Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: DP21-0145
Parcel: 10603054B

Address:
3250 N STONE AV

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP21-0145
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/06/2022 SBEASLE1 START PLANS SUBMITTED Completed
06/23/2022 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change The rim elevation of the next upstream sanitary manhole (MH 9858-71, 2335.56') is less than 12" below the first floor elevation (2336.16'). Provide a backwater valve per Section 714.1, IPC 2018, as amended by the City of Tucson. [Initial comment: Comment not addressed. [Initial comment: Provide the rim elevation of the next upstream sanitary manhole, MH 9858-71. Determine the need for a backwater valve per Section 714.1, IPC 2018, as amended by the City of Tucson.]
06/24/2022 STEVE SHIELDS ZONING REVIEW Denied PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Navajo Road Quad Plex
Development Package (3rd Review)
DP21-0145

TRANSMITTAL DATE: June 24, 2022

DUE DATE: June 24, 2022

As the scope of work has changed and you are now proposing a residential duplex a Development Package (DP) is not required. Withdraw this DP and submit for residential building review.

If you have any questions about this transmittal, please contact Nicholas Ross at Nicholas.Ross@tucsonaz.gov.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
06/24/2022 SSHIELD1 ENGINEERING REVIEW Denied See Zoning comments
06/24/2022 SSHIELD1 FIRE REVIEW Denied See Zoning comments
06/24/2022 SSHIELD1 LANDSCAPE REVIEW Denied See Zoning comments
06/24/2022 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Email from: COTDSDPermits
To: Charles Corrales
Fri 6/24/2022 3:25 PM

REVIEW NOTICE

This permit has been denied by Zoning for further review.
If any questions, please send an email to our Zoning staff:
Zone1.Desk@TucsonAz.gov

To withdraw this permit DP21-0145, we require only a short statement sent to email: COTDSDpermits@TucsonAz.gov

See Zoning review comments on PRO.

REVIEW NOTICE
Permit/Activity: DP21-0145

Project Description: Site/Grading - Navajo Road duplex.
3250 N STONE AV

Fee Balance: $0 (zero) Thank you for the payment.

YOUR NEXT STEPS
1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

FILEDROP for your residential building permit request:

https://docs.tucsonaz.gov/Forms/tucsonpermitapp
1- New applications for Building permits - select the appropriate "Submission Type" category.
2- After completing the required fields and submitting your documents, you will see the message below at the top of your page. Click on a button to save a copy of the online Application for your files.


Thank you.
Sharon Beasley, Certified Permit Technician

City of Tucson, Planning & Development Services Dept.
Email: COTDSDpermits@TucsonAz.gov
(for development packages, land splits, Thursday Presubmittal meetings)
Email: PDSDinquiries@TucsonAz.gov
(for building permits)