Plan Set (all pages, full set, even if no changes were made)
- Documents requested by review staff

FILEDROP
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- "Existing Application"
- "Permit Number" field: enter the number (and any notes for our staff)


Sharon Beasley
Certified Permit Specialist

City of Tucson, Planning & Development Services Dept.
Email: COTDSDpermits@TucsonAz.gov
(for development packages, land splits, Thursday Presubmittal meetings)
Email: PDSDinquiries@TucsonAz.gov
(for building permits)