Permit Review Detail
Review Status: Completed
Review Details: DEV PKG
Permit Number - DP20-0241
Review Name: DEV PKG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/06/2021 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | ADMINISTRATIVE MANUAL 4.1 Identification and Descriptive Data The Development Package will contain the following identification in the lower right corner of each sheet: Any other relevant case number for reviews or modifications that affect the site. Add case number and DP20-0241 on each sheet. Ensure that Zoning comments are addressed prior to landscape section approval. |
| 01/12/2021 | JPEELDA1 | FIRE | REVIEW | Approv-Cond | Access to the building exceeds the 150' but after further review we are within 300' of a hydrant and we should be able to turn around after the gate. Gate shall be 20' wide so that we can get a fire engine back there. |
| 01/25/2021 | ALEXANDRA HINES | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department FROM: Nicholas Martell, Planner PDSD Zoning Review Section PROJECT: DP20-0241 Development Package (1st Review) DP20-0241 TRANSMITTAL DATE: 1/25/2021 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is November 25, 2021. 2-06.3.0 FORMAT REQUIREMENTS 1. 2-06.4.1 - Provide the email addresses of the primary property owner of the site, the developer of the project, registrant(s), and other person(s), firm(s), or organization(s) that prepared the development package documents in each title block. 2. 2-06.4.2.D - Provide consistent page numbering for all pages of the DP. Pages 3 and 4 should be labeled as such. 3. 2-06.4.3 - Provide assigned case number DP20-0241 adjacent to the title block on each sheet. 4. 2-06.4.4.A - Please center the project site in the location map in the top right corner of page 1. 5. 2-06.4.7.A.4 - Commercial and Industrial are the use groups mentioned in plan note 3. This standard requires the developer to "Identify the existing and proposed use of the property as classified per the UDC. List all UDC sections applicable to the proposed uses." Please add the uses (i.e. office, manufacturing) to the general note along with any use specific standards applicable. 6. 2-06.4.7.A.6.a - As a general note provide the type of application processed or overlays applicable, a statement that the project meets the criteria/conditions of the additional application or overlay, the case number, date of approval, what was approved, and the conditions of approval, if any. This site contains the following overlays: DM AFB Approach Departure Corridor, AEZ Land Use, DM AFB Noise Control, AEZ Height zone. 7. 2-06.4.8.A - Ensure the site boundary perimeter information, including bearing in degrees, minutes, and seconds, with basis for bearing noted, together with distances in feet, to hundredths of a foot, or other functional reference system are provided for every boundary. 8. 2-06.4.9.Q - Add the specific use within the footprint of the proposed building. The use information can be added within the building drawing on the site plan on page 1. 9. 2-06.4.9.T - Note 20, regarding solid waste collection is noted, however, the refuse collection areas, locations of dumpsters, screening location and materials, and vehicle maneuverability, fully dimensioned, and access route must be added to the Development Package. Refer to Section 8-01.0.0 of the Technical Standards Manual. If you have any questions about this transmittal, please contact Nicholas Martell at Nicholas.Martell@tucsonaz.gov. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Development Package |
| 01/26/2021 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | DATE: January 26, 2021 Returned for Corrections / Request for Resubmittal PERMIT/ACTIVITY: DP20-0241 DESCRIPTION: SITE/GRADING - Customs and Border Patrol Modular, addition of a building and site work to existing building. FEES DUE: $ 1,206.50 Please pay the total fees (or at a minimum, the REVIEW Fees). A payment is required before your resubmittal. ONLINE PAYMENT https://www.tucsonaz.gov/pdsd/fees PLEASE READ: If information is not available or amount isn't correct, check back in a few hours after data is updated. (Visa, MC, Discover, American Express, or pay from bank account) 1- Click on: Pay Planning & Permit Fees 2- Enter your Permit Nbr, example: dp20-0000 (not case-sensitive but a hyphen-dash- is needed) 3- Business/Individual Name: Leave blank 4- Click the blue tab: Continue 5- Under the Pay column, check the boxes you want to pay 6- Click Continue, then enter your credit card info 7- If any issues, try using the browser Internet Explorer RESUBMITTAL OF UPDATED/CORRECTED DOCUMENTS Submit documents to NEW FILEDROP: https://docs.tucsonaz.gov/Forms/tucsonpermitapp Select "Existing Application", then the permit number 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Plan Set (all pages, full set, even if no changes were made) 3) Any other documents requested by review staff - Title the documents for your 2nd submittal starting with the submittal number, for example: 2_Plan_Set SEE REVIEW COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab - Reviews - click on Review Details - Documents - click on View to the right of each document FYI - For all NEW development package submittals in the future (not resubmittals) on the Filedrop page, select the box: "SITE REVIEW...". Thank you. City of Tucson Attn: Sharon Beasley, Permit Specialist Planning and Development Services email: COTDSDPermits@TucsonAz.gov |
| 12/04/2020 | SBEASLE1 | ENGINEERING | REVIEW | Approved | Approved by Loren Makus during OK to Submit, 12/03/20. |
| 12/04/2020 | SBEASLE1 | PIMA COUNTY - ADDRESSING | PIMA COUNTY - ADDRESSING | Passed | 12/04/20 ATTN APPLICANT: The project will require building numbers for the existing and proposed structures. This project does not require review by Pima County Addressing. Nicholas Jordan, Addressing Specialist Pima County Development Services Department 201 N Stone AV – 1st Floor, Tucson, AZ 85701 (520) 724-9623 |
| 12/04/2020 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 12/21/2020 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed |