Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: DP21-0281
Parcel: 140360170

Address:
4975 E BENSON HY

Review Status: Completed

Review Details: TENTATIVE PLAT REVIEW

Permit Number - DP21-0281
Review Name: TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/23/2022 SBEASLE1 START PLANS SUBMITTED Completed
03/17/2022 STEVE SHIELDS ZONING REVIEW Approved
03/23/2022 SBEASLE1 OTHER AGENCIES TUCSON AIRPORT AUTHORITY Approved See the "Documents" section of PRO for document titled: "Tucson Airport, letter of approval, 03.21.22"
03/24/2022 DSTIFFE1 COT NON-DSD TRAFFIC Reqs Change DP21-0281
Traffic Eng Review
Comments:
1. Comment number one remains. Please show 6 Ft wide sidewalk and necessary curb access ramps along Valencia Rd on the plans.
2. Also provide a "Key Note" which will state that the 6' sidewalk will be constructed per P.A.G. standard 200 and a "Key Note" which will state that the curb access ramps will be constructed per P.A.G. standard 207.
3. Show 5 Ft wide sidewalk along East Valencia Crossing Drive, and a "Key Note" mentioning this and that the sidewalk will be constructed per P.A.G. standard 200.
4. Previous comment number three remains. "Western most private access easement bisects an existing storm drain inlet (CB.) Show on the plans how this will be addressed.
5. New curb returns along Valencia Rd need to have a 25' radius. Show this on the plans.
6. Any new curb returns on East Valencia Crossing Drive need to have an 18' radius. Show this on the plans.
7. New concrete curb needs to be shown on the plans and a Key Note stating it will be installed per P.A.G. standard 209.
8. All of the Sight Visibility Triangles are drawn incorrectly on the plan. The tangent line of the triangle needs to be tangential and in line with the curb line of the street of which the SVT is noting. Please correct this.

David Stiffey
DTM Project Coordinator
David.Stiffey@tucsonaz.gov
03/30/2022 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Reqs Change See the document in the "Documents" section of PRO titled: "ADOT, second submittal review comments, 03.21.22"
04/20/2022 JOHN BEALL COT NON-DSD COMMUNITY PLANNING Completed
05/19/2022 SBLOOD1 ENGINEERING REVIEW Approved 1. The plans are clear in scope and provide enough detail and approval to use a scale less than 1"=50' is granted for this plan set.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
06/14/2022 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Email from: COTDSDPermits
To: Steven Vasquez
Tue 6/14/2022 2:27 PM

REVIEW NOTICE
Returned for Corrections: DP21-0281

Project Description: Tentative Block Plat/Floodplain - Valencia Crossing Commercial, Lots 1 thru 7.
4975 E BENSON HY

Fee Balance: $0 (zero) Thank you for the payment.

YOUR NEXT STEPS
1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

2. Title your THIRD submittal documents accordingly, example: 3_Comment Response Letter

3. UPLOAD A RESUBMITTAL to Filedrop:
- Comment Response Letter (your response to REQUIRES CHANGE comments)
- Plan Set (all pages, full set, even if no changes were made)
- Any other documents requested by review staff

- FILEDROP
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- "Existing Application"
- "Permit Number" field: enter the number (and any notes for our staff)
- Select "PLANS" for all documents

Thank you.
Sharon Beasley, Certified Building Technician

City of Tucson, Planning & Development Services Dept.
Email: COTDSDpermits@TucsonAz.gov
(for development packages, land splits, Thursday Presubmittal meetings)

Email: PDSDinquiries@TucsonAz.gov
(for building permits and all other subjects)
06/23/2022 SBEASLE1 PIMA COUNTY - ADDRESSING PIMA COUNTY - ADDRESSING Approved Email from: Nicholas Jordan <Nicholas.Jordan@pima.gov>
To: CDRC
Thu 6/23/2022 4:02 PM

Pima County Addressing approves DP21-0281, Tentative Plat, Valencia Crossing.
Thank you

Nicholas Jordan
Site Review Project Manager - Addressing Official

Pima County Development Services Department
201 N Stone AV – 1st Floor
Tucson, AZ 85701
(520) 724-9623