| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/04/2022 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 02/07/2022 | JOHN BEALL | COT NON-DSD | COMMUNITY PLANNING | Completed | |
| 02/23/2022 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 03/08/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: Casas Del Cerrito Lots 1-49 FLD Subdivision Development Package (2nd Review) DP21-0284 TRANSMITTAL DATE: March 8, 2022 DUE DATE: March 3, 2022 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is October 21, 2022. 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. 2-06.4.7.A - Zoning and Land Use Notes 1. COMMENT: 2-06.4.7.A.3 – Clarify why rezoning conditions 12 – 19 are repeated on sheet 2. 2-06.5.0 FLEXIBLE LOT DEVELOPMENT (FLD - ADDITIONAL REQUIREMENTS) 2-06.5.3 Additional Information The following are required in addition to the requirements of the tentative plat or site plan, whichever is applicable: 2. The provided functional open space calculation provides the required but does not provide the proposed. Provide the proposed open spaces on the plan. COMMENT: 2-06.5.3.C – Provide a functional open space calculation on sheet 1 that meets the requirements of UDC Article 8.7.3.D. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov. To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 03/10/2022 | JPEELDA1 | COT NON-DSD | FIRE | Approved | |
| 03/18/2022 | DSTIFFE1 | COT NON-DSD | TRAFFIC | Approved | No Comments |
| 04/05/2022 | SBLOOD1 | ENGINEERING | REVIEW | Approved | |
| 04/05/2022 | AWARNER1 | LANDSCAPE | REVIEW | Approved | |
| 04/14/2022 | SBEASLE1 | UTILITIES | TUCSON ELECTRIC POWER | Approved | Email from: <TEPDEVREV@tep.com> Sent: Wednesday, April 13, 2022 To: CDRC <CDRC@tucsonaz.gov> Subject: Casas Del Cerrito, DP21-0284, 2nd submittal review This plat is approved. As identified on the Preliminary Drawing, easements for Tucson Electric Power Co. (TEP) facilities must be shown on the final plat and provided to TEP for review before submittal for approval. The customer is responsible for compliance with City Ordinances. Please note Jurisdictional permit for any work on public road right of way. Should you have any easement questions, don't hesitate to get in touch with tepdevrev@tep.com. |
| 05/05/2022 | NMARTEL1 | DESIGN PROFESSIONAL | REVIEW | Passed | Staff acknowledge the deferred submittal for the AVP and PMP to be done before issuance of building permits |
| 05/10/2022 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | Email from: COTDSDPermits To: C McMillan cc: Natalee Wareham Tue 5/10/2022 5:32 PM REVIEW NOTICE Returned for Corrections: DP21-0284 DESCRIPTION: Site/Grading/FLD/Floodplain - Casas Del Cerrito, Lots 1 thru 49, and Common Areas "A" (open space, drainage), and "B" (open space, public streets). Fee Balance: Credit -$2497.87 YOUR NEXT STEPS 1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab - Reviews section - click on REVIEW DETAILS - Documents section - click on VIEW 2. Title your THIRD submittal documents accordingly, example: 3_Comment Response Letter 3. UPLOAD A RESUBMITTAL to Filedrop: - Comment Response Letter (your response to REQUIRES CHANGE comments) - Plan Set (all pages, full set, even if no changes were made) - Any other documents requested by review staff - FILEDROP: https://docs.tucsonaz.gov/Forms/tucsonpermitapp - "Existing Application" - "Permit Number" field: enter the number (and any notes for our staff) - Select "PLANS" for all documents Sharon Beasley, Certified Permit Specialist City of Tucson, Planning and Development Services Email: COTDSDpermits@TucsonAz.gov |
| 05/10/2022 | JENNIFER STEPHENS | PIMA COUNTY | ADDRESSING | Approved | EMail from: Nicholas Jordan <Nicholas.Jordan@pima.gov> To: CDRC Tue 5/10/2022 9:09 AM Pima County Addressing approves DP21-0284, Casas Del Cerrito. Thank you Nicholas Jordan Site Review Project Manager - Addressing Official |