Permit Number: DP21-0254
Parcel: 117121290

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP21-0254
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/23/2021 SBEASLE1 ENGINEERING REVIEW Passed Passed during the OK to Submit.
09/23/2021 SBEASLE1 START PLANS SUBMITTED Completed
10/12/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Empire Pizza & Pub – Expansion and Exterior Façade work
Development Package (1st Review)
DP21-0254

TRANSMITTAL DATE: October 12, 2021

DUE DATE: October 19, 2021

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is September 16, 2022.

CONTENT REQUIREMENTS

1. COMMENT: 2-06.4.3 – Provide the development package case number, DP21-0254, adjacent to the title block on all sheets.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

2. COMMENT: 2-06.4.7.A.6.a – As this site is located within the Downtown core and the Rio Nuevo Area (RNA) Historic and RNA review are required. Once the reviews are complete and approved provide a general note stating the case number, date of approval, and if applicable any conditions of approval. Also provide the case numbers adjacent to the title block on all sheets.

3. COMMENT: 2-06.4.7.A.6.a – Under general notes you list “DOWNTOWN INFILL INCENTIVE DISTRICE CASE NUMBER” are you planning on using the IID, if not remove this from the note.

2-06.4.7.A.8 - For development package documents provide:

4. COMMENT: 2-06.4.7.A.8.c – Provide an expansion calculation for all proposed use areas, this includes the existing & proposed patio expansions. Zoning was not able to find permits for the “EXISTING (ONSITE) PATIO 225 SF and the PATIO (E) TRE 486 SF (DINING AREA). Provide approved documentation.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

5. COMMENT: 2-06.4.9.H.5.a – Under “Parking” you state “VEHICLE PARKING TO BE MODIFIED PER OVERLAY PROCESS”. Per UDC Article 7.4.5.B.2.a.(2) expansions of less than 1,000 sq. ft of less than 25% of the existing gross floor area, which ever is less, no additional vehicle or bicycle parking is required. As it appears the expansion is less than 1,000 sq. ft no additional parking is required and therefore a modification would not be required.

6. COMMENT: 2-06.4.9.Q – Show the limits of the PATIO (E) TRE 486 SF (DINING AREA) on the plan.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov.

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
10/19/2021 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
10/19/2021 AWARNER1 LANDSCAPE REVIEW Passed
11/02/2021 SBEASLE1 COT NON-DSD TRAFFIC Approved Building might need to have fire sprinklers installed throughout and under the new converted patio. DP does not show occupant load and or occupancy type. Please contact TFD for further information.

Jennifer Peel-Davis
520-837-7033
Jennifer.Peel-Davis@Tucsonaz.gov
11/02/2021 SBEASLE1 COT NON-DSD TRAFFIC Approved Email from: David Stiffey
To: CDRC
Tue 11/2/2021 8:05 AM

Approved. No comments.
11/03/2021 JPEELDA1 COT NON-DSD FIRE Approv-Cond Building might need to have fire sprinklers installed throughout and under the new converted patio. DP does not show occupant load and or occupancy type. Please contact TFD for further information.

Jennifer Peel-Davis
520-837-7033
Jennifer.Peel-Davis@Tucsonaz.gov
11/05/2021 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change email from: COTDSDPermits
To: Chuck Meyer
Fri 11/5/2021 2:39 PM

Returned for Corrections: DP21-0254
DESCRIPTION: Site - Empire Pizza and Pub. Expansion of use area into adjacent tenant space. 137 E CONGRESS ST

FEES DUE: $ 511.50
Please pay at a minimum, the REVIEW category fees.
A payment is required before your next submittal.

ONLINE PAYMENT
If amount doesn't match "Fees Due", check back in a few hours
https://www.tucsonaz.gov/pdsd/fees
1- Click on: Pay Planning & Permit Fees
2- Enter Permit Nbr, example: dp20-0000
(not case-sensitive but a hyphen-dash- is needed)
3- Business/Individual Name: Leave this field blank
4- "Continue"
5- In the Pay column - check the boxes
6- "Continue"

SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab and you will see different sections
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

INCLUDE IN RESUBMITTAL
1) Comment Response Letter (your response to REQUIRES CHANGE comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

Please title your SECOND submittal documents according to this example: 2_Comment Response Letter

FILEDROP for Resubmittal
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- Select "Existing Application"
- In the "Permit Number" field, enter the number and, if applicable, any notes for our staff


Thank you.
Sharon Beasley, Building Permit Specialist

City of Tucson, Planning and Development Services
Email: COTDSDpermits@TucsonAz.gov
(disregard the email response that will be sent automatically)