Permit Number: DP21-0362
Parcel: 113071300

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP21-0362
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/02/2022 SBEASLE1 START PLANS SUBMITTED Completed
10/14/2022 AWARNER1 LANDSCAPE REVIEW Reqs Change CDRC TRANSMITTAL
TO: Planning and Development Services Department, Plans Coordination
FROM: Anne Warner, RLA
PDSD Landscape/Native Plant Preservation Section

PROJECT: The Hedrick
ACTIVITY NO: DP21-0362, 3rd submittal
Parcel: 113-07-1300
Zoning: R-2
Existing Use: SFR
Proposed Use: Multi-family residential

TRANSMITTAL DATE: October 14, 2022
DUE DATE: September 27, 2022
COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Landscape Review Section comments were addressed.
This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting.

1. The referenced development package DP18-0239 has been withdrawn, and has no effect on the current DP. The entire site requires bringing up to Code because of the expansion. The Unified Development Code (UDC) requires all new development or an expansion of less than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10.

2. This comment was not addressed, there is no NPPO approved for T21CM01383 - A Native Plant Preservation Plan, Section 7.7.4, is required to be submitted and approved. The new landscape plan shall include all the mitigation plants that are required when native trees are removed without permits. Sections 7.7.3.D.3 & .4 of the Unified Development Code (UDC) and Admin. Manual Section 2-11.0.0 prior to Grading Plan approval.

3. This comment was not adequately addressed – The landscape shown on T21CM01383 has not yet been installed per plans. Please add T21CM01383 to the plans indicating to inspectors to look at that plan for the street landscape border. New calculations are required.

4. This comment was not adequately addressed - Please indicate the installation of a private submeter if a separate irrigation meter is not being provided. UDC Technical Standards 4-01.6.1.A.1.

5. This comment was not adequately addressed – The landscape areas shall be depressed 6-8” before d.g. is placed.


RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package

YOUR NEXT STEPS: Submit documents to the Filedrop
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
Select "Existing Application"
1) Comment Response Letter (your response to
the reviewer's Requires changes comments)
2) Plan Set (or individual sheets)
3) Any other items requested by review staff

If you have any questions, please contact me at anne.warner@tucsonaz.gov
10/17/2022 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change email from: COTDSDPermits
To: Peter Salonga
10/17/2022

REVIEW NOTICE

Returned for Corrections: DP21-0362
Site/Grading/Floodplain - The Hedricks. Add two units to an existing two-unit development.
1613 E HEDRICK DR

Fee Balance: $0 (zero) Thank you for the payment.

YOUR NEXT STEPS
1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on the blue tab
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

2. Title your FOURTH submittal documents accordingly, example: 4_Comment Response Letter

3. UPLOAD documents to Filedrop:
- Comment Response Letter (your response to REQUIRES CHANGE comments)
- Plan Set (all pages, full set, even if no changes were made)
- Documents requested by review staff

FILEDROP
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- "Existing Application"
- "Permit Number" field: enter the number (and any notes for our staff)


Sharon Beasley, Certified Permit Specialist

City of Tucson, Planning & Development Services Dept.
Email: COTDSDpermits@TucsonAz.gov