Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP21-0343
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/25/2022 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 08/10/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: Walk-In Cooler Addition – Mexico Lindo Development Package (3rd Review) DP21-0343 TRANSMITTAL DATE: August 10, 2022 DUE DATE: August 17, 2022 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is January 4, 2023. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 1. This comment was not addressed. The provided detail does not address UDC Articles 7.4.9.B.1.e, 7.4.9.B.2.b, & .f. The provided detail does not address the requirements of UDC Article 7.4.9.D Long-term Bicycle Parking. “BIKE RACKS” do not appear to meet the requirements of UDC Articles 7.4.9.B, .C & .D. A bike rack cannot meet the requirements for long-term bicycle parking. Provide a detail for both the short- & long-term bicycle parking that demonstrates that the requirements of UDC Articles 7.4.9.B, .C & .D are met. COMMENT: 2-06.4.9.H.5.d – Provide a short- & long-term bicycle parking space calculation on the plan. At a minimum per UDC Table 7.4.8-1: Minimum Required Bicycle Parking Spaces, RETAIL TRADE USE GROUP, Retail Trade Uses Less Than 50,000 sq. ft. GFA 2 short- & 2 long-term spaces are required. If you have any questions about this transmittal, please contact Nicholas Ross at Nicholas.Ross@tucsonaz.gov. To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 08/31/2022 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | EMAIL FROM: COTDSDPermits To: Talbott Denny 08/31/2022 Returned for Corrections: DP21-0343 SITE - Mexico Lindo. Addition of detached (pre-built) walk-in cooler on top of existing concrete pad. 50 W VALENCIA RD Fee Balance: $0 (zero) Thank you for the payment. YOUR NEXT STEPS 1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab - Reviews section - click on REVIEW DETAILS - Documents section - click on VIEW 2. Title your FOURTH submittal documents accordingly, example: 4_Comment Response Letter 3. UPLOAD documents to Filedrop: - Comment Response Letter (your response to REQUIRES CHANGE comments) - Plan Set (all pages, full set, even if no changes were made) - Documents requested by review staff FILEDROP https://docs.tucsonaz.gov/Forms/tucsonpermitapp - "Existing Application" - "Permit Number" field: enter the number (and any notes for our staff) Sharon Beasley, Certified Permit Technician City of Tucson, Planning & Development Services Dept. Email: COTDSDpermits@TucsonAz.gov (for development packages, land splits, Thursday Presubmittal meetings) Email: PDSDinquiries@TucsonAz.gov (for building permits) |