Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: DP21-0040
Parcel: 121091680

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP21-0040
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/22/2021 SBEASLE1 START PLANS SUBMITTED Completed
05/25/2021 JOHN VAN WINKLE ENGINEERING REVIEW Approved
05/26/2021 SSHIELD1 LANDSCAPE REVIEW Approved
05/26/2021 STEVE SHIELDS ZONING REVIEW Reqs Change FROM: Development Services Department Zoning Review

PROJECT: Tucson Water Well Site B-052B
Development Package (1st Review)
DP21-0040

TRANSMITTAL DATE: March 23, 2021

DUE DATE: March 18, 2021

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is February 18, 2022.


2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

1. This comment was not addressed correctly. The code section shown on the plan is “2.4.3” not 3.4.3 as requested. COMMENT: 2-06.4.7.A.1 – Sheet 3 “ZONING AND LAND USE NOTES, PROPOSED ZONING IS R-1, SPECIAL EXEMPTION” revise “EXEMPTION” to read “[2] Zoning Examiner Special Exception Procedure, Section 3.4.3”

2. This comment was not addressed correctly. The case number should be listed as T21SE00001. COMMENT: 2-06.4.7.A.6.a – Once the Special Exception process is approved provide the T21SE#### adjacent to the title block on all sheets and provided a general note stating the Special Exception case number date of approval, and if applicable any conditions of approval.

2-06.4.7.A.8 - For development package documents provide:

3. The lot coverage calculation is not correct. The lot coverage shall include all buildings and vehicle use area, this includes the drive area that provides access to the parking spaces. The calculation shall be based on the total square footage of all buildings and vehicle use area, not broke out as individual areas. COMMENT: 2-06.4.7.A.8.b – Provide a lot coverage calculation on the plan that meets the requirement of UDC Article 6.4.3. Per UDC TABLE 6.3-2.A: DIMENSIONAL STANDARDS FOR THE R-1, R-2, R-3, MH-1, & MH-2 ZONES, R-1 ZONE, the maximum lot coverage is 70%.

4. COMMENT: 2-06.4.7.A.6.a – The Special Exception conditions have not clearly been addressed on the plans. For the west property line sheet 3 calls out to “REMOVE & REPLACE EXISITNG CHANG LINK FENCE 8’ WALL”, sheet 4 calls out “REMOVE & REPLACE CHAIN LINK FENCE WITH 8’ HT CMU SCREEN WALL”. The plans should be consistent and call out “an 8’ high masonry wall’ per SE condition 5. For the north & south property line the fence note should address the required “tan plastic privacy slats” per SE condition 5.

5. COMMENT: 2-06.4.7.A.6.a – Provide setback dimension from the communications antenna the demonstrate that the requirements of SE condition 8 are met.

If you have any questions about this transmittal, please contact Elisa Hamblin, Elisa.Hamblin@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
05/27/2021 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Email from: COTDSDPermits
To: Dorothy Dolan
Thu 5/27/2021 3:05 PM

Returned for Corrections Notice
PERMIT/ACTIVITY: DP21-0040

DESCRIPTION: Site/Grading - Equip Well B-052B, City of Tucson Water. 1937 N NANCY ROSE BL

FEE BALANCE: $0 (zero) Thank you for the payment.

INCLUDE IN YOUR RESUBMITTAL
1) Comment Response Letter
(your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

Please title your 3rd submittal documents according to this example: 3_Comment Response Letter, 01.01.21

FILEDROP
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
(Select "Existing Application", then enter the permit number)

SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews - click on REVIEW DETAILS
- Documents - click on VIEW


Sharon Beasley, Permit Specialist

City of Tucson, Planning and Development Services
Email for Development Pkgs: COTDSDpermits@TucsonAz.gov
(disregard the email response that will be sent automatically)
Email for Building Permits: PDSDinquiries@TucsonAz.gov