Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP21-0001
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/05/2021 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 03/12/2021 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Reqs Change | DP21-0001 1) Sheet 2. Provide a detail for plan note 11. Grades at each corner and confirm that utility box is pedestrian rated. 2) Show on plans that the sidewalk along Melville ave will be constructed to PAG detail 200. Provide spot grades at 20' intervals along its length to show ADA compliance. 3) Show on plans that the curb access ramp at the southern end of Melville will meet PAG detail 207 4) At the pedestrian circulation connection to the new sidewalk along Melville show a 5'x5' landing 5) Provide a detail showing where the pedestrian path crosses the north entrance point. How the path enters the curbed landscaped area 6) Northern circulation path crosses over several vehicle wheel stops. Show how these will be removed or adjust path as needed. 7) Where the pedestrian path on the north side turns south, provide physical separation between the pedestrian path and vehicle use area 8) Concrete re-construction detail on sheet 2, does not provide enough information, dimensions or grades to show that it meets ICC ADA compliance standards for, cross slope, running slope, landing area etc. please revisit this detail 9) For the proposed pedestrian circulation path, show on plans cross slope and running slope 10) Sheet 2. Just east of the accessible parking spaced, there appears to be a door or gate at the top of a curb access ramp. Provide a detail showing how this meets ADA maneuvering and access details in ICC A117 2009 11) Sheet 3 section A-A does not match dimensional sheet 2 or sheet 3 plan view. The extruded curb is shown as a fence, and the landscape buffer width is incorrect. Update as needed 12) Previous comment 10, provide spot grades for water harvesting basins to ensure that 9" of depth is being provided. 13) Update plans to show that no new structure or storages units will be placed within the erosion hazard setback for the Alamo Wash 14) Show in the drainage statement the erosion hazard calculation using a curved section of wash. The CFS value does not align with values shown in the TSMS system which range from 2275 cfs to 2818. Supply a sealed drainage statement on next submittal 15) Update site plan in drainage statement to match new site plan 16) A meeting is requested to discuss the proposed pedestrian circulation path prior to the next submittal John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov |
| 03/30/2021 | SBEASLE1 | PIMA COUNTY - ADDRESSING | PIMA COUNTY - ADDRESSING | Approved | 03/30/21 Right Space Storage, DP21-0001 , 2nd submittal is Approved by Pima County Addressing. Thank you, Robin Freiman, Addressing Official Pima County Development Services Department 201 N Stone AV – 1st Floor Tucson, AZ 85701 (520) 724-7570 |
| 04/06/2021 | ANDREW CONNOR | LANDSCAPE | REVIEW | Reqs Change | Ensure that Zoning, Engineering comments and concerns are addressed prior to landscape section approval. Additional comments may apply |
| 04/07/2021 | AWARNER1 | ZONING | REVIEW | Approved | |
| 04/08/2021 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | DATE: April 8, 2021 Returned for Corrections PERMIT/ACTIVITY: DP21-0001 DESCRIPTION: SITE - Right Space Storage Addition. New private self storage units and landscape buffer. 6444 E BROADWAY BL FEE BALANCE: $0 (zero) Thank you for the payment. RESUBMITTAL Submit the following documents to: https://docs.tucsonaz.gov/Forms/tucsonpermitapp (Select "Existing Application", then the permit number) 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Plan Set (all pages, full set, even if no changes were made) 3) Any other documents requested by review staff - Title your 3rd submittal documents according to this example: 3_Comment Response Letter, 01.01.21 SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab - Reviews - click on Review Details - Documents - click on View to the right of each document Thank you. Sharon Beasley Permit Specialist City of Tucson Planning and Development Services email: COTDSDPermits@TucsonAz.gov (Disregard the automatic reply you will receive: "This email account is not...") |