Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP21-0189
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/30/2021 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 10/21/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: Raising Cane’s - 1800 W Valencia Development Package (2nd Review) DP21-0189 TRANSMITTAL DATE: October 21, 2021 DUE DATE: October 26, 2021 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is July 19, 2022. 2-06.4.7.A.8 - For development package documents provide: 1. This comment was not addressed. The original building, Lowes, was built in 1994, 1st expansion of building area was in 2001 the area you have called “RETAIL PAD, formally Radio Shack, was the 1st expansion and now Raising “Canes is the 2nd expansion. Provide a cumulative expansion calculation on the plan. COMMENT: 2-06.4.7.A.8.c – Provide a building area expansion calculation on the plan. Per UDC Article 7.4.3.E.3 Expansions as noted in Section 7.4.3.E.1 and 2 are cumulated over time from April 1, 1969, that said the expansion calculation shall include the former Radio Shack building and any other expansions of the Lowes. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov. To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 10/21/2021 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. The minimum slope for drainage piping upstream of a grease interceptor is 2%. Reference: Section 704.1, IPC 2018. [Initial comment: The minimum slope for a 3" to 6" building sewer is 1/8" per foot (approximately 1%). Reference Section 704.1, IPC 2018.] 2. The rim elevation of the next upstream sanitary manhole (2472.87) is less than 12" below the first floor elevation (2473.00). Provide a backwater valve per Section 714.1, IPC 2018, as amended by the City of Tucson. [Initial comment: Provide the rim elevation of the next upstream sanitary manhole. Determine the need for a backwater valve per Section 714.1, IPC 2018, as amended by the City of Tucson.] 3. Keynote #5 calls out, "1-inch each hot and cold water connection" to the trash enclosure and the plan shows a pipe length of 33-feet. The distance noted in Table C404.5.1, IECC 2018, is measured from the hot water source to the appliance. For a 1-inch pipe, the maximum distance is 13-feet. [Initial comment: Explain how the hot water service to the trash enclosure will comply with Section C404.5, IECC 2018.] 4. The hot water supply to the hand washing station near the south order board needs to comply with the distance requirement of Table C404.5.1, IECC 2018. [Initial comment: Clarify what appears to be 1-inch hot and cold water supplies (C15, domestic water note #5) to the south order board. Reference: Section 107.2.1, IBC 2018.] |
| 10/28/2021 | AWARNER1 | LANDSCAPE | REVIEW | Approved | |
| 10/29/2021 | SBLOOD1 | ENGINEERING | REVIEW | Approved | |
| 11/17/2021 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | Email from: COTDSDPermits To: Heather Roberts Wed 11/17/2021 2:50 PM Returned for Corrections: DP21-0189 DESCRIPTION: Site/Grading - Raising Canes Chicken Fingers restaurant with double drive-thru. 1800 W VALENCIA RD Fee Balance: $0 (zero) Thank you for the payment. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab to see different sections - Reviews section - click on REVIEW DETAILS - Documents section - click on VIEW INCLUDE IN RESUBMITTAL 1) Comment Response Letter (your response to REQUIRES CHANGE comments) 2) Plan Set (all pages, full set, even if no changes were made) 3) Any other documents requested by review staff Please title your THIRD submittal documents according to this example: 3_Comment Response Letter FILEDROP for your Resubmittal https://docs.tucsonaz.gov/Forms/tucsonpermitapp - Select "Existing Application" - In the "Permit Number" field, enter the number and, if applicable, any notes for our staff Thank you. Sharon Beasley, Building Permit Specialist City of Tucson, Planning and Development Services Email: COTDSDpermits@TucsonAz.gov (disregard the email response that will be sent automatically) |
| 11/17/2021 | SBEASLE1 | COT NON-DSD | TRAFFIC | Reqs Change | Email from: David.Stiffey@TucsonAz.gov To: CDRC Wed 11/17/2021 11:20 AM 1. Sheet C05- Please add the "dimensions" for the sight visibility triangles. (Near side 345 Ft. Far side is the pedestrian triangle.) David Stiffey City of Tucson |