Permit Review Detail
Review Status: Completed
Review Details: DEV PKG
Permit Number - DP22-0001
Review Name: DEV PKG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/28/2022 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 01/28/2022 | SBEASLE1 | ENGINEERING | REVIEW | Reqs Change | Review comment (copied from the OK to Submit): 1. This site is within a mapped City of Tucson floodplain. A floodplain use permit is required. Loren Makus loren.makus@tucsonaz.gov |
| 02/03/2022 | JVINCEN1 | FIRE | REVIEW | Approved | |
| 02/07/2022 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 02/24/2022 | LSHAMIS1 | ZONING | REVIEW | Reqs Change | Zoning has done a cursory review and site plan appears to be consistent with the preliminary development package submitted for the Zoning Examiner Special Exception Procedure (T22SE00012) however Zoning cannot conduct a substantive review until the Special Exception is approved. |
| 02/25/2022 | AWARNER1 | LANDSCAPE | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Planning and Development Services Department, Plans Coordination FROM: Anne Warner, RLA PDSD Landscape/Native Plant Preservation Section PROJECT: Tucson Water Well ACTIVITY NO: DP21-0001 Address: 9432 E 26th St Zoning: R-1 Existing Use: Well Proposed Use: Well TRANSMITTAL DATE: February 25, 2022 DUE DATE: February 15, 2022 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Landscape Review Section comments were addressed. This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting. 1. Ensure that Zoning and Engineering comments are addressed prior to landscape section approval. 2. The Unified Development Code (UDC) requires all new development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10. The plan shows the required 10’ street landscape border (which should extend to the east property line), but no vegetation is shown. 3. A 6’ wall, not chainlink, is required adjacent to residential uses, UDC Table 7.6.4-1. 4. Please provide all landscape calculations on the landscape plan Admin. Manual 2-10-4.2.A.2.c and landscape borders, UDC Technical Standards 2-10.4.2.f & g. 5. An irrigation plan and specifications are required per UDC Administration Manual 2-10.4.2.C and Technical Standards Manual Section 4-01.4.2, Irrigation Standards. 6. Please add/call out soil moisture gauge/tensiometers and rain shut-off device on irrigation plans and details. UDC Tech Standards 4.01-2.A. 7. Please indicate the installation of a private submeter if a separate irrigation meter is not being provided. UDC Technical Standards 4-01.6.1.A.1. 8. Please add a detail to show depressed (6-9”) landscape areas to collect rainwater or indicate with notes. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package YOUR NEXT STEPS: Submit documents to the Filedrop https://docs.tucsonaz.gov/Forms/tucsonpermitapp Select "Existing Application" 1) Comment Response Letter (your response to the reviewer's Requires changes comments) 2) Plan Set (or individual sheets) 3) Any other items requested by review staff If you have any questions, please contact me at anne.warner@tucsonaz.gov |
| 03/01/2022 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | Email from: COTDSDPermits To: Cathy Russo Tue 3/1/2022 1:42 PM REVIEW NOTICE Returned for Corrections: DP22-0001 DESCRIPTION: Site: Wellsite E-016A SCADA Upgrade. 9434 E 26TH ST Fee Balance: $0 (zero) Thank you for the payment. YOUR NEXT STEPS 1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab to see different sections - Reviews section - click on REVIEW DETAILS - Documents section - click on VIEW 2. UPLOAD A RESUBMITTAL and include: 1) Comment Response Letter (your response to REQUIRES CHANGE comments) 2) Plan Set (all pages, full set, even if no changes were made) 3) Any other documents requested by review staff Please title your SECOND submittal documents according to this example: 2_Comment Response Letter FILEDROP: https://docs.tucsonaz.gov/Forms/tucsonpermitapp - Select "Existing Application" - In the "Permit Number" field, enter the number and, if applicable, any notes for our staff - Select "PLANS" for all documents for quicker downloading of your documents on our end Thank you. Sharon Beasley, Building Permit Specialist City of Tucson, Planning and Development Services Email: COTDSDpermits@TucsonAz.gov |