| 05/05/2021 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 05/06/2021 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 05/17/2021 | JPEELDA1 | FIRE | REVIEW | Approved | |
| 06/01/2021 | STEVE SHIELDS | ZONING | REVIEW | Approv-Cond | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: CSM Martin “Gunny” Barreras Memorial Park Renovations Development Package (1st Review) DP21-0109 TRANSMITTAL DATE: June 1, 2021 DUE DATE: May 25, 2021 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is May 04, 2021. The Zoning Review Section conditionally approves the development package for this project subject to the following comments. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development package to verify that those changes do not affect any zoning requirements. 1. COMMENT: 2-06.2.4 – The structures, i.e. shade sails, ramadas, etc. and the electrical plans require a separate submittal to building codes for rewiew. CONTENT REQUIREMENTS 2. COMMENT: 2-06.4.3 – Provide the development package case number, DP21-0109, adjacent to the title block on all sheets. If you have any questions about this transmittal, please contact Elisa Hamblin or Elisa.Hamblin@tucsonaz.gov. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 06/04/2021 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 06/09/2021 | AWARNER1 | LANDSCAPE | REVIEW | Approved | |
| 06/14/2021 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Approved | Email sent from: COTDSDPermits To: Scott Martinez cc: Howard Dutt Mon 6/14/2021 9:57 AM PLAN APPROVAL NOTICE / Request for 4 documents PERMIT/ACTIVITY: DP21-0109 DESCRIPTION: Site/Grading/Swppp - CSM Gunny Barreras Memorial Park, renovations and improvements. 5811 S DEL MORAL BL FEE BALANCE: $0 (zero) Thank you for the payment. NEXT STEPS Please email the following document(s) to: COTDSDpermits@TucsonAZ.gov (Disregard the automatic email response that will be sent) 1. City of Tucson Permit - Check-marked and signed. See attached. 2. Letter of Intent from the Contractor: Includes the project title, project address, Activity Number, AZ ROC number with CR-2 or A-5 grading license classification. https://roc.az.gov/contractor-search 3. Fugitive Dust Activity Permit from Pima County DEQ at (520) 724-7400, http://webcms.pima.gov/cms/one.aspx?pageId=54362 4.Updated Development Package - Add # DP21-0109 to all sheets, adjacent to the title block After we receive the required documentation, please allow a few days for our staff to stamp the approved plans, upload them to PRO (www.tucsonaz.gov/pro), and send you an email notification. That email will include information regarding the approved stamped plans and required inspections. Thank you. Sharon Beasley, Permit Specialist City of Tucson, Planning and Development Services Dept. Email for Development Pkgs: COTDSDpermits@TucsonAz.gov (disregard the email response that will be sent automatically) Email for Building Permits: PDSDinquiries@TucsonAz.gov |