Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: DP21-0298
Parcel: 111073140

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP21-0298
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/14/2022 SBEASLE1 START PLANS SUBMITTED Completed
03/09/2022 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change Comment not addressed. Only the data for the downstream manhole (8960-05A) is shown on the utility plan. [Initial comment: Provide the rim elevation of the next upstream sanitary manhole (8960-06A) is the next upstream manhole). Determine the need for a backwater valve per Section 714.1, IPC 2018, as amended by the City of Tucson.]
03/11/2022 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Self-Storage Development – 2538 N Country Club Rd
Development Package (2nd Review)
DP21-0298

TRANSMITTAL DATE: March 11, 2022

DUE DATE: March 14, 2022

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is November 02, 2022.

CONTENT REQUIREMENTS

1. Previous comment 1 - This comment was not fully addressed. The required information was not provided on sheet 18. COMMENT: 2-06.4.2.D - The page number and the total number of pages in the package (i.e., sheet xx of xx) shall be provided on all sheets.

2. Previous comment 2 - This comment was not fully addressed. The required information was not provided on sheet 18. COMMENT: 2-06.4.3 – Provide the development package case number, DP21-0298, adjacent to the title block on all sheets.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

3. Previous comment 6 - This comment was not fully addressed. Provide the required Use Specific Standards as stated below. COMMENT: 2-06.4.7.A.4 – As “SELF” storage is not a use recognized in the UDC revise General Note to state “PROPOSED USE PERSONAL STORAGE, SUBJECT TO USE SPECIFIC STANDARDS 4.9.10.C.3 & .6”

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

4. Previous comment 10 - This comment was not addressed. COMMENT: 2-06.4.9.E – As this site is made up of two (2) parcels a lot combination is required. Provide a copy of the approved Pima County Assessor’s Combo Request form with your next submittal.

5. Previous comment 11 - This comment was not fully addressed. Based on the ROW dimensions provided Country Club is not at full width, show the required future SVT’s based on the future ROW, required per comment 19l, on the plan. COMMENT: 2-06.4.9.H.2 - Show future and existing sight visibility triangles. On a designated MS&R street, the sight visibility triangles are based on the MS&R cross-section.

6. Previous comment 18 - This comment was not fully addressed. UDC Articles 7.4.9.B.1.e & 7.4.9.B.2.g were not addressed. Also the required 2’ x 6” space required per UDC Article 7.4.9.B.2.f is from the edge of rack not center, see UDC Figure 7.4.9-C. COMMENT: 2-06.4.9.H.5.d – As short-term bicycle parking is required for this use, see UDC Table 7.4.8-1: Minimum Required Bicycle Parking Spaces, provide a bicycle parking space calculation that shows the number required and provided. Also, clearly show the location on the plan and provided a detail that clearly demonstrates how the requirements of UDC Articles 7.4.9.B.1, B.2 & .C are met.

7. Previous comment 19 - This comment was not addressed. COMMENT: 2-06.4.9.J – Based on Paving Plan I-86-009 it does not appear that Country Club Rd is at full with based on the Cot MS&R plan. Show the future right-of-way (ROW) line, future curb and sidewalk on the plan. All new development must be designed to meet the future ROW.

8. Previous comment 21 - Zoning was not able to find the dimensioned sidewalks. COMMENT: 2-06.4.9.R – Provide a width dimension for the sidewalk along the west side of proposed building “B-B”.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov.

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
03/22/2022 JPEELDA1 FIRE REVIEW Approved Building is already existing non-conforming and fire sprinklers will be installed. Unable to meet current code with existing conditions on the property.
04/06/2022 AWARNER1 LANDSCAPE REVIEW Reqs Change CDRC TRANSMITTAL
TO: Planning and Development Services Department, Plans Coordination
FROM: Anne Warner, RLA
PDSD Landscape/Native Plant Preservation Section

PROJECT: Tucson Verdad Storage
ACTIVITY NO: DP21-0298, 2nd submittal
Address: 2538 N Country Club
Zoning: C-2
Existing Use: School
Proposed Use: Personal storage

TRANSMITTAL DATE: April 6, 2022
DUE DATE: March 14, 2022
COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Landscape Review Section comments were addressed.
This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting.
1. The Unified Development Code (UDC) requires all new development or an expansion of less than 50 % of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10.

2. The Landscape Calculations conflict with the Parking Requirement calculations, please revise.

3. This comment was not adequately addressed - Please add/call out soil moisture gauge/tensiometers and rain shut-off device on irrigation plans and details. UDC Tech Standards 4.01-2.A.

4. Please indicate the installation of a private submeter if a separate irrigation meter is not being provided. UDC Technical Standards 4-01.6.1.A.1.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package

YOUR NEXT STEPS: Submit documents to the Filedrop
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
Select "Existing Application"
1) Comment Response Letter (your response to
the reviewer's Requires changes comments)
2) Plan Set (or individual sheets)
3) Any other items requested by review staff

If you have any questions, please contact me at anne.warner@tucsonaz.gov
04/21/2022 SBLOOD1 ENGINEERING REVIEW Approved
04/27/2022 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Email from: COTDSDPermits
To: Russell Grimes
Wed 4/27/2022 5:11 PM

REVIEW NOTICE
Returned for Corrections: DP21-0298

DESCRIPTION: Site/Grading/Swppp - Self Storage redevelopment. 2538 N COUNTRY CLUB RD

FEE BALANCE: $ 165.00
(two additional hours review time by Fire Dept, at $82.50 per hour)

ONLINE PAYMENTS
** If amount doesn't match "Fee Balance", check back in a few hours **
https://www.tucsonaz.gov/pdsd/fees
1- Click on: Pay Planning & Permit Fees
2- Enter Permit Nbr, example: dp20-0000
(not case-sensitive but a hyphen-dash- is needed)
3- Business/Individual Name: Leave this field blank
4- "Continue"
5- In the Pay column - check the boxes
6- "Continue"

YOUR NEXT STEPS
1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

2. Title your THIRD submittal documents accordingly, example: 3_Comment Response Letter

3. UPLOAD A RESUBMITTAL to Filedrop:
- Comment Response Letter (your response to REQUIRES CHANGE comments)
- Plan Set (all pages, full set, even if no changes were made)
- Any other documents requested by review staff

- FILEDROP:
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- "Existing Application"
- "Permit Number" field: enter the number (and any notes for our staff)
- Select "PLANS" for all documents

Thank you.
Sharon Beasley, Certified Permit Specialist

City of Tucson, Planning and Development Services
Email: COTDSDpermits@TucsonAz.gov
04/27/2022 LSHAMIS1 PIMA COUNTY - ADDRESSING PIMA COUNTY - ADDRESSING Approved Email from: <Nicholas.Jordan@pima.gov>
Sent: Wednesday, April 27, 2022 9:28 AM
To: CDRC <CDRC@tucsonaz.gov>
Subject: DP21-0298, Self-Storage Redevelopment

Pima County Addressing conditionally approves DP21-0298, Self-Storage Redevelopment pending the application and approval of a lot consolidation by the Pima County Assessor’s Office.

Nicholas Jordan
Site Review Project Manager - Addressing Official

Pima County Development Services Department
201 N Stone AV – 1st Floor
Tucson, AZ 85701
(520) 724-9623