Permit Number: DP21-0148
Parcel: 13355231B

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP21-0148
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/17/2021 SBEASLE1 START PLANS SUBMITTED Completed
07/14/2021 JVINCEN1 FIRE REVIEW Approved
07/15/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Target – Drive Up Expansion
Development Package (1st Review)
DP21-0148

TRANSMITTAL DATE: July 15, 2021

DUE DATE: July 14, 2021

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is June 13, 2022.

CONTENT REQUIREMENTS

1. COMMENT: 2-06.4.2.D - The page number and the total number of pages in the package (i.e., sheet xx of xx) shall be provided within the tittle block on all sheets.

2. COMMENT: 2-06.4.3 – Provide the development package case number, DP21-0148, adjacent to the title block on all sheets.

3. COMMENT: 2-06.4.4 - The project-location map shall be drawn at a minimum scale of three-inch equals one mile.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

4. COMMENT: 2-06.4.7.A.4 - Identify the existing and proposed use of the property as classified per the UDC. List all UDC sections applicable to the proposed uses. This includes all uses shown on the plan.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

5. COMMENT: 2-06.4.9.F - All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined.

6. COMMENT: 2-06.4.9.H.5.a - As you are proposing a configuration change to existing vehicle parking space and it appears that you are eliminating vehicle parking spaces provide a revise vehicle parking space calculation on the plan. This calculation shall include the number of spaces required (include the ratio used) and the number provided, including the number of spaces required and provided for the physically disabled.

7. COMMENT: 2-06.4.9.H.5.a – The “DRIVE UP STRIPING” detail sheet 5 references “(PER PLAN)” for the vehicle parking space width dimension but there are no width dimension provided on the plan.

8. COMMENT: 2-06.4.9.H.5.a – On the “DRIVE UP STRIPING” detail sheet 5 there is not a width provided for the “RUBBER WHEEL STOP” provide the location dimension for the wheel stop based on UDC Article 7.4.6.H.3.

9. COMMENT: 2-06.4.9.H.5.a – On the “DRIVE UP STRIPING” detail sheet 5 it appears that the proposed “POST & PANEL SIGN” encroaches into the 2’-6” vehicle overhang. Clearly demonstrate that the 2’-6” overhang area remains clear.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
07/16/2021 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Email from: COTDSDPermits
To: Cassie Kussow
Fri 7/16/2021 10:07 AM

Returned for Corrections , DP21-0148
DESCRIPTION: Site - Target, parking lot restriping, signage, drive-up beacons. 9615 E OLD SPANISH TR

FEES DUE: $ 264.00
Please pay at a minimum, the REVIEW Fees. A payment is required before your next submittal.
ONLINE PAYMENT
If amount isn't correct, check back in a few hours after it is updated.
https://www.tucsonaz.gov/pdsd/fees
1- Click on: Pay Planning & Permit Fees
2- Enter Permit Nbr, example: dp20-0000
(not case-sensitive but a hyphen-dash- is needed)
3- Business/Individual Name: Leave this field blank
4- "Continue"
5- In the Pay column - check the boxes
6- "Continue"

INCLUDE IN YOUR RESUBMITTAL
1) Comment Response Letter
(your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

Please title your 2nd submittal documents according to this example: 2_Comment Response Letter, 07.01.21

FILEDROP
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
(Select "Existing Application", then permit number)

SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab and you will see different sections
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

Thank you.

Sharon Beasley, Permit Specialist

City of Tucson, Planning and Development Services
Email for Development Pkgs: COTDSDpermits@TucsonAz.gov
(disregard the email response that will be sent automatically)
Email for Building Permits: PDSDinquiries@TucsonAz.gov