Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: DP21-0120
Parcel: 12112401A

Address:
5326 E PIMA ST

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP21-0120
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/21/2021 SBEASLE1 START PLANS SUBMITTED Completed
05/24/2021 SBEASLE1 COT NON-DSD REVIEW Approved Email from: Christopher.Blue@tucsonaz.gov
To: CDRC
Fri 5/21/2021 5:20 PM

The Transit Services Division and Sun Tran have no comments.
Thank you.

Christopher Blue
Transit Services Coordinator
t + 15202609558
City of Tucson
06/03/2021 SBEASLE1 PIMA COUNTY ADDRESSING Reqs Change (The ATTACHED PDF mentioned below can be viewed online: www.TucsonAz.gov/Pro. See the Documents section.)

Email sent from: Robin Freiman <Addressing@pima.gov>
To: CDRC
Thu 6/3/2021 11:52 AM

Kadampa Meditation Center, DP21-0120, 1st submittal review is being Returned for Corrections by Pima County Addressing.
The attached pdf contains Addressing’s comments.
Please let me know if you have any questions.
Thank you,
Robin Freiman, Addressing Official

Pima County Development Services Department
201 N Stone AV – 1st Floor
Tucson, AZ 85701
(520) 724-7570
06/07/2021 JPEELDA1 COT NON-DSD FIRE Reqs Change Please show the distance as the hose lays from the closest hydrant to the furthest part of the new building. Distance shall be 400 or less or fire sprinklers shall be installed. If you have any questions please call or email me.
Jennifer.Peel-Davis@Tucsonaz.gov
520-837-7033
06/08/2021 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change The maximum distance between cleanouts shall be 100-feet, measured along the developed pipe length (e.g. with a cleanout rim at 90.5’ and an invert of 88.0’, the maximum distance to the next cleanout is 97.5’, not 115’). Reference: Section 708.1.1, IPC 2018.
06/11/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Kadampa Meditation Center – Triplex Addition
Development Package (1st Review)
DP21-0120

TRANSMITTAL DATE: June 11, 2021

DUE DATE: June 16, 2021

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is May 20, 2021.

CONTENT REQUIREMENTS

1. COMMENT: 2-06.4.3 – Provide the development package case number, DP21-0120, adjacent to the title block on all sheets.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

2. COMMENT: 2-06.4.7.A.4 – Provide the Use Specific Standard for the existing religious use in general note 3. Also add the multifamily use to general note 14.

2-06.4.7.A.8 - For development package documents provide:

3. COMMENT: 2-06.4.7.A.8.c – Provide a building expansion calculation on the plan.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

4. COMMENT: 2-06.4.9.H.5.a – Provide the number of bedrooms in each unit so that vehicle parking requirement can be verified.

5. COMMENT: 2-06.4.9.H.5.d – Until the number of bedrooms is provided, see comment 4, short- & long-term bicycle parking cannot be verified.

6. COMMENT: 2-06.4.9.H.5.d – Show the required long-term bicycle parking on the plan and provide a detail that matches the proposed location.

7. COMMENT: 2-06.4.9.H.5.d – The short-term bicycle parking detail on sheet does not match the location or layout shown on the plan.

8. COMMENT: 2-06.4.9.Q – Provide the height of the proposed triplex within the footprint of the building.

9. COMMENT: 2-06.4.9.Q – Within the footprint of the existing southern building you show it as “PROPOSED”. As this building is already constructed it should be shown as existing.

10. COMMENT: 2-06.4.9.Q – Based on current aerial photos there are three (3) small structures located south of the existing structures. If these structures are to remain show them on the DP along with the square footage and heights. If any of these structures are greater 200 sq. ft or larger provide documentation that they were permitted.

11. COMMENT: 2-06.4.9.R – At the west end of the turnaround there is a Keynote 21 that states “EXISTING CONCRETE CURB ACCESS RAMP”. Based on current aerial photo’s and the last approved development package there is no curb access ramp in this area.


If you have any questions about this transmittal, please contact Elisa Hamblin or Elisa.Hamblin@tucsonaz.gov.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
06/17/2021 SBEASLE1 COT NON-DSD TRAFFIC Reqs Change Email from: David.Stiffey@TucsonAz.gov
To: CDRC
Thu 6/17/2021 6:15 AM

DP21-0120 Comments,

On sheet 2, the curb returns are drawn in as New. Are the curb returns in fact going to be "New?" Or are the existing returns intended to be utilized?

David Stiffey
06/21/2021 AWARNER1 LANDSCAPE REVIEW Reqs Change CDRC TRANSMITTAL
TO: Planning and Development Services Department, Plans Coordination
FROM: Anne Warner, PLA
PDSD Landscape/Native Plant Preservation Section

PROJECT: Kadampa Meditation Center
ACTIVITY NO: DP21-0120
Address: 5326 E Pima St
Parcel: 121-12-401A
Zoning: C-1
Existing Use: Religious
Proposed Use: Religious & Multi-Family

TRANSMITTAL DATE: June 21, 2021
DUE DATE: June 16, 2021
COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Landscape Review Section comments were addressed.
This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape and water harvesting.
1. UDC 2-10.4.1 Identification and Descriptive Data
A. All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.

The development package will contain the following identification in the lower right corner of each sheet:

Any relevant case numbers for reviews or modifications that affect the site.
Provide Case # on each sheet.

Ensure that Zoning and Engineering comments are addressed prior to landscape section approval.

2. UDC Article 7.6 Landscaping and Screening - The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10. Show required landscape borders, parking area tree requirements and calculations or apply for a Design Development Option, UDC 3.11.1, for relief from the requirement.

All existing landscape to be shown to scale and described, including existing irrigation system. New mesquite symbol is too small.

3. UDC Technical Standards Manual – Section 4-01.0.0. Commercial Rainwater Harvesting and Section 5-01.0.0 Landscaping and Screening.
4. Clearly show curb inlets on both grading and landscape plans to allow runoff to drain into the landscape areas.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package

If you have any questions, please contact me at anne.warner@tucsonaz.gov
06/30/2021 LOREN MAKUS ENGINEERING REVIEW Reqs Change 1. The waste stream calculation shows a weekly volume greater than 190 gallons per week. The minimum volume for the residential use is 135 gallons. Use of roll cans will require permission from Environmental Services and a TSMR.
2. Address the existing wall along the edge of the flowage and water easement. Will the wall be removed, or will it remain?
3. Show slopes on all sidewalks to demonstrate accessibility.
4. Clearly sign the turn-around for no parking. The aerial photos of the site show the area used for parking.
07/01/2021 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Email from: COTDSDPermits
To: Jeff Stanley
Thu 7/1/2021 8:59 AM

Returned for Corrections Notice
DP21-0120

DESCRIPTION: Site/Grading: Kadampa Meditation Center, addition of a triplex to an existing development. 5326 E PIMA ST

FEES DUE: $ 873.40
Please pay at a minimum, the REVIEW Fees. A payment is required before your next submittal. Thank you.

ONLINE PAYMENT
If amount isn't correct, check back in a few hours after it is updated.
https://www.tucsonaz.gov/pdsd/fees
1- Click on: Pay Planning & Permit Fees
2- Enter your Permit Nbr, example: dp20-0000
(not case-sensitive but a hyphen-dash- is needed)
3- Business/Individual Name: Leave this field blank
4- Click "Continue"
5- Pay column - check the boxes
6- Click "Continue"

INCLUDE IN YOUR RESUBMITTAL
1) Comment Response Letter
(your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

Please title your 2nd submittal documents according to this example: 2_Comment Response Letter, 07.01.21

FILEDROP
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
(Select "Existing Application", then enter your permit number)

SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab and you will see different sections
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW


Sharon Beasley, Permit Specialist

City of Tucson, Planning and Development Services
Email for Development Pkgs: COTDSDpermits@TucsonAz.gov
(disregard the email response that will be sent automatically)
Email for Building Permits: PDSDinquiries@TucsonAz.gov