Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP21-0029
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/25/2021 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 03/31/2021 | JVINCEN1 | COT NON-DSD | FIRE | Approved | |
| 04/13/2021 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 04/16/2021 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Reqs Change | DP21-0029 1) Previous comment 3. The alignment of the pedestrian connection to E Ajo Way differs from that shown in DP20-0189. Update as needed. If a new path is planned, Show that ramp grades do not exceed 12:1 slope. Maximum fall in a ramp is 6" before a handrail is needed, current fall is show to be .55'. Show spot grades outside of property line to ensure ADA compliance 2) Previous Comment 6. Clarification. There is a pedestrian path to the order board that needs to be physically separated from the drive through lane. 3) Previous comment 7. Ensure that roof drains, from the new building and scupper underneath sidewalks as needed. Reference COT Technical Standards Manual (TSM) section 7-01.4.1. e. Show roof drain locations on plans. 4) Previous comments 8 and 9. These comments only pertain to the water harvesting areas constructed as part of this development. Show spot grades in each of the water harvesting areas. 5) Previous comment 11. Several of the water harvesting areas as measured on the plans do not provide the volume stated in the water harvesting plans. Please double check to show that the constructed basins will match the volumes shown in the water harvesting plan. 6) Previous comment 12. Adjust planting plan adjacent to the trash enclosure to provide minimum vertical clearance for service vehicles. Plans still show a Texas mountain laurel overhanging the trash enclosure. Update as needed John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov |
| 04/20/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | FROM: Development Services Department Zoning Review PROJECT: Raising Cane’s – 1-10 & E Ajo Way Development Package (2nd Review) DP21-0029 TRANSMITTAL DATE: April 20, 2021 DUE DATE: April 26, 2021 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is February 01, 2022. CONTENT REQUIREMENTS 1. This comment was not addressed. 2-06.4.1 – Provide the email address for the Architect listed on the cover sheet. 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. 2-06.4.7.A - Zoning and Land Use Notes 2. 2-06.4.7.A.3 – Zoning acknowledges that this comment should have been provided on the first submittal but as other corrections are needed provide the rezoning conditions on the plan.. 3. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 4. This comment was not addressed. Provide the zoning for the parcels north of Ajo and to the southeast of this site. 2-06.4.9.F - All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined. If the property is being rezoned, use those boundaries and classifications. 5. This comment was not addressed. The accessible signs are still shown within the 2’-6” overhang as shown o the detail, but you have a note that shows the signs within a landscape area as either building or pole mounted. Clarify what you are proposing. 2-06.4.9.H.5.a – On the “ACCESSIBLE AND STANDARD PARKING DETAIL” it appears that the proposed accessible parking sign encroaches into the required 2’-6” vehicle overhang. Clearly demonstrate that the 2’-6” overhang is maintained. 6. This comment was not addressed correctly. Your wheel stop dimension shows the wheel stop as 2’-6” from the back of curb to the front of the wheel stop. UDC Article 7.4.6.H.3 & Figure shows the dimension from the face of curb to the back of the wheel stop. 2-06.4.9.H.5.a – On the “PRECAST CONCRETE WHEEL STOP” detail Per UDC Article 7.4.6.H.3 the dimension from the front of the vehicle parking space to the back of the wheel stop should be 2’-6”. If you have any questions about this transmittal, please contact Elisa Hamblin, Elisa.Hamblin@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 04/20/2021 | SSHIELD1 | LANDSCAPE | REVIEW | Approved | |
| 04/26/2021 | SBEASLE1 | OTHER AGENCIES | TUCSON AIRPORT AUTHORITY | Approved | April 26, 2021 RE: DP21-0029 / Site/Grading/Swppp - Raising Cane's restaurant, 2nd submittal review, Received March 25, 2021 Thank you for the opportunity to comment on DP21-0029, Site/Grading/Swppp - Raising Cane's restaurant; 2nd Submittal, a development package application for an approximately 1.47 acre site, located southeast of the intersection of East Ajo Way and South Kino Parkway and is west of the Kino Sports Complex. The property is currently zoned Residence Zone 1 (R-1) but was rezoned during C9-20-07 to Commercial Zone 2 (C-2) to support the future development of a mixture of commercial and retail uses. The proposed project is to establish a new food service use. This site is within the Tucson International Airport avigation easement requirements and public disclosure area, FAA traffic pattern airspace, and FAA Part 77 airspace. The Tucson Airport Authority approves the 2nd submittal of the project and has no additional comments to provide. Please do not hesitate to contact me if you have any questions or concerns regarding this comment letter. I can be reached by email at srobidoux@flytucson.com or by telephone at 520-573-4811. Respectfully, Scott Robidoux, C.M. , Senior Airport Planner |
| 05/14/2021 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | Email sent from: COTDSDPermits To: Erin Harris Fri 5/14/2021 8:38 AM Returned for Corrections Notice PERMIT/ACTIVITY: DP21-0029 DESCRIPTION: Site/Grading/Swppp - Raising Cane's restaurant. 2100 E AJO WY FEES DUE: $ 1,107.50 Please pay at a minimum, the REVIEW Fees. A payment is required before your next submittal. Thank you. ONLINE PAYMENT If amount isn't correct, check back in a few hours after it is updated. https://www.tucsonaz.gov/pdsd/fees 1- Click on: Pay Planning & Permit Fees 2- Enter your Permit Nbr, example: dp20-0000 (not case-sensitive but a hyphen-dash- is needed) 3- Business/Individual Name: Leave blank 4- Click "Continue" 5- Pay column - check the boxes 6- Click "Continue" INCLUDE IN YOUR RESUBMITTAL 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Plan Set (all pages, full set, even if no changes were made) 3) Any other documents requested by review staff Please title your 3rd submittal documents according to this example: 3_Comment Response Letter, 01.01.21 FILEDROP https://docs.tucsonaz.gov/Forms/tucsonpermitapp (Select "Existing Application", then the permit number) SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab - Reviews - click on Review Details - Documents - click on “View” Sharon Beasley, Permit Specialist City of Tucson, Planning and Development Services Email for Development Pkgs: COTDSDpermits@TucsonAz.gov Email for Building Permits: PDSDinquiries@TucsonAz.gov |
| 05/14/2021 | SBEASLE1 | COT NON-DSD | TRAFFIC | Approved | Email from: David.Stiffey@TucsonAz.gov To: CDRC Thu 5/13/2021 8:07 AM Approved. David Stiffey, Program Coordinator City of Tucson Transportation & Mobility |