Permit Number: DP21-0255
Parcel: 128100770

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP21-0255
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/14/2022 SBEASLE1 START PLANS SUBMITTED Completed
01/27/2022 SBLOOD1 ENGINEERING REVIEW Reqs Change 1. Show compliance with UDC article 7.6.6.C.2 and how this site plan is maximizing water harvesting. Looks like water is flowing to the new landscape areas but it isn't clear if all the landscape areas are depressed 6-9 inches in order to capture and harvest any of that water. Revise the grading plan with contours/spot grades to show the landscaping depressed.
2. Show on the grading plan the sidewalk cut outs for the trees along the parking to match the site plan and landscaping plan.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
02/02/2022 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change Sheet C1.0 appears to show the next upstream manhole with a rim elevation of 2558.49'which is less than 12" below the first floor elevation (2559.01'). Provide a note on the plans requiring the installation of a backwater valve when future plumbing activities take place. Reference: Section 714.1, IPC 2018, as amended by the City of Tucson.
02/14/2022 AWARNER1 ZONING REVIEW Reqs Change
02/14/2022 AWARNER1 LANDSCAPE REVIEW Reqs Change CDRC TRANSMITTAL
TO: Planning and Development Services Department, Plans Coordination
FROM: Anne Warner, RLA
PDSD Landscape/Native Plant Preservation Section

PROJECT: Williams Center Gym
ACTIVITY NO: DP21-255, 2nd submittal
Address: 5180 E Williams Circle
Zoning: PAD-1
Existing Use: Bank
Proposed Use: Gym

TRANSMITTAL DATE: February 14, 2022
DUE DATE: February 14, 2022
COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Landscape Review Section comments were addressed.
This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting.
1. UDC 2-10.4.1 Identification and Descriptive Data
A. All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.
• The grading and drainage plan do not match the landscape plan
• No landscape response letter was included with the submittal.

Ensure that Zoning and Engineering comments are addressed prior to landscape section approval.

2. A Commercial Rainwater Harvesting plan is required UDC Technical Standards Manual – Section 4-01.0.0. and Section 5-01.0.0 Landscaping and Screening. The grading plan

3. Adherence to the Low Impact Development Standards outlined in Section 5 of the PCRFCD Design Standards for Stormwater Detention and Retention is required and shall work in conjunction with the Commercial Rainwater Harvesting design.
https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Flood%20Control/Rules%20and%20Procedures/Stormwater%20Detention-Retention/dssdr-manual-board-version-201511.pdf

4. Grading, hydrology, and landscape plans must be integrated to make maximum use of site storm water runoff for supplemental on-site irrigation purposes. The landscape plan shall indicate use of all runoff, from individual catch basins around single trees to basins accepting flow from an entire vehicular use area or roof area. UDC 7.7.6.C.2. The landscape and grading plans must match.

5. Identify the point of drainage off roof areas, amount of flow, and disposition of flow.

6. Identify curb inlets to landscape areas.

7. Modify details to show depressed landscape areas.

8. Please indicate the installation of a private submeter if a separate irrigation meter is not being provided. UDC Technical Standards 4-01.6.1.A.1.

9. Please add/call out soil moisture gauge/tensiometers and rain shut-off device on irrigation plans and details. UDC 4.2.A.

10. Provide a detail to show tree planting with root barrier adjacent to walkways.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package

YOUR NEXT STEPS: Submit documents to the Filedrop
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
Select "Existing Application"
1) Comment Response Letter (your response to
the reviewer's Requires changes comments)
2) Plan Set (or individual sheets)
3) Any other items requested by review staff

If you have any questions, please contact me at anne.warner@tucsonaz.gov
02/16/2022 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Email from: COTDSDPermits
To: Andrew
Wed 2/16/2022 10:42 AM

REVIEW NOTICE
Returned for Corrections: DP21-0255

DESCRIPTION: Site: Williams Centre. Building addition for gym. 5180 E WILLIAMS CI

FEE BALANCE: $ 1,206.50
Please pay at a minimum, the REVIEW category fees.
A payment is required before your next submittal.

ONLINE PAYMENT
If amount doesn't match "Fees Due", check back in a few hours
https://www.tucsonaz.gov/pdsd/fees
1- Click on: Pay Planning & Permit Fees
2- Enter Permit Nbr, example: dp20-0000
(not case-sensitive but a hyphen-dash- is needed)
3- Business/Individual Name: Leave this field blank
4- "Continue"
5- In the Pay column - check the boxes
6- "Continue"

YOUR NEXT STEPS
1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab to see different sections
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

2. UPLOAD A RESUBMITTAL and include:
1) Comment Response Letter (your response to REQUIRES CHANGE comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

Please title your THIRD submittal documents according to this example: 3_Comment Response Letter

FILEDROP for your Resubmittal
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- Select "Existing Application"
- In the "Permit Number" field, enter the number and, if applicable, any notes for our staff
- Select "PLANS" for all documents for quicker downloading of your documents on our end

Thank you.