Permit Review Detail
Review Status: Completed
Review Details: DEV PKG
Permit Number - DP21-0215
Review Name: DEV PKG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/01/2021 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 09/10/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: Bandit BBQ Development Package (1st Review) DP21-0215 TRANSMITTAL DATE: September 10, 2021 DUE DATE: September 21, 2021 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is August 23, 2022. CONTENT REQUIREMENTS 1. COMMENT: 2-06.4.3 – Provide the development package case number, DP21-0215, adjacent to the title block on all sheets. 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. 2-06.4.7.A - Zoning and Land Use Notes 2. COMMENT: 2-06.4.7.A.4 – The proposed uses, “ALCOHOLIC BEVERAGE SERVICE” & “FOOD SERVICE” do not match the uses listed in the vehicle & bicycle parking calculation, clarify. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 3. COMMENT: 2-06.4.9.H.5.a – The vehicle parking space requirement cannot be verified until comment 2 is addressed. 4. COMMENT: 2-06.4.9.H.5.a – The Janitorial Supply use listed is not correct. It is not three (3) separate uses therefore only has one parking ratio. If Zoning is not mistaken the primary use is Business Equipment Supply and Wholesaling and would be parked as such. 5. COMMENT: 2-06.4.9.H.5.d - The bicycle parking space requirement cannot be verified until comment 2 is addressed. 6. COMMENT: 2-06.4.9.H.5.d – Based on the layout of the bicycle parking shown on sheet 5 show the required 2’-6” dimension between the rack and bike lockets, see UDC Article 7.4.9.B.2.g. 7. COMMENT: 2-06.4.9.L – The proposed ‘INGRESS/EGRESS AND PARKING EASMENT AGREEMENT” will need to be recorded prior to approval of this plan. 8. COMMENT: 2-06.4.9.O – As the Bandit building is existing and no expansion of this building is proposed perimeter yard setbacks are an issue, a DDO is not required for the setbacks. 9. COMMENT: 2-06.4.9.O – Provide setback dimension from the proposed outdoor seating canopy to the edge of travel lane along Dodge. 10. COMMENT: 2-06.4.9.R – Provide sidewalk width dimensions for all sidewalks. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov. To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 09/16/2021 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 09/24/2021 | SBEASLE1 | COT NON-DSD | REVIEW | Approved | Email from: Eric.Latto@TucsonAz.gov To: CDRC Fri 9/24/2021 12:04 PM Bea and I have reviewed this application and see no issues with the development plans. |
| 09/27/2021 | SBEASLE1 | COT NON-DSD | TRAFFIC | Approved | Email from: David Stiffey To: CDRC Mon 9/27/2021 8:25 AM Approved. No Comments. |
| 09/28/2021 | AWARNER1 | LANDSCAPE | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Planning and Development Services Department, Plans Coordination FROM: Anne Warner, PLA PDSD Landscape/Native Plant Preservation Section PROJECT: Bandit BBQ ACTIVITY NO: DP21-0215 Parcels: 125-11-0710,-073A Zoning: C-2 Existing Use: Retail and food service Proposed Use: Retail and food service TRANSMITTAL DATE: September 28, 2021 DUE DATE: September 21, 2021 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Landscape Review Section comments were addressed. This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting. 1. UDC 2-10.4.1 Identification and Descriptive Data A. All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan. Ensure that Zoning and Engineering comments are addressed prior to landscape section approval. 2. Please label the existing and future rights of way for Speedway and Dodge Blvd, UDC 7.6.4.C.2.a. 3. Per Admin. Manual 2-10-4.2.D, provide page/detail reference to civil drawings/details that show bike racks, walkways, and screening/retaining walls on landscape plans. 4. Provide a maintenance schedule for the landscape and irrigation for this project. UDC 2-10-4.2.A.4. 5. Identify the point of drainage off roof areas, amount of flow, and disposition of flow. Show curb inlets for water to enter planting areas. 6. Please screen or turn off the plant layer on the Water Harvesting plan and add flow arrows for clarity. 7. While the trees in the parking lot meet the 40’ trunk to parking space requirement, this does not meet the intent of the requirement. The intent is to provide as much shade on the asphalt as possible, and to do that the length between islands should be less than 7 spaces. Please relook at parking area trees. UDC Technical Standards Manual 5-01-.3.2 and UDC 7.6.4.B.1.a. 8. Please add/call out soil moisture gauge/tensiometers and rain shut-off device on irrigation plans and details. UDC 4.2.A. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package YOUR NEXT STEPS: Submit documents to the Filedrop https://docs.tucsonaz.gov/Forms/tucsonpermitapp Select "Existing Application" 1) Comment Response Letter (your response to the reviewer's Requires changes comments) 2) Plan Set (or individual sheets) 3) Any other items requested by review staff If you have any questions, please contact me at anne.warner@tucsonaz.gov |
| 09/28/2021 | JPEELDA1 | COT NON-DSD | FIRE | Approved | |
| 11/09/2021 | SBLOOD1 | ENGINEERING | REVIEW | Approved | |
| 11/11/2021 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | Email from: COTDSDPermits to: lisa bowers Thu 11/11/2021 4:02 PM Returned for Corrections: DP21-0215 DESCRIPTION: Site/Grading/Swppp - Bandit BBQ. Expand existing restaurant, outdoor seating and kitchen. Fee Balance: $0 (zero) SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab to see different sections - Reviews section - click on REVIEW DETAILS - Documents section - click on VIEW INCLUDE IN RESUBMITTAL 1) Comment Response Letter (your response to REQUIRES CHANGE comments) 2) Plan Set (all pages, full set, even if no changes were made) 3) Any other documents requested by review staff Please title your SECOND submittal documents according to this example: 2_Comment Response Letter FILEDROP for Resubmittal https://docs.tucsonaz.gov/Forms/tucsonpermitapp - Select "Existing Application" - In the "Permit Number" field, enter the number and, if applicable, any notes for our staff Sharon Beasley, Building Permit Specialist City of Tucson, Planning and Development Services Email: COTDSDpermits@TucsonAz.gov (disregard the email response that will be sent automatically) |