03/28/2022 SBEASLE1 START PLANS SUBMITTED Completed
04/14/2022 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Fry’s Fuel Center #58 – 4733 S Campbell Ave
Development Package (3rd Review)
DP21-0179

TRANSMITTAL DATE: April 14, 2022

DUE DATE: April 21, 2022

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is July 13, 2022.

CONTENT REQUIREMENTS

1. This comment was not addressed. The submitted plan set only has 12 sheets and all of the sheets show X of 18. Also, the drawing index shows 18 sheets. COMMENT: 2-06.4.2.D – The page number and the total number of pages is not correct on sheets L0.1 – L4.1.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

2. This comment was not addressed. Provide a copy of the recorded easement/agreement with the next submittal. COMMENT: 2-06.4.9.L – If the fuel center is not going to be part of the Fry’s shopping center as you are proposing access across the parcel to the south provide a copy of the recorded cross access easement/agreement with your next submittal.

If you have any questions about this transmittal, please contact Nicholas Ross at Nocholas.Ross@tucsonaz.gov.

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
04/15/2022 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Email from: COTDSDPermits
To: Caroline Park
Fri 4/15/2022 3:15 PM

REVIEW NOTICE
Returned for Corrections: DP21-0179

DESCRIPTION: Site/Grading - Fry's Fuel Center #58. 4733 S CAMPBELL AV

Fee Balance: $0 (zero) Thank you for the payment.

YOUR NEXT STEPS
1. SEE - ZONING - REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab to see different sections
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

2. Title your FOURTH submittal documents accordingly, example: 4_Comment Response Letter

3. UPLOAD A RESUBMITTAL to Filedrop:
1) Comment Response Letter (your response to REQUIRES CHANGE comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

- FILEDROP:
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- "Existing Application"
- "Permit Number" field: enter the number (and any notes for our staff)
- Select "PLANS" for all documents

Thank you.