Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP21-0025
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/05/2021 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 03/19/2021 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Reqs Change | DP21-0025 1) Previous comment 2. Show on plans that proposed new curb access ramps, will be updated to PAG standard 207 and Including the use of detectable warnings, to match surrounding new site conditions. This comment was un-related to work in the right of way. Existing onsite pedestrian paths for other developments utilize detectable warnings 2) Previous comment 4. Provide a detail or dimension showing that the wheel stops for the proposed parking area provide a 2.5' vehicle overhang. Reference Unified Development Code (UDC) figure 7.4.6-C. Update detail shows 3' from back of wheel stop. Dimension should be 2.5' from front of wheel stop 3) Previous comment 5, Provide spot grades for the corners for all curb access ramp paths to show that ADA slopes are being met. Additional provided spot grades are only for the top of the ramp landing area. Provide spot grades at the corners of each ramp. 4) Previous comment 7. Provide A basis of Bearings and elevation according to Administrative Manual Section 2-06.4.8. This comment was not addressed. John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov |
| 04/08/2021 | AWARNER1 | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Planning and Development Services Department, Plans Coordination FROM: Anne Warner, RLA PDSD Zoning Review Section PROJECT: CVS – Exterior ADA improvements, 2601 S. Houghton Road Development Package (2nd Review) DP21-0023 TRANSMITTAL DATE: April 7, 2021 DUE DATE: April 2, 2021 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. The one-year expiration date for this project is February 1, 2021. 2-06.3.0 Content 1. 2-06.4.4 - There are two location maps on the cover sheet, please remove one, and ensure that the other is corrected. Please provide all the following information on one map as described below. 2. 2-06.4.4.A-C Show the subject property approximately centered within the one square mile area. Identify major streets and regional watercourses within the square mile area and all streets that abut the subject property; and label section, township, and range; section corners; north arrow; and the scale. 3. 2-06.4.7.A.4 - The existing and proposed zone is listed, however, the use of the property as classified per the UDC is not. List all UDC sections applicable to the existing use, Retail Land Use, General Merchandise Sales, subject to 4.9.9.B.1. 4. 2-06.4.7.A.8.a – Provide floor area for the building within the building envelope. 5. 2-06.4.8.C - Sheet AS2 – Provide recordation data of adjacent streets. |
| 04/12/2021 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | DATE: April 12, 2021 Returned for Corrections PERMIT/ACTIVITY: DP21-0025 DESCRIPTION: SITE - CVS Pharmacy - 2601 S. Houghton Road, parking lot upgrades. FEE BALANCE: $0 (zero) Thank you for the payment. RESUBMITTAL Submit the following documents to: https://docs.tucsonaz.gov/Forms/tucsonpermitapp (Select "Existing Application", then the permit number) 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Plan Set (all pages, full set, even if no changes were made) 3) Any other documents requested by review staff Title your 3rd submittal documents according to this example: 3_Comment Response Letter, 01.01.21 SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab - Reviews - click on Review Details - Documents - click on View to the right of each document Thank you. Sharon Beasley Permit Specialist City of Tucson, Planning and Development Services email: COTDSDPermits@TucsonAz.gov (Disregard the automatic reply you will receive: "This email account...") |