Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: TENTATIVE PLAT REVIEW
Permit Number - DP21-0060
Review Name: TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/21/2021 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 05/25/2021 | SBLOOD1 | ENGINEERING | REVIEW | Approved | |
| 06/08/2021 | SBEASLE1 | PIMA COUNTY | ADDRESSING | Reqs Change | (The ATTACHED PDF mentioned below can be viewed online: www.TucsonAz.gov/Pro. See the Documents section.) Email from: Robin Freiman <Addressing@pima.gov> To: CDRC Fri 6/4/2021 2:44 PM Bella Tierra, tentative plat, 2nd submittal review, DP21-0060 is being Returned for Corrections by Pima County Addressing. The attached pdf contains Addressing’s comments. Please let me know if you have any questions. Thank you, Robin Freiman, Addressing Official Pima County Development Services Department 201 N Stone AV – st Floor Tucson, AZ 85701 (520) 724-7570 |
| 06/09/2021 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | Assuming a FFE that is 8-inches higher than the pad elevation, my calculations indicate that, in addition to the lots you identified, lots 23, 43, 46, 47, 62, and 63 require backwater valves. [Initial comment: Revise the site drawing to indicate for which lots backwater valves will be required because the rim elevation of the next upstream sanitary manhole is less than 12” below the proposed first floor elevations. Reference: Section 714.1, IPC 2018, as amended by the City of Tucson.] |
| 06/16/2021 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 06/21/2021 | AWARNER1 | LANDSCAPE | REVIEW | Approved | |
| 06/25/2021 | ALEXANDRA HINES | DESIGN PROFESSIONAL | REVIEW | Approved | Applicant shall submit architectural variation plan (AVP) as revision to this development package by uploading online using DP21-0060 prior to zoning approving building permits. |
| 07/07/2021 | SBEASLE1 | COT NON-DSD | TRAFFIC | Approved | Email from: David.Stiffey@TucsonAz.gov To: CDRC Wed 7/7/2021 10:57 AM My previous comments were adequately addressed. No further comments from Traffic. David Stiffey City of Tucson |
| 07/07/2021 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | Email from: COTDSDPermits To: C Thompson Wed 7/7/2021 12:11 PM Returned for Corrections Notice, DP21-0060 DESCRIPTION: Tentative Plat/FLD - Bella Tierra, Phase 3. An FLD Subdivision, Lots 1-78 and common areas A-1, B-1, B-2, C-1 thru C-4. 4855 S WINGATE BL FEE BALANCE: $0 (zero) Thank you for the payment. INCLUDE IN YOUR RESUBMITTAL 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Plan Set (all pages, full set, even if no changes were made) 3) Any other documents requested by review staff Please title your 3rd submittal documents according to this example: 3_Comment Response Letter, 07.01.21 FILEDROP https://docs.tucsonaz.gov/Forms/tucsonpermitapp (Select "Existing Application", then enter your permit number) SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab and you will see different sections - Reviews section - click on REVIEW DETAILS - Documents section - click on VIEW Sharon Beasley, Permit Specialist City of Tucson, Planning and Development Services Email for Development Pkgs: COTDSDpermits@TucsonAz.gov (disregard the email response that will be sent automatically) Email for Building Permits: PDSDinquiries@TucsonAz.gov |