Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP21-0120
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/06/2021 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 10/21/2021 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 10/26/2021 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 10/27/2021 | JENNIFER STEPHENS | PIMA COUNTY | ADDRESSING | Approved | Email from: <Addressing@pima.gov> To: CDRC Wed 10/27/2021 12:57 PM 2nd Submittal: DP21-0120, Kadampa Meditation Center is Approved by Pima County Addressing. Thank you, Robin Freiman, Addressing Official Pima County Development Services Department 201 N Stone AV – 1st Floor Tucson, AZ 85701 (520) 724-7570 |
| 10/29/2021 | SBLOOD1 | ENGINEERING | REVIEW | Approved | |
| 11/02/2021 | AWARNER1 | LANDSCAPE | REVIEW | Reqs Change | PROJECT: Kadampa Meditation Center Expansion ACTIVITY NO: DP21-0120 Address: 5326 E Pima St Zoning: C-1 Existing Use: Religious use and Multi-family Proposed Use: Religious use and Multi-family TRANSMITTAL DATE: November 2, 2021 DUE DATE: October 27, 2021 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Landscape Review Section comments were addressed. This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting. 1. UDC 2-10.4.1 Identification and Descriptive Data A. All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan. Ensure that Zoning and Engineering comments are addressed prior to landscape section approval. 2. Add previous activity number DP14-0065 for reference for timely reviews. 3. There are three required trees that are missing along the street border, please add those to the landscape plan as well as a plant legend. 4. The existing street landscape border does not provide 50% vegetative cover, mostly because the shrubs have been pruned into shapes. Allow shrubs to grow naturally or add vegetation to achieve 50% coverage. 5. No vegetative ground cover is remaining, replant according to previous plans and add plants to new plans. 6. Parking calculations show 2 trees required, but only 1 provided, please add 1 tree on site to shade asphalt. 7. Provide a maintenance schedule for the landscape and irrigation for this project. UDC 2-10-4.2.A.4., please be specific. 8. ¾” gravel is mentioned on the landscape plan with a referral to the grading plan for more information, however there is no additional information there. Please indicate size, color and source of rock mulch. 9. Grading, hydrology, and landscape plans must be integrated to make maximum use of site storm water runoff for supplemental on-site irrigation purposes. The landscape plan shall indicate use of all runoff, from individual catch basins around single trees to basins accepting flow from an entire vehicular use area or roof area. UDC 7.7.6.C.2. The landscape and grading plans must match. 10. Identify the point of drainage off roof areas, amount of flow, and disposition of flow. 11. Retention/detention basins should be designed naturally and organically, whenever practicable. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package YOUR NEXT STEPS: Submit documents to the Filedrop https://docs.tucsonaz.gov/Forms/tucsonpermitapp Select "Existing Application" 1) Comment Response Letter (your response to the reviewer's Requires changes comments) 2) Plan Set (or individual sheets) 3) Any other items requested by review staff If you have any questions, please contact me at anne.warner@tucsonaz.gov |
| 11/08/2021 | JPEELDA1 | COT NON-DSD | FIRE | Approved | |
| 11/17/2021 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | Email from: COTDSDPermits To: Jeffrey Stanley Wed 11/17/2021 1:59 PM Returned for Corrections: DP21-0120 DESCRIPTION: Site/Grading: Kadampa Meditation Center, addition of a triplex to an existing development. 5326 E PIMA ST FEES DUE: $ 82.50 (additional review time by Fire Dept) ONLINE PAYMENT If amount doesn't match "Fees Due", check back in a few hours https://www.tucsonaz.gov/pdsd/fees 1- Click on: Pay Planning & Permit Fees 2- Enter Permit Nbr, example: dp20-0000 (not case-sensitive but a hyphen-dash- is needed) 3- Business/Individual Name: Leave this field blank 4- "Continue" 5- In the Pay column - check the boxes 6- "Continue" SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab to see different sections - Reviews section - click on REVIEW DETAILS - Documents section - click on VIEW INCLUDE IN RESUBMITTAL 1) Comment Response Letter (your response to REQUIRES CHANGE comments) 2) Plan Set (all pages, full set, even if no changes were made) 3) Any other documents requested by review staff Please title your THIRD submittal documents according to this example: 3_Comment Response Letter FILEDROP for your Resubmittal https://docs.tucsonaz.gov/Forms/tucsonpermitapp - Select "Existing Application" - In the "Permit Number" field, enter the number and, if applicable, any notes for our staff Thank you. Sharon Beasley, Building Permit Specialist City of Tucson, Planning and Development Services Email: COTDSDpermits@TucsonAz.gov (disregard the email response that will be sent automatically) |
| 11/17/2021 | SBEASLE1 | COT NON-DSD | TRAFFIC | Approved | Email from: David Stiffey To: CDRC Wed 11/17/2021 1:33 PM No further comments. |