Permit Review Detail
Review Status: Completed
Review Details: GRADING
Permit Number - DP21-0106
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/27/2021 | SBLOOD1 | ENGINEERING | REVIEW | Reqs Change | 1. Show 100-yr water surface elevation lines in the wash. 2. Show that the grades on the pad are 1' higher than the 100-yr WSEL. 3. Show the construction details for the proposed driveway and paving. 4. Show cut/fill quantities to a minimum of what was show on the approved T06BU00190 plans. 5. Show a cross section of site including the protected cut. 6. Show the grading limits per NPPO Plan as shown on T06BU00190. 7. Show a scale and contour interval 8. Provide a legend for line type and hatching or both proposed and existing lines/hatches. 9. Add grading notes including but not limited to: a. Dust control shall be provided by use of a water truck or other approved method. b. All grading shall conform to Technical Standard 2-01. c. A copy of this plan shall be kept in an easily accessible location on the site at all times during construction. d. Geotechnical engineering inspection is required prior to final grading inspection if any approved cut slopes steeper than 2:1 (H:V) are constructed. Special inspection by geotechnical engineer is required for 1:1 (H:V) slopes, or any slopes steeper than 2:1 (H:V). Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
| 04/29/2021 | ELISA HAMBLIN | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL FROM: Elisa Hamblin, AICP PROJECT: Ashford’s Residence, 3172 W SALVIA DR Development Package (1st Review), DP21-0106 TRANSMITTAL DATE: April 29, 2021 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is April 19, 2022. 1. 2-06.3.8 - The north arrow, contour interval, and scale as applicable to each sheet should be placed together in the upper right corner of each sheet. 2. 2-06.3.10 - A legend that shows and describes all symbols used on the drawing is to be provided, preferably on the first sheet. 3. 2-06.4.1 - The name, mailing and email addresses, and phone number of the primary property owner of the site, the developer of the project, registrant(s), and other person(s), firm(s), or organization(s) that prepared the development package documents shall be provided on the right half of the cover sheet. The applicable registration or license number shall be provided if prepared by or with the assistance of a registered professional, such as a surveyor, architect, landscape architect, or engineer. All sealing shall be consistent with Arizona Board of Technical Registration guidelines. 4. 2-06.4.2 – A title block shall be provided in the lower right quadrant of each sheet. The title block shall include the following information and be provided on each sheet: a. 2-06.4.2.A - The proposed name of the project or subdivision, or if there is no name, the proposed tenant's name; b. 2-06.4.2.B - A brief legal description and a statement as to whether the project is a resubdivision are to be provided. On resubdivisions, provide the recording information of the existing subdivision plat; c. 2-06.4.2.D - The page number and the total number of pages in the package (i.e., sheet xx of xx). 5. 2-06.4.3 - The administrative street address and relevant case numbers (development package document, subdivision, rezoning, board of adjustment, DDO, MDR, DSMR, overlay, etc.) shall be provided adjacent to the title block on each sheet. Provide development package case number DP21-0106. 6. 2-06.4.4 - A small, project-location map shall be provided in the upper right corner of the cover sheet. The project-location map to be located on the first sheet of the development package in the upper right corner, shall cover approximately one square mile, be drawn at a minimum scale of three inch equals one mile, and provide the following information. a. 2-06.4.4.A - Show the subject property approximately centered within the one square mile area; b. 2-06.4.4.B - Identify major streets and regional watercourses within the square mile area and all streets that abut the subject property; and, c. 2-06.4.4.C - Section, township, and range; section corners; north arrow; and the scale will be labeled. 7. 2-06.4.7.A.1 - List as a general note: "Existing zoning is RX-2." 8. 2-06.4.7.A.2 - List as a general note the gross area of the site/subdivision by square footage and acreage. 9. 2-06.4.7.A.6 – Add a general note that the site is subject to the Environmental Resource Zone and Hillside Development Zone and that this project is designed to comply with the conditions and standards of those zones. 10. 2-06.4.7.A.6.a - List additional applications and overlays, by case number (if applicable), in lower right corner of each sheet. As a general note provide the type of application processed or overlays applicable, a statement that the project meets the criteria/conditions of the additional application or overlay, the case number, date of approval, what was approved, and the conditions of approval, if any. 11. 2-06.4.8.B – Verify all existing easements are drawn on the plan. The recordation information, location, width, and purpose of all easements on site will be stated. Blanket easements should be listed in the notes, together with recordation data and their proposed status. Should an easement not be in use and be proposed for vacation or have been abandoned, so indicate. However, should the easement be in conflict with any proposed building location, vacation of the easement shall occur prior to approval of plan unless written permission from easement holder(s) is provided. 12. 2-06.4.9.D - Delineate proposed Natural Undisturbed Open Space (NUOS) in a surveyable manner. 13. 2-06.4.9.L - All proposed easements (utility, sewer, drainage, access, etc.) are to be dimensioned and labeled as to their purposes and whether they will be public or private. The easements may have to be recorded and the recordation information added to the development package prior to approval. 14. Address all Engineering review comments. If you have any questions about this transmittal, please contact me at Elisa.Hamblin@tucsonaz.gov. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package (grading plan). |
| 04/29/2021 | AWARNER1 | NPPO | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Planning and Development Services Department, Plans Coordination FROM: Anne Warner, RLA PDSD Landscape/Native Plant Preservation Ordinance Review Section PROJECT: Development Package, Grading Plan, Ashford Residence, 3172 W Salvia Dr (1st Review) DP21-0106 TRANSMITTAL DATE: April 29, 2021 DUE DATE: April 2, 2021 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all NPPO Review Section comments were addressed. This plan has been reviewed for compliance with applicable development criteria in the Unified Development Code (UDC) Administrative Manual (AM) Section 2-11, City of Tucson Uniform Development Code (UDC) Article 7.7 Native Plant Preservation, and the UDC Technical Standards Manual (TSM). 1. A Native Plant Preservation Plan is required for this project in accordance with the requirements of the UDC 7.7.4 General Provisions and Standards and Administrative Manual Section 2-11.4.0. 2. If the site does not contain, or the proposed project does not impact, Protected Native Plants, a request for an exception from the Native Plant Preservation requirements in accordance with Sections 7.7.3.D.3 and .4 of the UDC, can be made. The request for an exception to the Native Plant Preservation must be submitted and processed, as described in Section 2-11.3.0 of the Administrative Manual of the UDC. |
| 04/30/2021 | SBEASLE1 | ZONING-DECISION LETTER | WRITE DECISION LETTER | Reqs Change | Email sent from: COTDSDPermits To: She Ray Fri 4/30/2021 8:11 AM Returned for Corrections PERMIT/ACTIVITY: DP21-0106 DESCRIPTION: GRADING - Ashfords residence, new SFR. 3172 W SALVIA DR FEES DUE: $ 1,038.40 Please pay at a minimum, the REVIEW Fees. A payment is required before your next submittal. Thank you. ONLINE PAYMENT If amount isn't correct, check back in a few hours after data is updated. https://www.tucsonaz.gov/pdsd/fees 1- Click on: Pay Planning & Permit Fees 2- Enter your Permit Nbr, example: dp20-0000 (not case-sensitive but a hyphen-dash- is needed) 3- Business/Individual Name: Leave blank 4- Click Continue 5- Pay column - check the boxes 6- Click Continue INCLUDE IN YOUR RESUBMITTAL 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Plan Set (all pages, full set, even if no changes were made) 3) Any other documents requested by review staff Please title your 2nd submittal documents according to this example: 2_Comment Response Letter, 01.01.21 FILEDROP https://docs.tucsonaz.gov/Forms/tucsonpermitapp (Select "Existing Application", then the permit number) SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab - Reviews - click on Review Details - Documents - click on View to the right of each document Sharon Beasley, Permit Specialist City of Tucson, Planning and Development Services email: COTDSDPermits@TucsonAz.gov (Disregard any automatic reply you might receive) |