Permit Number: DP21-0025
Parcel: 136100940

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP21-0025
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/08/2021 SBEASLE1 START PLANS SUBMITTED Completed
02/11/2021 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change DP21-0025
1) Include all standard applicable notes found in the COT Administrative Manual (AM) section 2-06, including but not limited to the hold harmless note in AM 2-06.4.7 and Drainage will remain in its natural state note
2) Show on plans that proposed new curb access ramps, will be updated to PAG standard 207 and Including the use of detectable warnings, to match surrounding new site conditions
3) At the Houghton entrance, update accessible pathway to include diagonal portion of sidewalk
4) Provide a detail or dimension showing that the wheel stops for the proposed parking area provide a 2.5' vehicle overhang. Reference Unified Development Code (UDC) figure 7.4.6-C
5) Provide spot grades for the corners for all curb access ramp paths to show that ADA slopes are being met
6) Detail 4/AS4, show that a minimum 4' width is being provided for keynote 17
7) Provide A basis of Bearings and elevation according to Administrative Manual Section 2-06.4.8

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
02/22/2021 STEVE SHIELDS ZONING REVIEW Reqs Change FROM: Development Services Department Zoning Review

PROJECT: CVS – 3832 E Speedway Blvd – Accessible Parking Upgrades
Development Package (1st Review)
DP20-0023

TRANSMITTAL DATE: February 22, 2021

DUE DATE: February 24, 2021

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is February 1, 2022.

2-06.3.0 FORMAT REQUIREMENTS

1. 2-06.3.12 - An index of sheets in the development package shall be provided on the first sheet.

CONTENT REQUIREMENTS

2. 2-06.4.3 – Provide the development package case number, DP21-0023 , adjacent to the title block on all sheets.

3. 2-06.4.4 - A small, project-location map shall be provided in the upper right corner of the cover sheet. This map shall cover approximately one square mile, be drawn at a minimum scale of three-inch equals one mile, and provide the following information;
Show the subject property approximately centered within the one square mile area. Identify major streets within the square mile area and all streets that abut the subject property. Section, township, and range, north arrow, and the scale will be labeled.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

1. 2-06.4.7.A.1 - List as a general note: "Existing zoning is C-2."

2. 2-06.4.7.A.2 - List the gross area of the site/subdivision by square footage and acreage.

3. 2-06.4.7.A.4 - Identify the existing and proposed use of the property as classified per the UDC. List all UDC sections applicable to the proposed uses.

2-06.4.8 - Existing Site Conditions
The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided.

4. 2-06.4.8.A - Provide site boundary information, including bearing in degrees, minutes, and seconds, together with distances in feet, to hundredths of a foot, or other functional reference system.

5. 2-06.4.8.C - The following information regarding existing private or public right-of-way adjacent to or within the site shall be provided: the name, right-of-way width, recordation data, type and dimensioned width of paving, curbs, curb cuts, and sidewalks.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

6. 2-06.4.9.F - All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined.

7. 2-06.4.9.H.5.a - Per ICC A117.1, Section 502.5 Floor Surfaces. Parking spaces and access aisles shall comply with Section 302 and have surface slopes not steeper than 1:48 (2%). Access aisles shall be at the same level as the parking spaces they serve. Per ICC A117.1, Section 502.4.3 Access aisles shall extend the full length of the parking spaces they serve. That said detail 9 sheet AS2 does not work and the ramp will need to be located outside of the access aisle.

If you have any questions about this transmittal, please contact Elisa Hamblin, Elisa.Hamblin@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
02/24/2021 ANDREW CONNOR LANDSCAPE REVIEW Approved
03/01/2021 JPEELDA1 FIRE REVIEW Approved
03/03/2021 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change DATE: March 3, 2021 Returned for Corrections

PERMIT/ACTIVITY: DP21-0025
DESCRIPTION: SITE - CVS Pharmacy - 2601 S. Houghton Road, parking lot upgrades.

FEE BALANCE: $0 (zero) Thank you for the payment.

RESUBMITTAL
Submit the following documents to:
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
(Select "Existing Application", then the permit number)
1) Comment Response Letter
(your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

- Title the documents for your 2nd submittal starting with the
submittal number, for example: 2_Plan_Set

SEE REVIEW COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews - click on Review Details
- Documents - click on View to the right of each document

For all NEW development package submittals on the new Filedrop page, select the box: "SITE REVIEW...".

Thank you.