Permit Number: DP21-0344
Parcel: 120052810

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP21-0344
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/18/2022 SBEASLE1 START PLANS SUBMITTED Completed
04/05/2022 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Take Five Oil Change Facility – 850 W Irvington St.
Development Package (2nd Review)
DP21-0344

TRANSMITTAL DATE: April 5, 2022

DUE DATE: April 18, 2022

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is December 14, 2022.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

1. This comment was not addressed. Per UDC TABLE 4.8-4: PERMITTED USES - COMMERCIAL AND MIXED-USE ZONES, C-2 Zone the applicable Use Specific Standard for Automotive Minor Service & Repair is 4.9.13.E. COMMENT: 2-06.4.7.A.4 – The use specific standards listed under Zoning and Land Use Notes 4 are not correct. Review UDC TABLE 4.8-4: PERMITTED USES - COMMERCIAL AND MIXED-USE ZONES and provided the correct standards.

If you have any questions about this transmittal, please contact Nicholas Ross at Nocholas.Ross@tucsonaz.gov

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
04/18/2022 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
05/06/2022 AWARNER1 LANDSCAPE REVIEW Approved
05/16/2022 SBLOOD1 ENGINEERING REVIEW Reqs Change 1. See previous sheet 3 comment 10 - Please provide and label all necessary pedestrian crosswalk paths shown by detail 7 sheet 6. Paths should tie to adjacent sidewalks, connect parking to buildings, and building to trash enclosure. The site plan is still not showing where the pedestrian ADA striping is located on site. Please clarify and revise as necessary.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
05/19/2022 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Email from: COTDSDPermits
To: Linda Thompson
Thu 5/19/2022 9:57 AM

REVIEW NOTICE
Returned for Corrections: DP21-0344

DESCRIPTION: Site/Grading/SWPPP - Take Five Oil Change Facility. 850 W IRVINGTON RD

Fee Balance: $0 (zero) Thank you for the payment.

YOUR NEXT STEPS
1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

2. Title your third submittal documents accordingly, example: 3_Comment Response Letter

3. UPLOAD A RESUBMITTAL to Filedrop:
- Comment Response Letter (your response to REQUIRES CHANGE comments)
- Plan Set (all pages, full set, even if no changes were made)
- Any other documents requested by review staff

- FILEDROP:
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- "Existing Application"
- "Permit Number" field: enter the number (and any notes for our staff)
- Select "PLANS" for all documents

Thank you.

Sharon Beasley, Certified Building Technician

City of Tucson, Planning & Development Services Dept.
Email: COTDSDpermits@TucsonAz.gov
(If regarding development packages, land splits, Thursday Presubmittal meetings)

Email regarding building permits and all other subjects: PDSDinquiries@TucsonAz.gov