Permit Number: DP21-0182
Parcel: 12511246C

Address:
626 N DODGE BL

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP21-0182
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/15/2021 SBEASLE1 START PLANS SUBMITTED Completed
08/02/2021 JPEELDA1 FIRE REVIEW Approved
08/11/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: 626 N Dodge Blvd – Site Modifications
Development Package (1st Review)
DP21-0182

TRANSMITTAL DATE: August 11, 2021

DUE DATE: August 12, 2021

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is July 8, 2022.

CONTENT REQUIREMENTSCOMMENT:

1. COMMENT: 2-06.4.2.D - The page number and the total number of pages in the package (i.e., sheet xx of xx).

2. COMMENT: 2-06.4.3 – Provide the development package case number, DP21-0182, adjacent to the title block on all sheets.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

3. COMMENT: 2-06.4.9.H.5.a – Per UDC Article 7.4.6.D. and ICC A117.1, Section 502.5 demonstrate on the plan that the slope requirements are met.

4. COMMENT: 2-06.4.9.H.5.a – As the proposed accessible signs are located within a pedestrian way the minimum mounting height to the bottom of the lowest sign is 84”.

5. COMMENT: 2-06.4.9.R – Per TSM Section 7-01.3.2 and ICC A117.1, Section 405 demonstrate that the proposed ramp meets these requirements.

6. COMMENT: 2-06.4.9.R – Per TSM Section 7-01.4.1.F Sidewalks or pedestrian refuge areas cannot be located between any motor vehicle parking space and the PAAL providing access to that space. That said remove the stripped crosswalk the extends from the north side of the accessible access aisle and the stripped area shown running along the south side of the northern most parking from the plan.

If you have any questions about this transmittal, please contact Elisa Hamblin or Elisa.Hamblin@tucsonaz.gov.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
08/11/2021 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
08/19/2021 AWARNER1 LANDSCAPE REVIEW Passed
09/03/2021 SBLOOD1 ENGINEERING REVIEW Reqs Change 1. Detail 3 sheet G0.0. Note that minimum clearance from bottom of lowest sign to finished surface is 84" if the sign is located within a pedestrian circulation area. Update detail as needed.
2. Stripped crosswalk to trash enclosure can not run between any parking space and the PAAL that accesses it per Technical Standards Manual section 7-01.4.1.F. Revise site plan as needed.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
09/06/2021 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Email from: COTDSDPermits
To: E. Farkas
Cc: Pete Lee
Mon 9/6/2021 1:23 PM

Returned for Corrections: DP21-0182

DESCRIPTION: Site - 5th and Dodge apartment renovation. Parking spaces, bicycle parking, trash enclosure. (Owner is City of Tucson) 626 N DODGE BL

FEES DUE: $ 511.50
Please pay at a minimum, the REVIEW Fees.
A payment is required before your next submittal.

ONLINE PAYMENT
If amount doesn't match "Fees Due", check back in a few hours after it is updated.
https://www.tucsonaz.gov/pdsd/fees
1- Click on: Pay Planning & Permit Fees
2- Enter Permit Nbr, example: dp20-0000
(not case-sensitive but a hyphen-dash- is needed)
3- Business/Individual Name: Leave this field blank
4- "Continue"
5- In the Pay column - check the boxes
6- "Continue"

SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab and you will see different sections
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

INCLUDE IN YOUR RESUBMITTAL
1) Comment Response Letter
(your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

Please title your 2nd submittal documents according to this example: 2_Comment Response Letter, 09.01.21

FILEDROP for Resubmittal
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- Select "Existing Application"
- In the "Permit Number" field, enter the number and, if applicable, any notes for our staff


Thank you.
Sharon Beasley, Permit Specialist

City of Tucson, Planning and Development Services
Email for Development Pkgs: COTDSDpermits@TucsonAz.gov
(disregard the email response that will be sent automatically)