Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP22-0005
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/17/2022 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 06/15/2022 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 06/16/2022 | AWARNER1 | LANDSCAPE | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Planning and Development Services Department, Plans Coordination FROM: Anne Warner, RLA PDSD Landscape/Native Plant Preservation Section PROJECT: Salad & Go ACTIVITY NO: DP22-0005, 2nd submital Address: 1919 E Ft Lowell Rd Zoning: C-1/2 Existing Use: Car wash, vacant lot Proposed Use: Food Service TRANSMITTAL DATE: June 16, 2022 DUE DATE: June 13, 2022 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Landscape Review Section comments were addressed. This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting. 1. General Note - UDC 2-10.4.1 Identification and Descriptive Data - All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan. 2. General Note - Ensure that Zoning and Engineering comments are addressed prior to landscape section approval. 3. This comment was not adequately addressed – engineer’s plans and landscape plans do not match. Please label the existing and future rights of way for Campbell Ave and Ft. Lowell UDC 7.6.4.C.2.a. 4. Water harvesting basins and landscape must be behind the future right of way. Up to 5’ is allowed in the right of way with approval from the Department of Transportation and Mobility. Contact david.marhefka@tucsonaz.gov 5. This comment was not adequately addressed, Dalea capitata Sierra Gold is a ground cover with a height of 1’. Please choose another species to provide a minimum 30” screen. A 30” continuous vegetative screen (or wall) is required to screen parking areas along Campbell Ave. Plants shown on plan are not sufficient in quantity to provide a screen. 6. This comment was not adequately addressed, label the existing water for irrigation only. Please indicate the installation of a private submeter if a separate irrigation meter is not being provided. UDC Technical Standards 4-01.6.1.A.1. 7. Please add that shearing shrubs is not permitted. Provide a maintenance schedule for the landscape and irrigation for this project. UDC 2-10-4.2.A.4., please be specific. 8. This comment was not adequately addressed - The grading and water harvesting do not match. Indicate Basin D on the grading plan and provide spot elevations. Bare dirt is not acceptable, nor is D.G. Grading, hydrology, and landscape plans must be integrated to make maximum use of site storm water runoff for supplemental on-site irrigation purposes. The landscape plan shall indicate use of all runoff, from individual catch basins around single trees to basins accepting flow from an entire vehicular use area or roof area. UDC 7.6.6.C.2. The landscape, water harvesting, and grading plans must match. 9. This comment was not adequately addressed - Identify the point of drainage off roof areas, amount of flow, and disposition of flow. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package YOUR NEXT STEPS: Submit documents to the Filedrop https://docs.tucsonaz.gov/Forms/tucsonpermitapp Select "Existing Application" 1) Comment Response Letter (your response to the reviewer's Requires changes comments) 2) Plan Set (or individual sheets) 3) Any other items requested by review staff If you have any questions, please contact me at anne.warner@tucsonaz.gov |
| 06/23/2022 | DSTIFFE1 | COT NON-DSD | TRAFFIC | Approved | |
| 07/28/2022 | SBLOOD1 | ENGINEERING | REVIEW | Reqs Change | 1. With the new retention/detention manual being less than an acre doesn't exempt you from detention requirements. Also existing conditions need to be calculated from Pre-development conditions. Please show balanced basin detention for the site. 2. Detention/retention have to work for phase 1 in this development and can't rely on a future phase. 3. Drainage area D1 and D2 show no runoff being captured in retention. All runoff in a given drainage area doesn't need to be captured but each one needs to be capturing something if possible. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
| 08/01/2022 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | email from: COTDSDPermits to: lisa bowers Mon 8/1/2022 3:28 PM REVIEW NOTICE Returned for Corrections: DP22-0005 Site/Grading - Salad and Go. Restaurant. Fee Balance: $0 (zero) YOUR NEXT STEPS 1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab - Reviews section - click on REVIEW DETAILS - Documents section - click on VIEW 2. Title your THIRD submittal documents accordingly, example: 3_Comment Response Letter 3. UPLOAD A RESUBMITTAL to Filedrop: - Comment Response Letter (your response to REQUIRES CHANGE comments) - Plan Set (all pages, full set, even if no changes were made) - Any other documents requested by review staff FILEDROP https://docs.tucsonaz.gov/Forms/tucsonpermitapp - "Existing Application" - "Permit Number" field: enter the number (and any notes for our staff) - Select "PLANS" for all documents Sharon Beasley, Certified Permit Technician City of Tucson, Planning & Development Services Dept. Email: COTDSDpermits@TucsonAz.gov (for development packages, land splits, Thursday Presubmittal meetings) Email: PDSDinquiries@TucsonAz.gov (for building permits) |