Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: DP21-0216
Parcel: 10510059C

Address:
4267 N 4TH AV

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP21-0216
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/01/2021 SBEASLE1 START PLANS SUBMITTED Completed
09/15/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: San Junipero Townhomes
Development Package (1st Review)
DP21-0216

TRANSMITTAL DATE: September 15, 2021

DUE DATE: September 25, 2021

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is August 23, 2022.

CONTENT REQUIREMENTS

1. COMMENT: 2-06.4.3 – Provide the development package case number, DP21-0216, adjacent to the title block on all sheets.

2-06.4.7.A.8 - For development package documents provide:

2. COMMENT: 2-06.4.7.A.8.a – Provide the floor area for each building.

3. COMMENT: 2-06.4.7.A.8.b – Provide a lot coverage calculation on the plan, see UDC Article 6.4.3 and Table 6.3-2A.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

4. COMMENT: 2-06.4.9.H.5.a – Within the vehicle parking space calculation provide the number of required/provided accessible vehicle parking spaces and include the number of van accessible required/provided. See 2018 IBC Table 1106.7 for requirements.

5. COMMENT: 2-06.4.9.H.5.a – Provide a typical parking space detail for a standard parking space.

6. COMMENT: 2-06.4.9.H.5.d – Demonstrate on the plan or detail how the requirements of UDC Article 7.4.9.B.1.e are met.

7. COMMENT: 2-06.4.9.O – The street perimeter yard setback is not correct. This site does not quality for developing area setback therefore is required to meet the requirements of UDC Article 6.4.5.B.1.a. Perimeter yard setbacks are based on a measurement from design grade to the highest point of the wall, see Unified Development Code (UDC) Article 6.4.5.b & Figure 6.4.5-A. Based on the provided elevation and the 18’-10” shown plus 6” to grade the required street perimeter yard setback is 29’-0”, proposed setback for the northeast building is 26.7’ a Design development Option (DDO) will need to be submitted and approved prior to approval of this DP. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov.

8. COMMENT: 2-06.4.9.R – Clearly demonstrate that there is an accessible route to all buildings on site, see TSM Section 7-01.3.2.

9. COMMENT: 2-06.4.9.W - Indicate the locations and types of proposed signs (wall, free-standing, pedestal) to assure there are no conflicts with other requirements and that minimal locational requirements can be met. Also provide a general note on the plan stating “ALL SIGNS REQUIRE SEPARATE PERMITS”.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov.

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
09/20/2021 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Lots 1, 2, and 8 are more than 12-inches above the next upstream manhole (MH #5) and may not have a backwater valve. Reference: Section 714.1, IPC 2018, as amended by the City of Tucson.
2. Lot 5 is less than 12-inches above the next upstream manhole (MH#4) and will require the installation of a backwater valve. Reference: Section 714.1, IPC 2018, as amended by the City of Tucson.
09/22/2021 JPEELDA1 FIRE REVIEW Reqs Change IFC 2018, Appendix D D107.1 One-or two dwelling residential developments shall be provided with two access roads and or meet the exceptions
IFC 2018, Appendix D D103.4 Dead Ends. Dead end roads in excess of 150' shall be provided with a turn around
Hydrant Locations: IFC 2018 Appendix C & IFC 507.5.1 shall be met and hydrants shown on the drawings
TFD also needs to know the building heights at the parapet.

Questions:
Jennifer Peel-Davis
Jennifer.Peel-Davis@Tucsonaz.gov
520-837-7033
09/29/2021 AWARNER1 LANDSCAPE REVIEW Reqs Change CDRC TRANSMITTAL
TO: Planning and Development Services Department, Plans Coordination
FROM: Anne Warner, PLA
PDSD Landscape/Native Plant Preservation Section

PROJECT: San Junipero
ACTIVITY NO: DP21-0216
Address: 4267 N 4th Ave
Zoning: R-2
Existing Use: Single family
Proposed Use: Multifamily

TRANSMITTAL DATE: September 29, 2021
DUE DATE: September 24, 2021
COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Landscape Review Section comments were addressed.
This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting.
1. UDC 2-10.4.1 Identification and Descriptive Data
A. All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.

Ensure that Zoning and Engineering comments are addressed prior to landscape section approval.

2. Please label the existing and future rights of way for 4th Ave, UDC 7.6.4.C.2.a.

3. A 5’ screen is required along the street border on 4th Ave to shield views of the parking area. TABLE 7.6.4-1: LANDSCAPE BORDER (SECTION 7.6.4.C) AND SCREENING STANDARDS (SECTION 7.6.5)

4. Per Admin. Manual 2-10-4.2.D, provide page/detail reference to civil drawings/details that show bike racks, walkways, and screening/retaining walls on landscape plans.

5. Provide a maintenance schedule for the landscape and irrigation for this project. UDC 2-10-4.2.A.4.

6. Identify the point of drainage off roof areas, amount of flow, and disposition of flow.

7. Indicate the ground treatment in all planting areas on the landscape plan.

8. While the trees in the parking lot meet the 40’ trunk to parking space requirement, this does not meet the intent of the requirement. The intent is to provide as much shade on the asphalt as possible, and to do that the length between islands should be less than 7 spaces and trees located so that they provide shade on the asphalt.

9. Trees are to be distributed evenly throughout the parking area, UDC 7.6.4.1.B.1.

10. The parking area along 4th Ave requires additional trees, only 50% of the trees in the border can be counted towards the parking area tree requirement. These trees are providing no shade for the parking area revise locations or add a parking island.

11. A tree is required in the 4 space parking area to provide shade, please add.

12. Ensure that trees in vehicular use areas are planted within and adjacent to parking so that they afford the greatest amount of shade in paved areas, UDC Technical Standards Manual 5-01-.3.2 and UDC 7.6.4.B.1.a.

13. Please add/call out soil moisture gauge/tensiometers and rain shut-off device on irrigation plans and details. UDC 4.2.A.

14. Identify water meter and POC on irrigation plan.

15. Show on-site location of temporary plant nursery holding area or indicate if they will be transplanted directly to final location. Administrative Manual 2-11.4.5. Please include method and schedule for plant irrigation in holding area.

16. Add the following notes to the Native Plant Preservation Plan
a. UDC 7.7.5.4. Fencing is required during construction for all undisturbed areas of Protected Native Plants and for individual Protected Native Plants to be preserved-in-place.
b. The site developer must include language in all contracts with contractors about the importance of staying out of all areas and away from all individual Protected Native Plants to be preserved-in-place.

17. Add the following notes to the Native Plant Preservation Plan, UDC 7.7.5.5 On-site monitoring of all aspects of site clearing, grading, plant protection, preservation, salvage, and mitigation must be provided during project construction at the expense of the developer. The monitor must provide periodic progress reports to the developer outlining the status of work accomplished and any problems encountered. A copy of these reports must be submitted to the PDSD for the project file.

18. UDC 7.7.5.6. The monitor is responsible for an assessment of the condition of the site’s plants one year after the final inspection has been performed on the site. Copies of the report must be submitted to the site’s owner/developer and to PDSD.


RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package

YOUR NEXT STEPS: Submit documents to the Filedrop
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
Select "Existing Application"
1) Comment Response Letter (your response to
the reviewer's Requires changes comments)
2) Plan Set (or individual sheets)
3) Any other items requested by review staff

If you have any questions, please contact me at anne.warner@tucsonaz.gov
09/29/2021 SBEASLE1 PIMA COUNTY - ADDRESSING PIMA COUNTY - ADDRESSING Reqs Change (The ATTACHED PDF mentioned below can be viewed in PRO's "Documents", titled: "Pima Co Addressing Review Comments, 09.27.21")

Email from: Robin Freiman <Addressing@pima.gov>
To: CDRC
Cc: Erin Harris
Mon 9/27/2021 4:51 PM

San Junipero Townhomes, 1st submittal review, DP21-0216, is being Returned for Corrections by Pima County Addressing. The attached pdf contains Addressing’s comments.

Please let me know if you have any questions. Thank you,

Robin Freiman, Addressing Official

Pima County Development Services Department
201 N Stone AV – 1st Floor
Tucson, AZ 85701
(520) 724-7570
11/15/2021 SBLOOD1 ENGINEERING REVIEW Reqs Change 1. Provide waste stream calculations on plans per TSM section 8-01.8.0.
2. Provide a barrier free pedestrian circulation from each building to N 4th Av per TSM Section 7-01.3.2.
3. Detail 4 on sheet 8 is a duplicate of detail 11, double check to make sure that is right and revise if necessary.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
11/19/2021 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Email from: COTDSDPermits
To: Erin Harris
Fri 11/19/2021 10:02 AM

Returned for Corrections: DP21-0216

DESCRIPTION: Site/Grading/Swppp - San Junipero, multi-family. 4267 N 4TH AV

FEE BALANCE: $ 3,974.70
Please pay at a minimum, the REVIEW category fees.
A payment is required before your next submittal.

ONLINE PAYMENT
If amount doesn't match "Fees Due", check back in a few hours
https://www.tucsonaz.gov/pdsd/fees
1- Click on: Pay Planning & Permit Fees
2- Enter Permit Nbr, example: dp20-0000
(not case-sensitive but a hyphen-dash- is needed)
3- Business/Individual Name: Leave this field blank
4- "Continue"
5- In the Pay column - check the boxes
6- "Continue"

SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab to see different sections
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

INCLUDE IN RESUBMITTAL
1) Comment Response Letter (your response to REQUIRES CHANGE comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

Please title your SECOND submittal documents according to this example: 2_Comment Response Letter

FILEDROP for your Resubmittal
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- Select "Existing Application"
- In the "Permit Number" field, enter the number and, if applicable, any notes for our staff


Thank you.
Sharon Beasley, Building Permit Specialist

City of Tucson, Planning and Development Services
Email: COTDSDpermits@TucsonAz.gov
(disregard the email response that will be sent automatically)