| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/30/2021 | ELISA HAMBLIN | ZONING | REVIEW | Approved | |
| 12/01/2021 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | The new cleanout is located 100-feet from the next cleanout, but the developed pipe length between cleanouts must include the distance between the rim of the new cleanout and the invert of the building sewer below the new cleanout. Provide the rim elevation of the new cleanout and the invert of the building sewer below the new cleanout. [Initial comment: The maximum distance between cleanouts shall be 100-feet, measured along the developed pipe length. Reference: Section 708.1.1, IPC 2018.] |
| 12/01/2021 | AWARNER1 | LANDSCAPE | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Planning and Development Services Department, Plans Coordination FROM: Anne Warner, PLA PDSD Landscape/Native Plant Preservation Section PROJECT: The Humane Society ACTIVITY NO: DP21-0183, 2nd submittal Address: 651 W Roger Rd Parcel: 106-05-011C, -010A Zoning: I-1 Existing Use: Residential, Office, previously graded land Proposed Use: Commercial Services, Administrative Office TRANSMITTAL DATE: December 1, 2021 DUE DATE: December 21, 2021 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Landscape Review Section comments were addressed. This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting. 1. UDC 2-10.4.1 Identification and Descriptive Data A. All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan. Ensure that Zoning and Engineering comments are addressed prior to landscape section approval. 2. This comment was not adequately addressed. Solely using the 40' trunk to parking space requirement or placing trees only along the edge of a parking area does not meet the intent of the UDC. The intent is to provide as much shade on the asphalt as possible, and the requirement is 1 tree per 4 parking spaces; trees are expected to be placed within the parking area itself. Trees are to be distributed evenly throughout the parking area, UDC 7.6.4.1.B.1, UDC Technical Standards Manual 5-01-.3.2 and UDC 7.6.4.B.1.a. Please integrate trees into parking areas. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Development Package If you have any questions, please contact me at anne.warner@tucsonaz.gov |
| 12/20/2021 | SBEASLE1 | ZONING-DECISION LETTER | WRITE DECISION LETTER | Reqs Change | Email from: COTDSDPermits To: Jason Morse Mon 12/20/2021 12:25 PM REVISION REVIEW NOTICE Returned for corrections, DP21-0183 DESCRIPTION: Site - Humane Society. Fence, bicycle rack, sidewalk, access ramp, wall, etc. 635 W ROGER RD FEE BALANCE: $0 (zero) Thank you for the payment VIEW the review comments and documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab - Reviews - click on Review Details - Documents - click on View to the right of each document YOUR NEXT STEPS: Submit documents to the Filedrop https://docs.tucsonaz.gov/Forms/tucsonpermitapp Select "Existing Application" 1) Comment Response Letter (your response to the reviewer's Requires changes comments) 2) Plan Set (or individual sheets) 3) Any other items/documents requested by review staff Thank you. Sharon Beasley, Building Permit Specialist City of Tucson, Planning and Development Services Email: COTDSDpermits@TucsonAz.gov (disregard the email response that will be sent automatically) |
| 12/20/2021 | SBEASLE1 | COT NON-DSD | TRAFFIC | Reqs Change | Email from: David.Stiffey@tucsonAz.gov To: CDRC Mon 12/20/2021 11:22 AM 1. With property drainage to the north and north east, please provide under sidewalk scuppers David Stiffey City of Tucson |