Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: DP21-0243
Parcel: 13214024E

Address:
810 E BENSON HY

Review Status: Completed

Review Details: DEV PKG - OK TO SUBMIT

Permit Number - DP21-0243
Review Name: DEV PKG - OK TO SUBMIT
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/24/2021 SBEASLE1 START PLANS SUBMITTED Completed
10/10/2021 ELISA HAMBLIN ZONING REVIEW Reqs Change Development Package (1st Review)
DP21-0243; 810 E Benson Hy

October 11, 2021

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is September 9, 2022.

1. 2-06.4.1 - The name, mailing and email addresses, and phone number of the primary property owner of the site, the developer of the project, registrant(s), and other person(s), firm(s), or organization(s) that prepared the development package documents shall be provided on the right half of the cover sheet.

2. 2-06.4.3 - Provide the relevant case numbers DP21-0243 adjacent to the title block on each sheet.

3. 2-06.4.4 - The project-location map to be located on the first sheet of the development package in the upper right corner, shall cover approximately one square mile, be drawn at a minimum scale of three inch equals one mile, and show the subject property approximately centered within the one square mile area; Identify major streets and regional watercourses within the square mile area and all streets that abut the subject property; and, Section, township, and range; section corners; north arrow; and the scale will be labeled.

4. 2-06.4.7.A.1 - List as a general note: "Existing zoning is C-2."

5. 2-06.4.7.A.2 - List the gross area of the site/subdivision by square footage and acreage.

6. 2-06.4.7.A.4 - Identify the existing and proposed use of the property as classified per the UDC. List all UDC sections applicable to the proposed uses. It is unclear from the plan whether the existing use is a hotel/motel or an apartment complex. Clarification is needed.

7. 2-06.4.9.H.5.a - Show all motor vehicle off-street parking spaces provided, fully dimensioned. As a note, provide calculations on the number of spaces required (include the ratio used) and the number provided, including the number of spaces required and provided for the physically disabled. The drawing should indicate parking space locations for the physically disabled. A typical parking space detail shall be provided for both standard parking spaces and those for the physically disabled. It unclear whether the parking calculations on the plan are based on the hotel/motel use or an apartment complex. Clarification is needed. If the proposed bicycle parking is removing parking, demonstrate parking requirements are still met.

8. 2-06.4.9.Q - Provide the square footage and the height of each commercial, industrial, or business structure and the specific use proposed within the footprint of the building(s).

If you have any questions about this transmittal, please contact me at Elisa.Hamblin@tucsonaz.gov.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
10/11/2021 SBEASLE1 ZONING-DECISION LETTER WRITE DECISION LETTER Reqs Change Email from: COTDSDPermits
To: Jr. Patel
Mon 10/11/2021 8:37 AM

Returned for Corrections: DP21-0243

DESCRIPTION: Site: Apartment complex. Install a bicycle rack. 810 E BENSON HY

FEES DUE: $ 99.00

ONLINE PAYMENT
** If amount doesn't match "Fees Due", check back in a few hours **
https://www.tucsonaz.gov/pdsd/fees
1- Click on: Pay Planning & Permit Fees
2- Enter Permit Nbr dp21-0243
3- Business/Individual Name: Leave this field blank
4- "Continue"
5- In the Pay column - check the boxes
6- "Continue"

REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab and you will see different sections
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

INCLUDE IN RESUBMITTAL
1) Comment Response Letter (your response to the Zoning review comments)
2) Plan Set
3) Any other documents requested by review staff

FILEDROP for Resubmittal
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- Select "Existing Application"
- In the "Permit Number" field, enter dp21-0243 and, if applicable, any notes for our staff

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson, Planning and Development Services
Email for Development Pkgs: COTDSDpermits@TucsonAz.gov
(disregard the email response that will be sent automatically)