Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: DP21-0039
Parcel: 13213099A

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP21-0039
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/29/2021 SBEASLE1 START PLANS SUBMITTED Completed
05/05/2021 SBLOOD1 ENGINEERING REVIEW Approved
05/06/2021 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. The boxed PCDEQ note on U-1 needs to be revised; PCDEQ approval will be required due to the presence of manholes. [Initial comment: Private sewers 8-inches and larger require manholes, not cleanouts. Reference: Section 708.1.2, IPC 2018.]
2. The rim elevation of the new manhole (MH #2, 2489.00’) upstream of new BCS is less than 12” below the FFE (2489.10’) of the proposed building; a backwater valve will be required. Reference: Section 714.1, IPC 2018.
05/28/2021 STEVE SHIELDS ZONING REVIEW Approved
05/28/2021 SSHIELD1 LANDSCAPE REVIEW Approved
06/01/2021 JOHN BEALL COT NON-DSD COMMUNITY PLANNING Passed
06/02/2021 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Email sent from: COTDSDPermits
To: J Behrana
Wed 6/2/2021 10:32 AM

Returned for Corrections Notice
PERMIT/ACTIVITY: DP21-0039

DESCRIPTION: Site/Grading/Swppp - Orthopros at Tucson Marketplace. A portion of Lot 3 of Tucson Marketplace -
Phase 5. 1402 E TUCSON MARKETPLACE BL

FEE BALANCE: $0 (zero) Thank you for the payment.

INCLUDE IN YOUR RESUBMITTAL
1) Comment Response Letter
(your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

Please title your 3rd submittal documents according to this example: 3_Comment Response Letter, 01.01.21

FILEDROP
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
(Select "Existing Application", then enter the permit number)

SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews - click on REVIEW DETAILS
- Documents - click on VIEW


Sharon Beasley, Permit Specialist

City of Tucson, Planning and Development Services
Email for Development Pkgs: COTDSDpermits@TucsonAz.gov
(disregard the email response that will be sent automatically)
Email for Building Permits: PDSDinquiries@TucsonAz.gov