Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: DP21-0073
Parcel: 14044009D

Address:
7720 S WILMOT RD

Review Status: Completed

Review Details: TENTATIVE PLAT REVIEW

Permit Number - DP21-0073
Review Name: TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/02/2022 SBEASLE1 ZONING-DECISION LETTER REVIEW Approved DATE: November 29, 2021

TO: John Beall FROM: Samuel Rogers
Entitlements Section Manager Planner

SUBJECT: Rezoning for (DP21-0073) Black Hawk Ranch an FLD Subdivision Lots 1 thru 310 based on Development Package of (C9-21-01) Blackhawk - Wilmot & I-10

The above referenced development package has been conditionally-approved by the City Development Review Committee (CDRC) to prepare the rezoning ordinance for Mayor & Council adoption. The ordinance may be scheduled for Mayor & Council adoption at any time.

Conditions of the rezoning per the decision of the Mayor & Council are hereby met on the Development Package.

No permits or development approvals [which includes excavation, grubbing, grading, paving] may be granted that are in furtherance of the rezoning request until the 30 days have lapsed and the conditions of rezoning have been met per UDC 3.5.3.J.6.

The applicant is responsible for notifying Samuel Rogers, Planner, at (520) 837-6932 or Samuel.Rogers@tucsonaz.gov when the 30 days near. At that time, staff will review the ordinance adopted by Mayor & Council and the applicant will receive an approval notification to obtain the permit for the development package.


Attachment: Development Package

xc: Project Record by Activity Number

cc: Linda Thompson, The WLB Group Inc.
03/02/2022 SBEASLE1 ZONING-DECISION LETTER REVIEW Approved Email from: COTDSDPermits
To: Linda Thompson
cc: D. Little
Wed 3/2/2022 10:02 AM

PLAN APPROVAL NOTICE / Request for 3 documents
Development Package PERMIT/ACTIVITY: DP21-0073

DESCRIPTION: Tentative Plat/FLD - Blackhawk Ranch, Lots 1 thru 310, Block One, Common Areas "A" (natural open space), "B" (landscape, drainage, slope and maintenance, access), and "C" (functional open space, recreation).
7720 S WILMOT RD

FEE BALANCE: $0 (zero) Thank you for the payment.

YOUR NEXT STEPS
Please reply to this email and attach:
1. City of Tucson Permit - Check-marked and signed. See attached.
2. Letter of Intent from the Contractor: Includes the project title, project address, Activity Number, and Arizona ROC number with CR-2 or A-5 grading license classification. https://roc.az.gov/contractor-search
3. (Area of Disturbance is over one acre) Fugitive Dust Activity Permit from Pima County DEQ at (520) 724-7400, http://webcms.pima.gov/cms/one.aspx?pageId=54362

After all the requirements are met, please allow a few days for our staff to stamp the approved plans, upload them to PRO (www.tucsonaz.gov/pro), and send you a "Plan Issued" email. That email will include information regarding the approved stamped plans and required inspections.

Thank you.
Sharon Beasley, Building Permit Specialist

City of Tucson, Planning and Development Services Dept.
Email: COTDSDpermits@TucsonAz.gov
11/02/2021 SBEASLE1 START PLANS SUBMITTED Completed
11/03/2021 SBEASLE1 UTILITIES TUCSON ELECTRIC POWER Approved email from: TEP-DEVREV <TEPDEVREV@tep.com>
To: CDRC
Tue 11/2/2021 2:37 PM

Tucson Electric Power Co., (TEP) has reviewed and approves the Tentative plat for Blackhawk subdivision. Costs for removal or relocation of existing TEP facilities will be billable to the developer. A Preliminary electrical design is in process. A Construction drawing will be prepared after customer approval of the Preliminary design and receipt of the Approved Tentative Plat.
If there are any questions, please contact Courtney Tejeda at 520-820-9154.
11/08/2021 JPEELDA1 FIRE REVIEW Approved
11/09/2021 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Approved Email from: Jay Gomes <jgomes@azdot.gov>
To: CDRC
Tue 11/9/2021 12:36 PM

The access point to the Frontage Road between Craycroft and Wilmot has been removed since there will be a new connection of Los Reales/Garden Stone to Craycroft.
The TIA has been updated to reflect the changes and is acceptable since ADOT impacts are diminished.
The Developer has added the Right-in / Right-out connection to Wilmot to their off-site improvement plans, so as to push ultimate improvement to Wilmot Road into the future for the City of Tucson.

ADOT has no further comments.
We appreciate the opportunity to review this development.

Jay Gomes
Arizona Dept. of Transportation
11/09/2021 STEVE SHIELDS ZONING REVIEW Approved
11/29/2021 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed 11/29/21 - Engineer removed BWV for lot 196, OK to approve.

11/18/21 - Lot 196 is still incorrectly identified as needing a backwater valve. Where the finish floor elevation is less than 12 inches above the elevation of the next upstream manhole cover in the sewer, a backwater valve shall be installed The FFE of lot 196 is exactly 12" above the rim elevation of the next upstream manhole. [Second comment: Based on the revised drawings, the following lots will require backwater valves but are not so identified: 23, 26, 27, 28, 29, 30, 31, 32, 80, 81, 82, 83, 84, 85, 86, 87, 89, and 90. Lot 196 is incorrectly identified as needing a backwater valve.] [Initial comment: Provide the first-floor elevations of the proposed buildings. Determine the need for a backwater valve per Section 714.1, IPC 2018, as amended by the City of Tucson. Reference: City of Tucson Administrative Manual, Section 2-06.4.8D and Section 107.2.1, IBC 2018.]