Permit Number: DP21-0065
Parcel: 30503005C

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP21-0065
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/24/2021 SBEASLE1 START PLANS SUBMITTED Completed
07/14/2021 SBEASLE1 OTHER AGENCIES TUCSON AIRPORT AUTHORITY Approved July 14, 2021

RE: DP21-0065 /Site/Grading/SWPPP - Tucson Police Department, 2nd submittal, Received
June 24, 2021

Thank you for the opportunity to comment on DP21-0065 /Site/Grading/SWPPP – Tucson Police Department; 2nd Submittal, a development package application for a 14.3 acre site, located east of South Wilmot Road and south of the existing City of Tucson Policy Academy.

The property is zoned Rural Homestead Zone (RH), with the proposed use being protective
services for the storage of vehicles and the processing of evidence.

This site is within the Tucson International Airport avigation easement requirements and public disclosure area, FAA traffic pattern airspace, and FAA Part 77 airspace.

The Tucson Airport Authority is satisfied with the 2nd submittal of this project and has no additional comments to provide.

Please do not hesitate to contact me if you have any questions or concerns regarding this comment letter. I can be reached by email at srobidoux@flytucson.com or by telephone at 520-573-4811.
Respectfully,
Scott Robidoux, C.M., Senior Airport Planner
07/22/2021 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Development Services Department Zoning Review

PROJECT:
Development Package (2nd Review)
DP21-0065

TRANSMITTAL DATE: July 22, 2021

DUE DATE: July 20, 2021

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is March 30, 2022.

Previous Comment 9. This comment was not addressed correctly. Per UDC Table 7.4.8-1: Minimum Required Bicycle Parking Spaces, Civic Use Group, Short-term requirement is 1 space per 8,000 sq ft. GFA, minimum 2 and Long-term requirement is 1 space per 12,000 sq ft GFA, minimum 2. Revise the bicycle parking space calculation to reflect the correct numbers. Detail 16 sheet C602 meets the requirement for the Long-term bicycle parking but does not meet the requirements of the Short-term. Per UDC Article 7.4.9.C.2.b the Short-term bicycle parking shall be located outside the building. Show the required outdoor Short-term location on the plan and provide a short-term bicycle parking space detail that demonstrates that all requirement listed under UDC Articles 7.4.9.B.1 & .2 and 7.4.9.C are met. 2-06.4.9.H.5.d - Show bicycle parking facilities fully dimensioned. For specifics, refer to Section 7.4.9, Bicycle Parking Design Criteria, of the UDC. Provide, as a note, calculations for short and long term bicycle spaces required and provided. Bike parking within the Civic Use Group is required at 1 space per 8,000 sq ft. GFA short term, and 1 space per 12,000 sq ft GFA long term.

Previous Comment 12. This comment was not fully addressed. Per TSM Section 7-01.4.1.A At least one sidewalk is required to a project from each street on which the project has frontage, unless there is no vehicular access from a street because of a physical barrier, such as a drainageway or an unbroken security barrier (e.g., a wall or fence). Show the required sidewalk from the propose building to Wilmot Rd. At a minimum Zoning recommends that you provide a 4’-0” wide pave and striped area along the proposed access lane. A Technical Standards Modification Request (TSMR) will need to be submitted and approved for a substitute surface for the sidewalk, see TSM Section 1-01.6.0 for TSMR requirements. The application can be found at: https://www.tucsonaz.gov/files/pdsd/forms/Modification_Request_Application_for_Parking_Design_PDMR_or_Technical_Standard_TSMR.pdf. 2-06.4.9.R - Show on-site pedestrian circulation and the design criteria in Section 7-01.0.0, Pedestrian Access, of the Technical Standards Manual.

Once the above comments are addressed and the DP has been resubmitted contact Elisha Hamblin and request an expedited review.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
07/22/2021 SBLOOD1 ENGINEERING REVIEW Reqs Change 1. The entrance driveway paving needs to have a barrier on both sides of the lane to contain the 10" of ac millings. Please revise plans to show 6" vertical curb on both sides of the lane.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
07/22/2021 SSHIELD1 LANDSCAPE REVIEW Approved
07/23/2021 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Email from: COTDSDPermits
To: E. OBrien, Terry Gilliland
Fri 7/23/2021 9:42 AM

Returned for Corrections DP21-0065
DESCRIPTION: Site/Grading/Swppp - Tucson Police Department. New evidentiary processing/storage building and associated vehicle storage yard. 10505 S WILMOT RD
FEE BALANCE: $0 (zero) Thank you for the payment.

INCLUDE IN YOUR RESUBMITTAL
1) Comment Response Letter
(your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

Please title your 3rd submittal documents according to this example: 3_Comment Response Letter, 07.01.21

FILEDROP
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
(Select "Existing Application", then enter permit number)

SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab and you will see different sections
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

Thank you.

Sharon Beasley, Permit Specialist

City of Tucson, Planning and Development Services
Email for Development Pkgs: COTDSDpermits@TucsonAz.gov
(disregard the email response that will be sent automatically)
Email for Building Permits: PDSDinquiries@TucsonAz.gov