Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP21-0082
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/06/2021 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 09/22/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | FROM: Development Services Department Zoning Review PROJECT: Mobeen Shell – Storage Contain Additions Development Package (2nd Review) DP21-0082 TRANSMITTAL DATE: September 22, 2021 DUE DATE: October 04, 2021 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is April 06, 2022. 2-06.3.0 FORMAT REQUIREMENTS 1. This comment was not addressed. COMMENT: 2-06.3.7 – The provided location map is for a project near the corner of Grant & Country Club not for this location. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 2. This comment was not fully addressed. The detail referenced “HANDICAP PARKING ONLY SIGN DETAIL 3/SHT.1. Detail 3 sheet 1 is for a bike rack, provide a detail for the sign. COMMENT: 2-06.4.9.H.5.a – Provide a fully dimensioned detail for a standard vehicle parking space and for the required van accessible vehicle parking space or fully dimension the vehicle use area on the plan. 3. COMMENT: 2-06.4.9.H.5.a – The two (2) standard vehicle parking spaces shown at the northwest corner of the site do not meet the minimum Space Width, see UDC Figure 7.4.6-A and Table 7.4.6-1. 4. This comment was not fully addressed. Demonstrate how the requirements of UDC Article 7.4.9.B.1.e are met. Also revise the bicycle parking space calculation to show the short-term requirements. COMMENT: 2-06.4.9.H.5.d – Based on the addition of the two storage containers two (2) short – term bicycle parking spaces are required. Show the required bicycle parking on the plan along with a detail that demonstrates compliance with UDC Articles 7.4.9.B & .C. For your information based on UDC Article 7.4.8.B1.a.(1) no long – term bicycle parking is required for this site. 5. The street perimeter yard setback shown, 20’-0” is not correct. Per Table 6.4.5.C-1 the required street perimeter yard setback is 21’ or the height of the exterior wall, greater of the two, measured to the back of future curb. COMMENT: 2-06.4.9.O – Provide a street perimeter yard setback from the southern most storage container to the back of future curb, see UDC Article 6.4.5.C.2 & Table 6.4.5.C-1. If you have any questions about this transmittal, please contact Elisa Hamblin or Elisa.Hamblin@tucsonaz.gov. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 10/19/2021 | SBLOOD1 | ENGINEERING | REVIEW | Approved | |
| 10/21/2021 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | Email from: COTDSDPermits To: Alex Enoch Thu 10/21/2021 9:38 AM Returned for Corrections: DP21-0082 DESCRIPTION: SITE - Mobeen Shell, two storage containers. 3601 N ORACLE RD FEES DUE: $ 511.50 Please pay at a minimum, the REVIEW category fees. A payment is required before your next submittal. ONLINE PAYMENT If amount doesn't match "Fees Due", check back in a few hours https://www.tucsonaz.gov/pdsd/fees 1- Click on: Pay Planning & Permit Fees 2- Enter Permit Nbr, example: dp20-0000 (not case-sensitive but a hyphen-dash- is needed) 3- Business/Individual Name: Leave this field blank 4- "Continue" 5- In the Pay column - check the boxes 6- "Continue" REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab and you will see different sections - Reviews section - click on REVIEW DETAILS - Documents section - click on VIEW INCLUDE IN RESUBMITTAL 1) Comment Response Letter (your response to any Requires Change comments) 2) Plan Set (all pages, full set, even if no changes were made) 3) Any other documents requested by review staff Please title your THIRD submittal documents according to this example: 3_Comment Response Letter FILEDROP for Resubmittal https://docs.tucsonaz.gov/Forms/tucsonpermitapp - Select "Existing Application" - In the "Permit Number" field, enter the number and, if applicable, any notes for our staff Thank you. Sharon Beasley, Permit Specialist City of Tucson, Planning and Development Services Email for Development Pkgs: COTDSDpermits@TucsonAz.gov (disregard the email response that will be sent automatically) |