Permit Review Detail
Review Status: Completed
Review Details: TENTATIVE PLAT REVIEW
Permit Number - DP21-0258
Review Name: TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/13/2022 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 05/19/2022 | SBLOOD1 | ENGINEERING | REVIEW | Reqs Change | Tentative Plat Comments: Sheet 1 1. Please add the following items to legend: Easement, UE line, UGC line, existing edge of pavement, utility poles, utility boxes, hydrants, fence, water, contours 2. Please specify whether items are existing or proposed in Legend. (Hog wire fence, OHE, etc) 3. Please reference a benchmark and datum to determine basis of elevation per AM 2-06.40 4. Please identify the location of visitor parking on plan. Sheet 2 5. Please add fence linetype appearing on the back of lots property line to legend and plot black. 6. Please identify any easements/setbacks within the keynotes. 7. Regarding Keynote 11, please provide proposed relocated fence location in plan. 8. Please review required setbacks and where the dimension label shown in plan is measuring from versus what is required. 9. Please distinguish between Existing and Future R/W lines in the keynotes. 10. Please provide fence and HW linework callouts to clarify their locations since they are masked by the property line. 11. This plan set does not meet the content requirements listed in AM 2-06 and therefore cannot be adequately reviewed. Please review these content requirements and resubmit. These requirements include, but are not limited to: providing pad grades and typical grading scheme detail, adjacent grading to characterize the existing offsite flow conditions, elevations to connect to along Jeanette, access to lots across proposed vertical curbs, location of access ramps, proposed utility connections (sewer, water,etc.) and adjacent roadway dimensions and information. Drainage Statement Comments: 1. Page 1 of 5 -Per COT Drainage Manual Section 2.1.1, a drainage report is required for all developments greater than 1 acre. Please resubmit a drainage report following the guidelines outlined in the COT Manual. Please provide coversheet with project name, case number, Township, section, range, name, address and phone number of owner (and of engineering firm), and submittal date. Please also move seal and signature to cover sheet. 2. Page 5 of 5 Developed Condition Hydrologic data sheet - imperviousness shows 60% even though this is an empty lot. Please revise impervious value. Developed is onsite and offsite, whereas existing is only onsite. Please also provide onsite calcs for existing conditions 3. General Comment - Per COT requirements, detention and first flush retention is required for all developments greater than 1 acre in size. Please refer to the Pima County Detention/Retention Manual and revise design to meet requirements. 4. General Comment - Please include a discussion of how off-site flows enter the proposed development and any impacts to each lot that will occur. 5. General Comments - Please revise exhibits and provide at a scale and level of detail consistent with requirements set in section 2.3.1.3 of the COT Drainage Manual. This project was reviewed by a contract reviewer. If you have questions about these comments, please contact Stephen Blood at Stephen.Blood@TucsonAz.gov or Loren Makus at Loren.Makus@TucsonAz.gov |
| 06/14/2022 | STEVE SHIELDS | ZONING | REVIEW | Approv-Cond | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: Tentative Plat at the NEC of Bilby & Jeanette Development Package (3rd Review) DP21-0258 TRANSMITTAL DATE: June 14, 2022 DUE DATE: June 10, 2022 The Zoning Review Section conditionally approves the development package for this project subject to addressing the following comments. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development package to verify that those changes do not affect any zoning requirements. 1. This comment was not correctly. Remove the reference to “SUBJECT TO SPECIAL USE STANDARD 4.9.7.b.6,.9 & .10” as it is not applicable, see TABLE 4.8-2: PERMITTED USES - URBAN RESIDENTIAL ZONES, MH-1 Zone. 2-06.4.7.A.4 - Identify the existing and proposed use of the property as classified per the UDC. List all UDC sections applicable to the proposed uses. If you have any questions about this transmittal, please contact Nicholas Ross at Nicholas.Ross@tucsonaz.gov. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 06/17/2022 | SBEASLE1 | OTHER AGENCIES | TUCSON AIRPORT AUTHORITY | Reqs Change | (This letter can be viewed as a PDF. See "documents" section of PRO for document titled "TAA review comments, 3rd submittal, 06.16.22") June 16, 2022 RE: DP21-0258 / Tentative Plat - The Tree Estates, Lots 1 thru 6, 3rd Submittal, Received May 13, 2022 Thank you for the opportunity to comment on DP21-0258 / Tentative Plat - The Tree Estates, Lots 1 thru 6; 3rd Submittal, a development package application of a 0.966 acre site located northeast of the intersection of East Bilby Road and South Jeanette Boulevard. The property is zoned Mobile Home Zone 1 (MH-1), with the proposed development containing six single family residential lots. This site is within the Tucson International Airport avigation easement requirements and public disclosure area, FAA traffic pattern airspace, and FAA Part 77 airspace. The Tucson Airport Authority conditionally approves the 3rd submittal of this project and requests to be included on the next submittal of this project to insure that the required forms have been submitted to the Tucson Airport Authority. Please do not hesitate to contact me if you have any questions or concerns regarding this comment letter. I can be reached by email at srobidoux@flytucson.com or by telephone at 520-573-4811. Respectfully, Scott Robidoux, C.M., Manager of Planning |
| 07/06/2022 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | Email from: COTDSDPermits To: Jeffrey Stanley cc: Jr. Valdez Wed 7/6/2022 1:34 PM REVIEW NOTICE Returned for Corrections: DP21-0258 Project Description: Tentative Plat - The Tree Estates, Lots 1 thru 6. 1131 E BILBY RD Fee Balance: $0 (zero) Thank you for the payment. YOUR NEXT STEPS 1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab - Reviews section - click on REVIEW DETAILS - Documents section - click on VIEW 2. Title your FOURTH submittal documents accordingly, example: 4_Comment Response Letter 3. UPLOAD A RESUBMITTAL to Filedrop: - Comment Response Letter (your response to REQUIRES CHANGE comments) - Plan Set (all pages, full set, even if no changes were made) - Any other documents requested by review staff FILEDROP https://docs.tucsonaz.gov/Forms/tucsonpermitapp - "Existing Application" - "Permit Number" field: enter the number (and any notes for our staff) - Select "PLANS" for all documents Thank you. Sharon Beasley, Certified Building Technician City of Tucson, Planning & Development Services Dept. Email: COTDSDpermits@TucsonAz.gov (for development packages, land splits, Thursday Presubmittal meetings) Email: PDSDinquiries@TucsonAz.gov (for building permits) |