Permit Number: DP21-0297
Parcel: 122010100

Address:
4656 E GRANT RD

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP21-0297
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/24/2022 SBEASLE1 START PLANS SUBMITTED Completed
03/15/2022 SBEASLE1 UTILITIES TUCSON ELECTRIC POWER Approved See the Documents section of PRO for the following: TEP Facilities Map 03.11.22, TEP redline page 03.11.22, and TEP letter of approval, 03.11.22
03/17/2022 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Brake Masters – Grant & Swan
Development Package (2nd Review)
DP21-0297

TRANSMITTAL DATE: March 17, 2022

DUE DATE: March 22, 2022

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is October 31, 2022.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

1. Zoning acknowledges that a PDMR/TSMR has been submitted. If approved provide the case number adjacent to the title block on all sheets and provide a general note stating the case number, date of approval, what was modified and if applicable any conditions of approval. COMMENT: 2-06.4.9.H.5 – Demonstrate that the access lane along the west side of the building meets the minimum 20’ along with a 4” pedestrian refuge.

2. This comment was not addressed. If a Board of Adjustment is approved provide the case number adjacent to the title block on all sheets and provide a general note stating the case number, date of approval, what was modified and if applicable any conditions of approval. COMMENT: 2-06.4.9.H.5 – Per UDC Article 7.4.6.K access from an alley is not allowed. A Board of Adjustment for Variance is required.

3. The PDMR will need to be approved for the 19’ wide access lane. COMMENT: 2-06.4.9.H.5 – Provide an access lane width dimension from the curb that bumps out around the power pole called out under Keynote 6, to the building.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov.

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
03/23/2022 JPEELDA1 FIRE REVIEW Reqs Change Building is 4,846 and if we assume it is a type VB construction it would require 2,000 GPM. That would require 2 hydrants with 1,000 GPM for 2 hours each to be located within 400' of the building without crossing Grant or the building shall have fire sprinklers installed.

Questions:
Jennifer Peel-Davis
Jennifer.Peel-Davis@Tucsonaz.gov
520-837-7033
Fire Plans Examiner
04/15/2022 SBLOOD1 ENGINEERING REVIEW Reqs Change 1. Provide complete discussion, calculations and exhibits to establish accomplishment of first flush requirements. The applicability section (Section 2.1 on page 8) of the Design Standards for Stormwater Detention for Pima County outlines the requirements. For this project the first clause governs: "When new development is proposed on vacant land, all proposed impervious and disturbed areas shall be used to determine the required first-flush runoff volume." Per C9-21-17 Preliminary Zoning Condition 18 - The drainage and water harvesting plan for the site will be designed as from the undeveloped state (vacant land).
2. For calculations supporting first-flush retention provide a table accounting for the entire project area and applicable volumes. See the examples on pages 12 and 13 of the manual.
3. Provide an exhibit showing all developed watersheds and associated retention areas. Impervious, disturbed, and non-contributing areas must be shown with measurements.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
04/15/2022 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Email from: COTDSDPermits
to: lisa bowers
Fri 4/15/2022 1:58 PM

REVIEW NOTICE
Returned for Corrections: DP21-0297

DESCRIPTION: Site/Grading - Brakemasters.

FEE BALANCE: $ 165.00
ONLINE PAYMENTS
** If amount doesn't match "Fee Balance", check back in a few hours **
https://www.tucsonaz.gov/pdsd/fees
1- Click on: Pay Planning & Permit Fees
2- Enter Permit Nbr, example: dp20-0000
(not case-sensitive but a hyphen-dash- is needed)
3- Business/Individual Name: Leave this field blank
4- "Continue"
5- In the Pay column - check the boxes
6- "Continue"

YOUR NEXT STEPS
1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab to see different sections
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

2. Title your THIRD submittal documents accordingly, example: 3_Comment Response Letter

3. UPLOAD A RESUBMITTAL to Filedrop:
1) Comment Response Letter (your response to REQUIRES CHANGE comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

- FILEDROP:
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- "Existing Application"
- "Permit Number" field: enter the number (and any notes for our staff)
- Select "PLANS" for all documents


Sharon Beasley, Certified Permit Specialist

City of Tucson, Planning and Development Services
Email: COTDSDpermits@TucsonAz.gov