Permit Number: DP21-0214
Parcel: 132130730

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP21-0214
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/14/2022 SBEASLE1 START PLANS SUBMITTED Completed
03/11/2022 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Costco at Tucson Marketplace – Parking Expansion
Development Package (3rd Review)
DP21-0214

TRANSMITTAL DATE: March 11, 2022

DUE DATE: March 14, 2022

Response to Zoning comments were only provided for comments 3 & 4. COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is September 05, 2022.

1. Zoning acknowledges your response but at this time nothing has been submitted. There are two options: 1) Wait for approval until the plat has been submitted and recorded. 2) Remove the property line from the plans and Zoning can approve. COMMENT: 2-06.4.9.E - It appears that some type of land split is proposed and the original block “Block 9” was created via plat, The Bridges Blocks 1 – 15, and block 9 has already be split once at a minimum a minor subdivision will be required. The subdivision is a separate submittal from the development package.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov.

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
03/16/2022 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Email from: COTDSDPermits
To: Andrea Urbas
cc: Terry Odle
Wed 3/16/2022 1:17 PM

REVIEW NOTICE
Returned for Corrections: DP21-0214

DESCRIPTION: Site - Costco. Expand parking lot. 1650 E TUCSON MARKETPLACE BL

Fee Balance: $0 (zero) Thank you for the payment.

YOUR NEXT STEPS
1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab to see different sections
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

2. UPLOAD A RESUBMITTAL and include:
1) Comment Response Letter (your response to REQUIRES CHANGE comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

Please title your FOURTH submittal documents according to this example: 4_Comment Response Letter

FILEDROP:
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- Select "Existing Application"
- In the "Permit Number" field, enter the number and, if applicable, any notes for our staff
- Select "PLANS" for all documents for quicker downloading of your documents on our end

Thank you.
Sharon Beasley, Building Permit Specialist

City of Tucson, Planning and Development Services
Email: COTDSDpermits@TucsonAz.gov