Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: DP21-0158
Parcel: 129020870

Review Status: Completed

Review Details: DEV PKG - OK TO SUBMIT

Permit Number - DP21-0158
Review Name: DEV PKG - OK TO SUBMIT
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/22/2021 SBEASLE1 START PLANS SUBMITTED Completed
06/22/2021 ALEXANDRA HINES ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Freddy’s – 2744 E Broadway Blvd
Development Package (1st Review)
DP21-0158

TRANSMITTAL DATE: July 26, 2021

DUE DATE: July 23, 2021

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is June 21, 2022.

CONTENT REQUIREMENTS

1. COMMENT: 2-06.4.3 – Provide the development package case number, DP21-0158, adjacent to the title block on all sheets.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

2. COMMENT: 2-06.4.9.H.5 – Per UDC Article 7.4.6.F.2a.(2) show the required 1’-0” setback from the drive-through to the building.

3. COMMENT: 2-06.4.9.H.5 – Per UDC Article 7.4.7 show and dimension the required drive-through stacking spaces on the plan.

4. COMMENT: 2-06.4.9.H.5.d – Zoning acknowledge Keynote 20 but was not able to find the short-term bicycle parking on the plan.

5. COMMENT: 2-06.4.9.O – The street perimeter yard setbacks shown are not correct. Per the definition of Established Area Setback and that Broadway Blvd is an Arterial Street designated on the COT MS&R map this site qualifies for Developing are setbacks. Per UDC Article 6.4.5.C.2 and Figure 6.4.5.C-1 the required street perimeter yard setback for Broadway Blvd is based on an ADT of 1,000 or greater, and is 21’ or the height of the exterior wall, greater of the two, as measure from the back of curb. Based on a Zoning Administrators determination developing area and established area street setbacks cannot be mixed there for developing area setbacks are used for Treat Ave based on an ADT over 140 but less than 1,000 and is 21’ or the height of the exterior wall, greater of the two, as measure from the outside edge of the nearest adjacent travel lane.

6. COMMENT: 2-06.4.9.R – Near the northwest corner of the proposed building demonstrate that a parking vehicle will not reduce the sidewalk width to less than 4’-0”.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
06/22/2021 SBEASLE1 PIMA COUNTY - ADDRESSING PIMA COUNTY - ADDRESSING Passed Email from: <Addressing@pima.gov>
To: CDRC
Tue 6/22/2021 1:37 PM

This project does not require review by Pima County Addressing.
Thank you
Nicholas Jordan, Addressing Specialist

Pima County Development Services Department
201 N Stone AV – 1st Floor
Tucson, AZ 85701
(520) 724-9623
06/23/2021 LOREN MAKUS ENGINEERING REVIEW Needs Review
06/24/2021 SBEASLE1 ZONING-DECISION LETTER WRITE DECISION LETTER Completed