Permit Review Detail
Review Status: Completed
Review Details: DEV PKG
Permit Number - DP21-0027
Review Name: DEV PKG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/02/2021 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 02/24/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | FROM: Development Services Department Zoning Review PROJECT: Sher-E-Punjab – Outdoor Seating Expansion Development Package (1st Review) DP21-0027 TRANSMITTAL DATE: February 24, 2021 DUE DATE: February 26, 2021 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is February 01, 2022. CONTENT REQUIREMENTS 1. 2-06.4.1 - Provide the name, mailing and email addresses, and phone number of the primary property owner of the site and the developer near the right half of the cover sheet. 2. 2-06.4.3 – Provide the development package case number, DP21-0027, adjacent to the title block on all sheets. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 3. 2-06.4.9.H.5.a – The vehicle parking space calculation is not correct. Under ‘NEW PATIO” you list 1,134 SF/200 PER RETAIL” As you are using the Shopping Center calculation per UDC TABLE 7.4.4-1: MINIMUM NUMBER OF MOTOR VEHICLE SPACES REQUIRED, RETAIL TRADE USE GROUP, Shopping Center is parked at 1 space per 300 sq. ft. GFA. Also the number required should be 300 +4 = 304. 4. 2-06.4.9.Q – On the plan you show “Yamoto’s Patio 900 SF” either provide documents that permitted this patio or remove it from the plan. If you have any questions about this transmittal, please contact Elisa Hamblin, Elisa.Hamblin@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 02/25/2021 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 03/01/2021 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
| 03/02/2021 | MROSS2 | FIRE | REVIEW | Reqs Change | Indicate how far seating area is from existing building roofline. Indicate where patio cover will be located and distance from existing building roof. Michael Ross 520-837-7082 Michael.Ross2@tucsonaz.gov |
| 03/04/2021 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | DATE: March 4, 2021 Returned for Corrections PERMIT/ACTIVITY: DP21-0027 DESCRIPTION: Site - Sher-E-Punjab, new patio, 853 E GRANT RD FEES DUE: $ 429.00 Please pay the total fees (or at a minimum, the REVIEW Fees). A payment is required before your resubmittal. ONLINE PAYMENT https://www.tucsonaz.gov/pdsd/fees If information is not available or amount isn't correct, check back in a few hours after data is updated. (Visa, MC, Discover, American Express, or pay from bank account) 1- Click on: Pay Planning & Permit Fees 2- Enter your Permit Nbr, example: dp20-0000 (not case-sensitive but a hyphen-dash- is needed) 3- Business/Individual Name: Leave blank 4- Click the blue tab: Continue 5- Under the Pay column, check the boxes 6- Click Continue RESUBMITTAL Submit the following documents to: https://docs.tucsonaz.gov/Forms/tucsonpermitapp (Select "Existing Application", then the permit number) 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Plan Set (all pages, full set, even if no changes were made) 3) Any other documents requested by review staff - Title the documents for your 2nd submittal starting with the submittal number, for example: 2_Plan_Set SEE REVIEW COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab - Reviews - click on Review Details - Documents - click on View to the right of each document For all NEW development package submittals on the new Filedrop page, select the box: "SITE REVIEW...". Thank you. City of Tucson Attn: Sharon Beasley, Permit Specialist Planning and Development Services email: COTDSDPermits@TucsonAz.gov |