Permit Number: DP21-0017
Parcel: 10818003B

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP21-0017
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/22/2021 SBEASLE1 START PLANS SUBMITTED Completed
02/19/2021 STEVE SHIELDS ZONING REVIEW Reqs Change FROM: Development Services Department Zoning Review

PROJECT: Choice Greens - Patio Expansion
Development Package (1st Review)
DP21-0017

TRANSMITTAL DATE: February 19, 2021

DUE DATE: February 22, 2021

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is January 21, 2022.

CONTENT REQUIREMENTS

1. COMMENT: 2-06.4.1 – Provide the name, mailing and email addresses, and phone number of the primary property owner of the site, the developer of the project, registrant(s), and other person(s), firm(s), or organization(s) that prepared the development package documents shall be provided on the right half of the cover sheet.

2. COMMENT: 2-06.4.2.D - The page number and the total number of pages in the package (i.e., sheet xx of xx) shall be provided in the title block.

3. COMMENT: 2-06.4.3 – Provide the development package case number, DP21-0017, adjacent to the title block on all sheets.

4. COMMENT: 2-06.4.3 – Provide the following DP case numbers adjacent to the title block on all sheets, DP15-0181 & DP17-0136.

5. COMMENT: 2-06.4.4 - The project-location map shall be drawn at a minimum scale of three-inch equals one mile.

6. COMMENT: 2-06.4.4.B - Identify major streets and regional watercourses within the square mile area and all streets that abut the subject property on the location map.

7. COMMENT: 2-06.4.4.C – The section corners; north arrow; and the scale will be labeled on the location map.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

8. COMMENT: 2-06.4.7.A.1 - List as a general note: "Existing zoning is C-1."

9. COMMENT: 2-06.4.7.A.2 - List the gross area of the site/subdivision by square footage and acreage.

10. COMMENT: 2-06.4.7.A.4 - Identify the existing and proposed use of the property as classified per the UDC. List all UDC Use Specific Standards that apply to the uses.

11. COMMENT: 2-06.4.7.A.6.a – As River Rd. is designated as an Arterial Scenic route on the COT MS&R map provide a general note on the cover sheet stating “THIS PROJECT IS DESIGNED TO MEET THE OVERLAY ZONE(S) CRITERIA, UDC ARTICLE 5.3 SCENIC CORRIDOR ZONE (SCZ) & UDC ARTICLE 5.4 MAJOR STREETS AND ROUTES SETBACK ZONE (MS&R).”

2-06.4.7.A.8 - For development package documents provide:

12. COMMENT: 2-06.4.7.A.8.c – Provide a use area expansion calculation on the plan based on the two DP listed above.

If you have any questions about this transmittal, please contact Elisa Hamblin, (520) 837-4966 or Elisa.Hamblin @tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
02/23/2021 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change 4.1 Identification and Descriptive Data

ADMINISTRATIVE MANUAL

4.1 Identification and Descriptive Data

The Development Package will contain the following identification in the lower right corner of each sheet:

Any other relevant case number for reviews or modifications that affect the site.

Add case number and DP21-0017 on each sheet.

Ensure that Zoning comments are addressed prior to landscape section approval.
03/01/2021 JPEELDA1 FIRE REVIEW Approved
03/01/2021 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change DATE: March 1, 2021
Returned for Corrections

PERMIT/ACTIVITY: DP21-0017
DESCRIPTION: SITE - Choice Greens restaurant.

FEE BALANCE: $0 (zero) Thank you for the payment.

RESUBMITTAL
Submit the following documents to:
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
(Select "Existing Application", then the permit number)

1) Comment Response Letter
(your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

- Title the documents for your 2nd submittal starting with the
submittal number, for example: 2_Plan_Set

SEE REVIEW COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews - click on Review Details
- Documents - click on View to the right of each document

For all NEW development package submittals on the new Filedrop page, select the box: "SITE REVIEW..." for quicker processing.

Thank you.

City of Tucson
Attn: Sharon Beasley, Permit Specialist
Planning and Development Services
email: COTDSDPermits@TucsonAz.gov