Permit Number: DP21-0081
Parcel: 140411260

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP21-0081
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/07/2021 SBEASLE1 START PLANS SUBMITTED Completed
04/14/2021 JVINCEN1 FIRE REVIEW Reqs Change Building will most probably have fire dept. standpipes. Verify with sprinkler designer. If standpipes are installed, additional fire hydrant will be required within 100' of the connections.
IFC 507.5.1.1 2018

John Vincent
520-349-5581
john.vincent@tucsonaz.gov
04/27/2021 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Two new 1-1/2” backflow preventers are shown for the new building (keynote 6, sheet 5 of 14). One of the units is shown with only a short section of water service pipe; what is the pipe serving and where is it headed? Reference: Section 107.2.1, IBC 2018.
2. The minimum slope for a 3” to 6” building sewer is 1/8” per foot. An 8” building sewer can have a slope of 1/16” per foot (approximately 0.5%) but an 8” building sewer requires manholes instead of cleanouts. The first manhole shall be located within 200 feet of the junction of the building drain and the building sewer. Subsequent manholes shall be spaced not more than 400 feet apart and at each change in direction. Reference: Sections 704.1 and 708.3.2, IPC 2018.
3. Keynote 13, sheet 5 of 14, calls for connecting a 4” building sewer to a 6” private sewer collection system per PCRWRD standard detail 401. That detail calls for the connection to be either directional fittings or a saddle-type tap. The use of saddle-type fittings to connect to a private sewer is prohibited. Reference: Section 707.1 (6), IPC 2018.
4. Provide cleanouts in the building sewer at intervals not exceeding 100 feet of developed pipe length from the upstream entrance of the cleanout. Reference Section 708.1.2, IPC 2018.
05/04/2021 STEVE SHIELDS ZONING REVIEW Reqs Change FROM: Development Services Department Zoning Review

PROJECT: 6601 S Palo Verde Rd – General Manufacturing
Development Package (1st Review)
DP21-0081

TRANSMITTAL DATE: April 5, 2020

DUE DATE: April 5, 2020

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is April 06, 2022.

CONTENT REQUIREMENTS

1. COMMENT: 2-06.4.3 – Provide the development package case number, DP21-0081, adjacent to the title block on all sheets.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

2. COMMENT: 2-06.4.9.H.5.a – Provide a wheel stop location dimension on the ‘TYPICAL PARKING DETAIL” sheet 6, see UDC Article 7.4.6.H.3.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
05/07/2021 LOREN MAKUS ENGINEERING REVIEW Reqs Change 1. Update the SWPPP with the current construction general permit. Make sure the SWPPP conforms to the current CGP.
2. Provide a sidewalk along the south side of the building adjacent to the PAAL. TS 7-01.4.1.B The previously approved site plan show sidewalk along the south side of the existing building.
3. Show roof drainage patterns. Ensure primary roof drains are not directed over sidewalks.
05/11/2021 SBEASLE1 PIMA COUNTY - ADDRESSING PIMA COUNTY - ADDRESSING Needs Review NOTE: Review will begin after invoice from Pima County Addressing is paid. Below is a copy of their email with info:

Email from: Nicholas Jordan <Addressing@pima.gov>
To: City of Tucson, CDRC
Tue 5/11/2021 12:24 PM

The project still has a balance due of $259.
Thank you

Nicholas Jordan, Addressing Specialist

Pima County Development Services Department
201 N Stone AV – 1st Floor
Tucson, AZ 85701
(520) 724-9623
05/28/2021 AWARNER1 LANDSCAPE REVIEW Reqs Change CDRC TRANSMITTAL

TO: Planning and Development Services Department, Plans Coordination

FROM: Anne Warner, RLA
PDSD Landscape/Native Plant Preservation Section

PROJECT: DP21-0081
Address: 6601 S Palo Verde Rd
Parcel: 140-41-1260
Zoning: I-1
Existing Use: Undisturbed Sonoran Desert
Proposed Use: General Manufacturing

TRANSMITTAL DATE: May 28, 2021
DUE DATE: May 4, 2021
COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Landscape Review Section comments were addressed.
This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section 5.
1. UDC 2-10.4.1 Identification and Descriptive Data
A. All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.

2. Please ensure that all related case numbers and this DP number are on all plans.


3. If referring to civil plans, please put the appropriate sheet number next to the reference.

4. Show and dimension existing and future right of way (120’) for Palo Verde.

5. Add plant and irrigation maintenance schedule to plans, per UDC Administrative Manual 2-10-4.4.

a. Pruning schedules to show that plant material will maintain pedestrian and vehicular clearances or that the material will establish opaque hedge screens, if required;
b. Replacement criteria, should plant material not survive; (already on plan)
c. Replacement or upkeep maintenance schedules for inert ground cover materials;
d. Upkeep maintenance schedules for exterior hardscape materials; and,
e. Maintenance and replacement schedules for irrigation systems.

6. Please label landscape border width on all plans. AM Section 2-10-4.2.A.2.f. & .g

7. On landscape border requirement chart, please add the zoning to the “No landscape border required”.

8. What is meant by “riparian limit”? If there is no existing riparian area please remove hatch and labels.

9. Show point of drainage off roof areas, amount of flow, and disposition of flow.

10. Detail the temporary system proposed to establish native seeded areas.

11. Show nursery holding area on plans.

12. According to parking calculations 21 trees are required, but 15 trees are provided in the new parking area, please add 6 trees to the parking area. The trees in the area north of the parking lot will not count towards this requirement.

13. Modify construction details for trees and shrubs to mirror the water harvesting shown on Detail 8.

14. Provide a detail to show tree planting with root barrier adjacent to walkways.

15. Show and label parking canopy.


RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package

If you have any questions, please contact me at anne.warner@tucsonaz.gov or (520) 837-4969.
05/31/2021 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Email sent from: COTDSDPermits
To: Theresa Hadley
Mon 5/31/2021 9:28 AM

Returned for Corrections Notice
PERMIT/ACTIVITY: DP21-0081

DESCRIPTION: Site/Grading/Swppp - Tucson Container Corporation. New warehouse building. 6601 S PALO VERDE RD

FEES DUE: $ 4,349.94
Please pay at a minimum, the REVIEW Fees. A payment is required before your next submittal. Thank you.
ONLINE PAYMENT
If amount isn't correct, check back in a few hours after it is updated.
https://www.tucsonaz.gov/pdsd/fees
1- Click on: Pay Planning & Permit Fees
2- Enter your Permit Nbr, example: dp20-0000
(not case-sensitive but a hyphen-dash- is needed)
3- Business/Individual Name: Leave blank
4- Click "Continue"
5- Pay column - check the boxes
6- Click "Continue"

INCLUDE IN YOUR RESUBMITTAL
1) Comment Response Letter
(your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

Please title your 2nd submittal documents according to this example: 2_Comment Response Letter, 01.01.21

FILEDROP
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
(Select "Existing Application", then enter the permit number)

SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews - click on REVIEW DETAILS
- Documents - click on VIEW


Sharon Beasley, Permit Specialist

City of Tucson, Planning and Development Services
Email for Development Pkgs: COTDSDpermits@TucsonAz.gov
(disregard the email response that will be sent automatically)
Email for Building Permits: PDSDinquiries@TucsonAz.gov