Permit Review Detail
Review Status: Completed
Review Details: TENTATIVE PLAT REVIEW
Permit Number - DP21-0259
Review Name: TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/19/2022 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 01/27/2022 | SBLOOD1 | ENGINEERING | REVIEW | Approved | |
| 02/03/2022 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | Verify the need for backwater valves for lots 86, 89, and 90 in parcel 7 and lot 38 in parcel 8. Each of these lots appear to have a FFE more than 12" above the rim elevation of the next upstream manhole. [Initial comment: Revise the site drawing to indicate for which lots backwater valves will be required because the rim elevation of the next upstream sanitary manhole is less than 12" below the proposed first floor elevations. Reference: Section 714.1, IPC 2018, as amended by the City of Tucson.] |
| 02/15/2022 | SBEASLE1 | PIMA COUNTY | ADDRESSING | Approved | Email from: <Addressing@pima.gov> To: CDRC cc: Andie Hemmah Mon 2/14/2022 4:33 PM Pima County Addressing approves La Estancia, Tentative Plat, 2nd Submittal Review: DP21-0259. Thank you Nicholas Jordan, Addressing Specialist Pima County Development Services Department 201 N Stone AV – 1st Floor Tucson, AZ 85701, (520) 724-9623 |
| 02/16/2022 | SBEASLE1 | COT NON-DSD | TRAFFIC | Reqs Change | Email from: David.Stiffey@TucsonAz.gov To: CDRC Tue 2/15/2022 11:19 AM DP21-0259 Sheets 7 and 8: Please add Sight Visibility Triangles where project entrances intersect with Camino Boleadoras. Include lengths. |
| 02/28/2022 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 03/23/2022 | AWARNER1 | LANDSCAPE | REVIEW | Needs Review | |
| 03/23/2022 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | Email from: COTDSDPermits To: Andie Hemmah Wed 3/23/2022 5:13 PM REVIEW NOTICE Returned for Corrections: DP21-0259 DESCRIPTION: Tentative Plat - La Estancia, Parcels 6 thru 8. 6670 E CAMINO BOLEADORAS Fee Balance: $0 (zero) Thank you for the payment. YOUR NEXT STEPS 1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab to see different sections - Reviews section - click on REVIEW DETAILS - Documents section - click on VIEW 2. UPLOAD A RESUBMITTAL and include: 1) Comment Response Letter (your response to REQUIRES CHANGE comments) 2) Plan Set (all pages, full set, even if no changes were made) 3) Any other documents requested by review staff Please title your THIRD submittal documents accordingly, example: 3_Comment Response Letter FILEDROP: https://docs.tucsonaz.gov/Forms/tucsonpermitapp - "Existing Application" - In the "Permit Number" field, enter the number and, if applicable, any notes for our staff - Select "PLANS" for all documents for quicker downloading on our end Thank you. Sharon Beasley, Building Permit Specialist City of Tucson, Planning and Development Services Email: COTDSDpermits@TucsonAz.gov |
| 03/23/2022 | JPEELDA1 | COT NON-DSD | FIRE | Reqs Change | Fire department access road dead ends. IFC 2018, Appendix D, D103.4 Dead ends. Dead-end fire apparatus access roads in excess of 150 ft shall be provided with width and turn around provisions in accordance with Table D103.4. Cul-de-Sac shall have a 96 foot diameter from curb to curb. COT uses the UDC and the IFC shall take precedence on the dead-end cul-de-sac. Questions: Jennifer Peel-Davis Jennifer.Peel-Davis@Tucsonaz.gov 520-837-7033 Fire Plans Examiner |