Permit Number: DP21-0330
Parcel: 10819019H

Address:
735 E WETMORE RD

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP21-0330
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/05/2022 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Kentucky Fried Chicken @ 735 E Wetmore Rd
Development Package (1st Review)
DP21-0330

TRANSMITTAL DATE: January 5, 2022

DUE DATE: January 11, 2022

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is December 06, 2022.

2-06.2.0 APPLICATION SUBMITTAL REQUIREMENTS

1. COMMENT: 2-06.2.4 – Remove development package DP15-0207 from this plan set.

2-06.3.0 FORMAT REQUIREMENTS

2. COMMENT: 2-06.3.7 - A small, project-location map shall be provided in the upper right corner of the cover sheet. The provided location map on sheet 1 is not readable and not in the correct location.

CONTENT REQUIREMENTS

3. COMMENT: 2-06.4.1 - The name, mailing and email addresses, and phone number of the primary property owner of the site, the developer of the project, shall be provided on the right half of the cover sheet.

4. COMMENT: 2-06.4.2.D - The page number and the total number of pages in the package (i.e., sheet xx of xx) shall be provided within the title block.

5. COMMENT: 2-06.4.3 – Provide the development package case number, DP21-0330, adjacent to the title block on all sheets.

As the location map shown on sheet one is unreadable the following 4 comments will need to be addressed:

6. COMMENT: 2-06.4.4 - The project-location map to be located on the first sheet of the development package in the upper right corner, shall cover approximately one square mile, be drawn at a minimum scale of three-inch equals one mile, and provide the following information.

7. COMMENT: 2-06.4.4.A – Show the subject property approximately centered within the one square mile area;
8. COMMENT: 2-06.4.4.B - Identify major streets and regional watercourses within the square mile area and all streets that abut the subject property; and,

9. COMMENT: 2-06.4.4.C - Section, township, and range; section corners; north arrow; and the scale will be labeled.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

10. COMMENT: 2-06.4.7.A.6.a – As 1st Ave is designated on the COT MS&R map as an Arterial Street provide a general note on the plan stating “THIS PROJECT IS DESIGNED TO MEET THE OVERLAY ZONE(S) CRITERIA, UDC ARTICLE 5.4 MAJOR STREETS AND ROUTES SETBACK ZONE (MS&R).”

2-06.4.7.A.8 - For development package documents provide:

11. COMMENT: 2-06.4.7.A.8.d - When the proposed site is part of a larger site, the calculations encompass the entire site, whether existing or proposed. If the project is being phased, calculations must show that, at each phase, requirements are being met.

2-06.4.8 - Existing Site Conditions
The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided.

12. COMMENT: 2-06.4.8.C - The following information regarding 1st Ave and Wetmore Rd: dimensioned width of paving, curbs, curb cuts, and sidewalks.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

13. COMMENT: 2-06.4.9.F - All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined.

14. COMMENT: 2-06.4.9.H.5.a – As vehicle parking spaces are being removed from the site with the construction of the new refuse enclosure provide a revised vehicle parking space calculation on the plan. This calculations shall include the number of spaces required (include the ratio used) and the number provided, including the number of spaces required and provided for the physically disabled. This calculation includes the entire site, see comment 11.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov.

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
01/07/2022 AWARNER1 LANDSCAPE REVIEW Needs Review
01/21/2022 JVINCEN1 FIRE REVIEW Approved john vincent
john.vincent@tucsonaz.gov
5203495581
01/24/2022 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Email from: COTDSDPermits
To: Bethel.DelRiego
Mon 1/24/2022 9:29 AM

REVIEW NOTICE
Returned for Corrections: DP21-0330

DESCRIPTION: Site - Kentucky Fried Chicken. Convert existing restaurant to a new restaurant. 735 E WETMORE RD

FEE BALANCE: $ 264.00
Please pay at a minimum, the REVIEW category fees.
A payment is required before your next submittal.

ONLINE PAYMENT
If amount doesn't match "Fees Due", check back in a few hours
https://www.tucsonaz.gov/pdsd/fees
1- Click on: Pay Planning & Permit Fees
2- Enter Permit Nbr, example: dp20-0000
(not case-sensitive but a hyphen-dash- is needed)
3- Business/Individual Name: Leave this field blank
4- "Continue"
5- In the Pay column - check the boxes
6- "Continue"

YOUR NEXT STEPS
1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab to see different sections
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

2. UPLOAD A RESUBMITTAL and include:
1) Comment Response Letter (your response to REQUIRES CHANGE comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

Please title your SECOND submittal documents according to this example: 2_Comment Response Letter

FILEDROP for your Resubmittal
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- Select "Existing Application"
- In the "Permit Number" field, enter the number and, if applicable, any notes for our staff
- Select for documents "PLANS" for quicker downloading of your documents on our end


Thank you.
Sharon Beasley, Building Permit Specialist

City of Tucson, Planning and Development Services
Email: COTDSDpermits@TucsonAz.gov
12/13/2021 SBEASLE1 START PLANS SUBMITTED Completed
12/13/2021 SBEASLE1 ENGINEERING REVIEW Reqs Change (Review comments from the OK to Submit)

1. Clearly indicate all proposed improvements on an improvement plan. Show the details of the building expansion.

2. Show that the solid waste enclosure meets the requirements of Technical Standard 8-01 or a TSMR will be required.

Loren Makus