Permit Number: DP21-0167
Parcel: 120052720

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP21-0167
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/09/2021 SBEASLE1 START PLANS SUBMITTED Completed
09/24/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Popeyes – 840 W Irvington Rd
Development Package (2nd Review)
DP21-0167

TRANSMITTAL DATE: September 24, 2021

DUE DATE: October 06, 2021

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is June 24, 2022.

CONTENT REQUIREMENTS

1. This comment was not addressed. COMMENT: 2-06.4.4.C – Label the sections corners on the required location map.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

2. This comment does not appear to have been addressed. Zoning was not able to find a land split that has been processed for this site. Provide copies of the approved land split and provided the case number adjacent to the title block on all sheets. COMMENT: 2-06.4.9.A – Based on the property lines shown of the plan there is some type of land split or subdivision planned. The number of lots proposed will determine what process will be required. This process will need to be completed prior to approval of this DP.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov.

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
10/04/2021 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
10/08/2021 AWARNER1 LANDSCAPE REVIEW Reqs Change CDRC TRANSMITTAL
TO: Planning and Development Services Department, Plans Coordination
FROM: Anne Warner, PLA
PDSD Landscape/Native Plant Preservation Section

PROJECT: Popeye’s
ACTIVITY NO: DP21-0167, 2nd submittal
Address: 840 W Irvington Rd
Parcel: 120-05-2720 (partial)
Zoning: C-2
Existing Use: shopping center pad
Proposed Use: Food Service

TRANSMITTAL DATE: October 8, 2021
DUE DATE: October 6, 2021

COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Landscape Review Section comments were addressed.
This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting.

1. A Commercial Rainwater Harvesting Plan requires 50% of stormwater be captured for landscape water needs. Water should be directed into landscape areas through scuppers, curb cuts that allows conveyance into these areas. UDC Technical Standards Manual – Section 4-01.0.0. Commercial Rainwater Harvesting

2. An irrigation plan and details are required per UDC Administration Manual 2-10.4.2.C and Technical Standards Manual Section 4-01.4.2, Irrigation Standards.

3. Grading, hydrology, and landscape plans must be integrated to make maximum use of site storm water runoff for supplemental on-site irrigation purposes. The landscape plan shall indicate use of all runoff, from individual catch basins around single trees to basins accepting flow from an entire vehicular use area or roof area. UDC 7.7.6.C.2

4. Identify the point of drainage off roof areas, amount of flow, and disposition of flow.

5. While the trees in the parking lot may meet the 40’ trunk to parking space requirement, this does not meet the intent of the requirement. The intent is to provide as much shade on the asphalt as possible, and the requirement is 1 tree per 4 parking spaces. Trees are to be distributed evenly throughout the parking area, UDC 7.6.4.1.B.1, UDC Technical Standards Manual 5-01-.3.2 and UDC 7.6.4.B.1.a.

6. Show all existing plants to remain undisturbed along Irvington Rd. All trees should remain in place if at all possible. Make sure to label all plants that will be removed. See your note under Landscape Removal.


RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package

YOUR NEXT STEPS: Submit documents to the Filedrop
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
Select "Existing Application"
1) Comment Response Letter (your response to
the reviewer's Requires changes comments)
2) Plan Set (or individual sheets)
3) Any other items requested by review staff

If you have any questions, please contact me at anne.warner@tucsonaz.gov
10/19/2021 SBLOOD1 ENGINEERING REVIEW Approved
10/21/2021 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Email from: COTDSDPermits
To: William F.
Thu 10/21/2021 9:52 AM

Returned for Corrections: DP21-0167

DESCRIPTION: Site/Grading/Swppp - Popeyes Restaurant. 840 W IRVINGTON RD

FEES DUE: $ 33.00 Building permit fee
(you may pay this now or later)

ONLINE PAYMENT
If amount doesn't match "Fees Due", check back in a few hours
https://www.tucsonaz.gov/pdsd/fees
1- Click on: Pay Planning & Permit Fees
2- Enter Permit Nbr, example: dp20-0000
(not case-sensitive but a hyphen-dash- is needed)
3- Business/Individual Name: Leave this field blank
4- "Continue"
5- In the Pay column - check the boxes
6- "Continue"

REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab and you will see different sections
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

INCLUDE IN RESUBMITTAL
1) Comment Response Letter (your response to any Requires Change comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

Please title your THIRD submittal documents according to this example: 3_Comment Response Letter

FILEDROP for Resubmittal
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- Select "Existing Application"
- In the "Permit Number" field, enter the number and, if applicable, any notes for our staff


Thank you.
Sharon Beasley, Permit Specialist

City of Tucson, Planning and Development Services
Email for Development Pkgs: COTDSDpermits@TucsonAz.gov
(disregard the email response that will be sent automatically)