Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: DP21-0353
Parcel: 12908001A

Address:
1695 E 21ST ST

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP21-0353
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/11/2022 SBEASLE1 START PLANS SUBMITTED Completed
05/11/2022 SBEASLE1 ENGINEERING REVIEW Reqs Change (The review comments below are from the OK to Submit)

1. Revise the water harvesting basin to provide a depth between 6 and 9 inches per the updated detention/retention manual.
2. Provide a water harvesting budget plan.
3. Since access to this site is from the adjacent parcel, provide a development package for the entire site.

Loren Makus
loren.makus@tucsonaz.gov
05/12/2022 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change
05/12/2022 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Wesco Storage Lot - Expansion
Development Package (1st Review)
DP21-0353

TRANSMITTAL DATE: May 12, 2022

DUE DATE: May 18, 2022

COMMENTS: Resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is April 26, 2023.

2-06.2.0 APPLICATION SUBMITTAL REQUIREMENTS

1. COMMENT: 2-06.2.4 – As DP13-0142 was never finaled and was withdrawn with open inspections this DP will need to show all proposed work shown on DP13-0142. Until this work is provided Zoning cannot provide final comments.

CONTENT REQUIREMENTS

2. COMMENT: 2-06.4.3 – Provide the development package case number, DP21-00353, adjacent to the title block on all sheets.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

3. COMMENT: 2-06.4.9.A – As this site is made up of two (2) parcels, 129-08-001A & 129-08-002C, a lot combination is required. Provide a copy of the approved Pima County Combo Request form with the next submittal.

4. COMMENT: 2-06.4.9.F - All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined.

5. COMMENT: 2-06.4.9.H.2 – If applicable show sight visibility triangles on the plan.

6. COMMENT: 2-06.4.9.H.5.a – As the vehicle parking lease agreement was only for two (2) vehicle parking spaces and no spaces are shown on this DP a Board of Adjustment for Variance is required.

7. COMMENT: 2-06.4.9.H.5.c – Show the required loading zone on the plan.

8. COMMENT: 2-06.4.9.H.5.d – The bicycle parking calculation is not correct. As bicycle parking is based on gross floor area and there are not buildings proposed zero long-term spaces are required. If you are going to provide a long-term space show the location on the plan and provided a detail that demonstrates that UDC Article 7.4.9.D is met.

9. COMMENT: 2-06.4.9.O – Based on the Zoning Administrators letter dated September 23, 2012 show the 20’ front street perimeter yard setback on the plan and clearly delineate the limits of the storage and demonstrate that the storage will not encroach into the 20’ street setback.

10. COMMENT: Additional comments maybe forth coming once all requested information has been provided.

If you have any questions about this transmittal, please contact Nicholas Ross at Nocholas.Ross@tucsonaz.gov.

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
05/24/2022 JPEELDA1 FIRE REVIEW Approved
05/31/2022 AWARNER1 LANDSCAPE REVIEW Approved
06/02/2022 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Email from: COTDSDPermits
To: Richard
Thu 6/2/2022 2:22 PM

REVIEW NOTICE
Returned for Corrections: DP21-0353

DESCRIPTION: Site/Grading - WESCO, new storage lot. 1697 E 21ST ST

Fee Balance: $0 (zero) Thank you for the payment.

YOUR NEXT STEPS
1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

2. Title your SECOND submittal documents accordingly, example: 2_Comment Response Letter

3. UPLOAD A RESUBMITTAL to Filedrop:
- Comment Response Letter (your response to REQUIRES CHANGE comments)
- Plan Set (all pages, full set, even if no changes were made)
- Any other documents requested by review staff

- FILEDROP - Might not be available
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- "Existing Application"
- "Permit Number" field: enter the number (and any notes for our staff)
- Select "PLANS" for all documents

Thank you.
Sharon Beasley, Certified Building Technician

City of Tucson, Planning & Development Services Dept.
Email: COTDSDpermits@TucsonAz.gov
(for development packages, land splits, Thursday Presubmittal meetings)

Email: PDSDinquiries@TucsonAz.gov
(for building permits and all other subjects)