Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP21-0018
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/17/2021 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 05/17/2021 | ELISA HAMBLIN | ZONING | REVIEW | Approved | Approved Consolidation Request Form or letter from Pima County Assessor was not submitted. Zoning will approve, but a hold will be placed on the Certificate of Occupancy for building permit T21CM01954. |
| 05/17/2021 | AWARNER1 | LANDSCAPE | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Planning and Development Services Department, Plans Coordination FROM: Anne Warner, PLA PDSD Landscape/Native Plant Preservation Ordinance Review Section PROJECT: DP21-0018 Address: 1019 W PRINCE RD Zoning: C-1 Existing Use: Previously disturbed vacant lot Proposed Use: City of Tucson Fire Station #8 TRANSMITTAL DATE: May 12, 2021 DUE DATE: June 8, 2021 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Landscape/NPPO Review Section comments were addressed. This plan has been reviewed for compliance with applicable development criteria in the Unified Development Code (UDC) Administrative Manual (AM) Section 2-11, City of Tucson Uniform Development Code (UDC) Article 7.7 Native Plant Preservation, 7.6 Landscaping and Screening, and the UDC Technical Standards Manual (TSM). 1. UDC 2-10.4.1 Identification and Descriptive Data A. All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan. 2. A large existing mesquite (northeast area of property) is not included in the Native Plant Inventory, please include explanation regarding the tree. If it is to be removed, please note on both Native Plant Preservation plan and the Landscape Plan. If it requires mitigation, please revised Plant Inventory. 3. One canopy tree per four parking spaces is required, not ten, please revise calculations, UDC 7.6.4.B.1.a. 4. Please relocate trees to parking islands in order to provide as much shade in the parking areas as possible, UDC Technical Standards Manual 5-01-.3.2. 5. Four trees are required along the Prince Road street frontage, please provide them or apply for a Design Development Option, https://www.tucsonaz.gov/files/pdsd/2019_DDO_for_Landscape_Screening_UDC.pdf 6. Please add Backflow Prevention Unit detail to Irrigation Detail sheet. If you have any questions, please contact me at anne.warner@tucsonaz.gov or (520) 837-4969. |
| 05/24/2021 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | Email sent from: COTDSDPermits To: Gerrald, Terry, Amber Mon 5/24/2021 10:03 AM Returned for Corrections Notice - See review comments by Landscape PERMIT/ACTIVITY: DP21-0018 DESCRIPTION: Site/Grading/SWPPP - City of Tucson Fire Station No. 8, new construction. 1025 W PRINCE RD FEES DUE: $ 2,213.68 We await your submittal of the City of Tucson memo with information to process this payment. The memo may be submitted to us with your next submittal documents to the Filedrop, or by itself to: COTDSDpermits@tucsonaz.gov. Thank you. INCLUDE IN YOUR RESUBMITTAL 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Plan Set (all pages, full set, even if no changes were made) 3) Any other documents requested by review staff Please title your 4th submittal documents according to this example: 4_Comment Response Letter, 01.01.21 FILEDROP https://docs.tucsonaz.gov/Forms/tucsonpermitapp (Select "Existing Application", then enter the permit number) SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab - Reviews - click on REVIEW DETAILS - Documents - click on VIEW Sharon Beasley, Permit Specialist City of Tucson, Planning and Development Services Email for Development Pkgs: COTDSDpermits@TucsonAz.gov Email for Building Permits: PDSDinquiries@TucsonAz.gov |