Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP21-0292
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
02/10/2022 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
03/10/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: Self Storage – 5642 S Alvernon Way Development Package (2nd Review) DP21-0292 TRANSMITTAL DATE: March 9, 2022 DUE DATE: March 10, 2022 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is November 09, 2022. CONTENT REQUIREMENTS 1. This comment was not fully addressed. Sheets 50-52 do not have the page number and the total number of pages. COMMENT: 2-06.4.2.D – Provide the page number and the total number of pages in the package (i.e., sheet xx of xx) on all sheets. 2. This comment was not fully addressed. Sheets 50-52 do not have the DP case number. COMMENT: 2-06.4.3 – Provide the development package case number, DP21-0292, adjacent to the title block on all sheets. 3. This comment was not fully addressed. The section corners were not labeled.COMMENT: 2-06.4.4.C – The section, township, and range & section corners will be labeled on the location map. 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. 2-06.4.7.A - Zoning and Land Use Notes 4. This comment was not addressed. “CITY OF TUCSON ZONING NOTE” 2, was note 3, does not list the required Use Specific Standards. Review UDC TABLE 4.8-4: PERMITTED USES - COMMERCIAL AND MIXED-USE ZONES, C-2 Zone, Storage Use Group With Land Use Class/Type: Personal Storage, C-2 and provide the correct Use Specific Standards. COMMENT: 2-06.4.7.A.4 – The Use Specific Standards listed under “CITY OF TUCSON ZONING NOTE” 3 are not correct. Review UDC TABLE 4.8-4: PERMITTED USES - COMMERCIAL AND MIXED-USE ZONES, C-2 Zone, Storage Use Group With Land Use Class/Type: Personal Storage, C-2 and provide the correct Use Specific Standards. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 5. This comment was not fully addressed. Zoning not able to find the required detail. COMMENT: 2-06.4.9.H.5.d – Provide a short-term bicycle parking space calculation on the plan, clearly show where the required short-term bicycle parking is located and provide a detail that demonstrates how the requirements of UDC Article 7.4.9 are met. 6. TSMR DS22-03 has been approved. Provide the TSMR case number adjacent to the title block on all sheets. Also provide a general note stating the case number, date of approval, what was modified and if applicable any conditions of approval. COMMENT: 2-06.4.9.R – Per TSM Section 7-01.4.1.B a sidewalk is required adjacent and parallel to any access lane or PAAL on the side where buildings are located. Demonstrate that this requirement is met for all areas of the site. 7. Per 2018 IBC Chapter 11 Section 1104.2 within a site at least one accessible route shall connect accessible buildings, accessible facilities, accessible elements and accessible spaces that are on the same site. Provide the accessible route to all buildings on site or secure a Petition of Appeal to the Building Office. Application and requirements can be found at: https://www.tucsonaz.gov/pdsd/building-code-modification-appeals. COMMENT: 2-06.4.9.R- Per TSM Sections 7-01.3.3.B the areas within the development which must be connected include, but are not limited to, all buildings, all bicycle and vehicle parking areas, all recreation areas, all dumpster areas, and all other common use areas. Demonstrate that this requirement is met for all areas of the site. As this development was lacking substantial calculations and information additional comments maybe forth coming. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov. To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
03/18/2022 | DSTIFFE1 | COT NON-DSD | TRAFFIC | Completed | DP21-0292 Comments: 1. New P.A.G. standard 207 Curb Access Ramp needed at NW corner of Felix Blvd and the "Emergency Access Only" ingress/ egress entry. 2. New 5 Ft. wide- P.A.G. standard 200 Concrete Sidewalk to extend along property frontage of Felix Blvd to end of property. 3. Sheet C12- Revise keynotes: (11) (12) to reference the current P.A.G. standards, rather than Pima PCDOT. 4. Sheet C11- Revise keynotes: (11) (12) to reference the current P.A.G. standards, rather than Pima PCDOT. David Stiffey DTM Project Coordinator David.Stiffey@tucsonaz.gov |
03/22/2022 | JPEELDA1 | COT NON-DSD | FIRE | Approved | |
04/14/2022 | AWARNER1 | LANDSCAPE | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Planning and Development Services Department, Plans Coordination FROM: Anne Warner, RLA PDSD Landscape/Native Plant Preservation Section PROJECT: Self-Storage Tucson ACTIVITY NO: DP21-0292 Address: 4652 S Alvernon Wy Zoning: C-2 Existing Use: vacant land Proposed Use: self-storage TRANSMITTAL DATE: April 14, 2022 DUE DATE: March 10, 2022 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Landscape Review Section comments were addressed. This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting. 1. I-2 is not the correct zoning, please correct. 2. The irrigation legend is missing on all pages. Please add, and make sure this comment is addressed - add/call out soil moisture gauge/tensiometers and rain shut-off device on irrigation plans and details. UDC Tech Standards 4.01-2.A. 3. The civil plans indicate a water meter, but do not specify that it is exclusively for irrigation. Please indicate the installation of a private submeter if a separate irrigation meter is not being provided. UDC Technical Standards 4-01.6.1.A.1. 4. As noted previously, mitigation trees are in addition to landscape border and parking area trees. There should be additional trees installed, 68 mitigation trees/shrubs, 59 for borders, 7 for parking = 134. 5. Per Admin. Manual 2-10-4.2.D, provide page/detail reference to civil drawings/details that show bike racks, walkways, and screening/retaining walls on landscape plans. See civil drawing is not sufficient. 6. This comment was not adequately addressed - Identify the point of drainage off roof areas, amount of flow, and disposition of flow. 7. This comment was not adequately addressed - Identify curb inlets/splash pads to landscape areas on water harvesting or landscape plans. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package YOUR NEXT STEPS: Submit documents to the Filedrop https://docs.tucsonaz.gov/Forms/tucsonpermitapp Select "Existing Application" 1) Comment Response Letter (your response to the reviewer's Requires changes comments) 2) Plan Set (or individual sheets) 3) Any other items requested by review staff If you have any questions, please contact me at anne.warner@tucsonaz.gov |
04/21/2022 | SBLOOD1 | ENGINEERING | REVIEW | Reqs Change | 1. Fix overlapping text on page 2. 2. 7. On the drainage report include an exhibit to go along with the first flush calculations that help illustrate the numbers used in the spreadsheet calculations. The exhibit should include such elements as: undisturbed areas delineated and sq footage, disturbed areas delineated and sq footage, impervious surfaces delineated and sq footage, non-contributing basins with landscape delineated and sq footage, stormwater harvesting basins including first flush delineated and sq footage, stormwater harvesting basin #s, flow direction, and water shed #s. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
04/27/2022 | SBEASLE1 | PIMA COUNTY - ADDRESSING | PIMA COUNTY - ADDRESSING | Needs Review | |
04/27/2022 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | Email from: COTDSDPermits To: Stephen Litsas Wed 4/27/2022 2:53 PM REVIEW NOTICE Returned for Corrections: DP21-0292 DESCRIPTION: Site/Grading: Self Storage - Tucson. Storage units, RV storage stalls, office. 5642 S ALVERNON WY FEE BALANCE: $ 165.00 (additional two hours for Fire Dept review, $82.50 per hour) ONLINE PAYMENTS ** If amount doesn't match "Fee Balance", check back in a few hours ** https://www.tucsonaz.gov/pdsd/fees 1- Click on: Pay Planning & Permit Fees 2- Enter Permit Nbr, example: dp20-0000 (not case-sensitive but a hyphen-dash- is needed) 3- Business/Individual Name: Leave this field blank 4- "Continue" 5- In the Pay column - check the boxes 6- "Continue" YOUR NEXT STEPS 1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab - Reviews section - click on REVIEW DETAILS - Documents section - click on VIEW 2. Title your THIRD submittal documents accordingly, example: 3_Comment Response Letter 3. UPLOAD A RESUBMITTAL to Filedrop: 1) Comment Response Letter (your response to REQUIRES CHANGE comments) 2) Plan Set (all pages, full set, even if no changes were made) 3) Any other documents requested by review staff - FILEDROP: https://docs.tucsonaz.gov/Forms/tucsonpermitapp - "Existing Application" - "Permit Number" field: enter the number (and any notes for our staff) - Select "PLANS" for all documents Thank you. Sharon Beasley, Certified Permit Specialist City of Tucson, Planning and Development Services Email: COTDSDpermits@TucsonAz.gov |