Permit Number: DP21-0269
Parcel: 12213048B

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP21-0269
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/28/2021 SBEASLE1 START PLANS SUBMITTED Completed
10/28/2021 SBEASLE1 ENGINEERING REVIEW Passed Review was passed by Loren Makus during the OK to Submit.
11/02/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Proposed Smoke Shop – Site Fencing – 1144 N Alvernon Way
Development Package (1st Review)
DP21-0269

TRANSMITTAL DATE: November 2, 2021

DUE DATE: November 2, 2021

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is October 05, 2022.

2-06.2.0 APPLICATION SUBMITTAL REQUIREMENTS

1. COMMENT: 2-06.2.4 – As a development package is designed to all for concurrent review of any site related reviews, not building code reviews remove all references to non-applicable building codes.

CONTENT REQUIREMENTS

2. COMMENT: 2-06.4.1 – Provide the email and phone number for the Owner listed on the plan.

3. COMMENT: 2-06.4.3 – Provide the development package case number, DP21-0269, adjacent to the title block on all sheets.

4. COMMENT: 2-06.4.4.C – The section listed under the location map is not correct.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

5. COMMENT: 2-06.4.7.A.4 - Identify the existing and proposed use of the property as classified per the UDC. List all UDC sections applicable to the proposed uses. Smoke shop is not a use recognized in the UDC and should be listed as General Merchandise Sales, excluding Large Retail Establishment, subject to Use Specific Standards 4.9.9.B.3 and 4.9.13.O, see UDC TABLE 4.8-4: PERMITTED USES - COMMERCIAL AND MIXED-USE ZONES.
6. COMMENT: 2-06.4.7.A.6.a – Provide a general note stating “THIS PROJECT IS DESIGNED TO MEET THE OVERLAY ZONE(S) CRITERIA, UDC ARTICLE 5.4 MAJOR STREETS AND ROUTES SETBACK ZONE (MS&R).”

2-06.4.7.A.8 - For development package documents provide:

2-06.4.8 - Existing Site Conditions
The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided.

7. COMMENT: 2-06.4.8.A - - Provide site boundary perimeter information, including bearing in degrees, minutes, and seconds.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

8. COMMENT: 2-06.4.9.H.5.a – Per UDC Article 7.4.6.D.b The minimum width of a vehicle parking space when adjacent to barrier is 10’-0” wide. That said, the vehicle parking space directly west of the proposed fence is required to be 10’-0” wide. Provide a dimension from the east edge of the vehicle parking space to the proposed fence. This dimension shall be 1’-6” minimum.

9. COMMENT: 2-06.4.9.H.5.a – Per 2018 IBC Chapter 11, Section 1106.5 for every six or fraction of six accessible parking spaces, at least one shall be van accessible. That said, the provided accessible parking space shall meet the requirements of ICC A117.1-2009 Section 502.2 for a van accessible space

10. COMMENT: 2-06.4.9.H.5.a – As the three (3) parcels and two (2) buildings operate as a single site the vehicle parking space calculation shall include both buildings.

11. COMMENT: 2-06.4.9.H.5.a – The proposed accessible parking space sign appears to encroach into the 2’-6” vehicle overhang. Clearly demonstrate that the overhang is clear of any obstruction.

12. COMMENT: 2-06.4.9.H.5.a – The mounting height for the accessible parking space sign should be 7’-0” to the bottom of the accessible sign.

13. COMMENT: 2-06.4.9.R – Clearly demonstrate how accessibility access is provided to the existing building. It is not clear if the sidewalk is flush or if some type of ramp is proposed.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov.

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
11/16/2021 JPEELDA1 FIRE REVIEW Approved
11/19/2021 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Email from: COTDSDPermits
To: 420 smoke shop
Fri 11/19/2021 1:16 PM

Returned for Corrections: DP21-0269

DESCRIPTION: Site - 420 Smoke Shop. Approval requested for old fence that has been replaced with new fence. 1144 N ALVERNON WY

FEE BALANCE: $ 264.00
Please pay at a minimum, the REVIEW category fees.
A payment is required before your next submittal.

ONLINE PAYMENT
If amount doesn't match "Fees Due", check back in a few hours
https://www.tucsonaz.gov/pdsd/fees
1- Click on: Pay Planning & Permit Fees
2- Enter Permit Nbr, example: dp20-0000
(not case-sensitive but a hyphen-dash- is needed)
3- Business/Individual Name: Leave this field blank
4- "Continue"
5- In the Pay column - check the boxes
6- "Continue"

SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab to see different sections
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

INCLUDE IN RESUBMITTAL
1) Comment Response Letter (your response to REQUIRES CHANGE comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

Please title your SECOND submittal documents according to this example: 2_Comment Response Letter

FILEDROP for your Resubmittal
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- Select "Existing Application"
- In the "Permit Number" field, enter the number and, if applicable, any notes for our staff


Thank you.
Sharon Beasley, Building Permit Specialist

City of Tucson, Planning and Development Services
Email: COTDSDpermits@TucsonAz.gov
(disregard the email response that will be sent automatically)